Shaft Stirrers

Compare Tool

Select up to 3 products

HomeAll Products

Stirrers Shaft Stirrers

1 - 32 of 119
Sort
View
Show

Attention Thomas Scientific Customers

Due to the current pandemic, lead times for PPE items are longer than what is listed on our website. Please expect shipping delays of all PPE products during this time.

  • PTFE stir blades for button type stir shafts. 10mm OD shafts can be found in our product series 8068, 8070, 8074 and 8075. 19mm OD shafts can be found in our 8076 and 8077 series.

  • Polished Glass Stirrer Shafts

    Wilmad-LabGlass - SP Scienceware

    Precision ground and polished, these borosilicate glass stirrer shafts have a 10mm O.D. For use with LG-9475T bearing with PTFE bearing surface, or other bearings with a PTFE interface with the same bore. Features a side button at bottom for attachment of any of the stirrer/stirring blades (LG-9505…

  • Features: UL 61010-1, CSA C22.2 and CE certified (available by request, additional cost) Filter reactors for single or multi-step reactions and filtrations in the same vessel, they also eliminate material transfers and reduce losses. Modular filter assembly can be easily detached for…

  • Thomas No. 1177M38 Impeller. Mixer. Blade. Crossed Blade. Radial Flow. High Speed. Low Viscosity. 316L SS. Electropolished. High Shear. High Vortexing. Thomas No. 1177M39 This radial flow impeller is effective for high speed, low viscosity mixing. The 50 mm (2”) diameter…

  • Thomas No. 1198F83: Stirring shaft with floating blades: The two blades that open as the speed rises generate an axial flow in the container, from the top towards the bottom. Particularly recommended for stirring in narrow-neck containers, e.g. flasks. Thomas No. 1198F84: Stirring shaft with…

  • The unique design of our Tru-Stir™ stirrer shaft coupling eliminates the need to use rubber hose or universal adapters to attach your stirrer shafts to overhead stir motors. Coupling incorporates a unique helical stainless steel spring permitting up to 1/4” of offset misalignment and…

  • For use with Flask Head 9443. By using precision bore tubing throughout the length of the bearing, a stirrer is produced that will hold to within 1mm of vacuum and withstand pressures in the flask up to 300mm. The 9532 Agitator, used with this bearing actually develops a negative pressure of 230mm…

  • Stirrer Shafts

    Chemglass

    Precision ground and polished stirrer shaft for use with Chemglass process reactors. Designed to utilize CG-2095 and CG-2096 PTFE agitators. Lower portion of stirrer shaft is sandblasted and has a 3/8” wide flat.  Please Note: CG-2097-75 and CG-2097-100 are made from heavy wall tubing…

  • Teras Turbine™

    Foxx Life Sciences

    Next Generation Mixing Technology from Foxx Life Sciences. The Teras Turbine™ has four mixing modes: Top Anaerobic, Top Aerobic, Full Mixing, and Bottom Mixing. Top Anaerobic is ideal for mixing of less viscous material at the top of the carboy or bottle. Top Aerobic is for adding air…

  • Agitators are made entirely of PTFE and glass filled PTFE and are for use with 10mm OD stirrer shaft CG-2075-B. Available in 45°, 60° and 90° impeller angles. The 45° and 60° impellers are set up to stir downwards in a clockwise direction and upwards when rotated…

  • Agitators are made entirely of PTFE and glass filled PTFE and are for use with 19mm or 25.4mm OD stirrer shaft CG-2097 and are available in 45°, 60° and 90° impeller angles. The 45° and 60° impellers are set up to stir downwards in a clockwise direction and upwards when rotated…

  • 4 Blade PTFE agitator available with either 45 or 90 degree blade angle. For use with glass or metal shafts and is secured using a compression style fitting allowing it to positioned anywhere along the length of the shaft.

  • 16mm O.D. shaft is constructed using a molding process whereas the blade is molded directly onto the PTFE coated stainless steel shaft. This makes the stirrer chemically inert, easy to clean and can be used up to 280°C. The top of the shaft has 50mm of exposed 1/2" diameter stainless steel…

  • Support Stand was designed to accommodate vessels up to 10" diameter, to sit close to the support rod. Support rod is ideal for mounting stirring motors. Each of the four corners rests on a rubber cushion. The powder coated steel base measures 7.875” (200mm) W x 12.5" (316mm) deep…

  • Replacement components for CLS-1414 and CLS-1415 Spinner Flasks.The Complete Impeller Assembly consists of top cap, silicone liner, glass rod, compression fitting magnet holder, paddle and magnetic stir bar.

  • Mixing Shafts

    Oakton

    Shafts are 316 stainless steel. All 3/8" (9.5 mm) dia shafts are machined on one end to accept a 5/16" (8 mm) bore diameter propeller.

  • A 10mm precision ground stirrer shaft to fit CG-2070 through CG-2072 10mm bearings. Side button for attachment of CG-2080 or CG-2081 PTFE stirrer blades. PLEASE NOTE: THESE SHAFTS ARE NOT TO BE USED WITH ANY TYPE OF PTFE BEARING.  FOR POLISHED SHAFTS USED WITH PTFE BEARINGS SEE CG-2079.

  • 10mm O.D. shaft is constructed using a molding process whereas the blade is molded directly onto the PTFE coated stainless steel shaft. This makes the stirrer chemically inert, easy to clean and can be used up to 280°C. The top of the shaft has 50mm of exposed 1/4" diameter stainless steel…

  • Precision bore bearing for use in moderate vacuum with a CG-2074 or CG-2075 ground 10mm stirrer shaft. NOTE: Not for use with CG-2078 or CG-2079 polished stirrer shafts.

  • Eliminates Flask Breakage: PTFE is the only contact in the lower radius of the flask, therefore breakage due to dropping the stirrer shaft has been eliminated. Eliminates the Frustration of Assembly: Unique design permits the proper amount of tension to be applied to the blade,…

  • Chlorofluorocarbon grease for use at speeds up to 6000 r.p.m. with ACE standard glass assemblies. Use 8040 water-cooled type bearing for long-time stirring (over one hour). Below one hour, 8038 type may be used at 1500 r.p.m.; eight hours at 1000 r.p.m. High chemical inertness unaffected by strong…

  • Polished stainless steel stirring shafts, 10mm OD, drilled type with removable button. When used with 8066 PTFE bearing, a lubricant-free vacuum seal can be realized at speeds up to 200 rpm. Recommended for use with 8044,8050,8066,13443 and 13445 bearings. With button, shaft accepts…

  • Propellers

    Oakton

    Use these three-bladed electro-polished propellers for your general-purpose mixing. Use singly or mount several on a shaft for thorough agitation. Choose marine-style propellers for your general-purpose mixing or choose turbine style for your airless mixing in deep containers. Dispersion…

  • Shaft is precision ground and polished to fit our CG-2077-H, CG-2077-G and CG-2077-U style 10mm PTFE bearings. Designed to be used with cylindrical type reactors. The curved glass blades are spaced 120° apart and angled upward. PLEASE NOTE: STIRRER SHAFTS ARE DESIGNED FOR CLOCKWISE ROTATION.

  • Polished glass stirring shafts, 19mm OD. Available in solid and hollow styles and in various lengths. Join 8085 blades to button type shafts, Join 8091,8092,8093 and 8100 agitators to either knob or drilled style shafts. Join all shafts to stirrer motor using 8124 series chucks. Recommended for use…

  • PTFE agitator with removable blade secured with a PTFE pin. Supplied 3.2x15.2cm blade will fit through a 45/50 joint. Fits 19mm od drilled type or knob type 8076, 8078 & 8079 shafts.

  • Precision PTFE Stirrer Bearings

    Wilmad-LabGlass - SP Scienceware

    Uniquely designed and lubricant free, these precision stirrer/stirring bearings are self-aligning. The saddle O-ring provides constant force and a positive seal on the stirring rod that allows vacuum operation to as low as 1mm. Ground finish rods from other manufacturers are not recommended for use…

  • Stirrer Bearings

    Chemglass

    Grease-Free PTFE stirrer bearing for use under moderate vacuum. The bearing consists of a PTFE standard taper body, Nylon compression cap, PTFE Insert/bushing and a Nylon loosening nut. The PTFE insert/bushing provides only glass and PTFE contact with the reaction. Loosening nut above the standard…

  • A 10mm OD precision ground and polished stirrer shaft with our patented** Chem-Stir™ blade attachment system. Shaft (C) has been manufactured with a ring at the lower end to permit attachment of the blade (B) with a PTFE nut (D) and bolt (A). Shaft is supplied complete with PTFE nut and bolt…

  • PTFE oval stir blades for 10mm OD button type stir shafts. 10mm OD shafts can be found in our 8068, 8070, 8074 and 8075 series.

  • Polished glass stirring shafts, 10mm OD. Recommended for use with only our 8050,8066,13443 and 13445 bearings. Join 8083,8085,8086,8087,8096 blades to button type shafts. Join 8088, 8089, 8090 & 8091 agitators to bead type shafts. Plain shafts will accept 8094 & 8095 agitators secured with a…

  • Button type, solid glass stirring shafts, 5 & 6mm OD. Precision ground shafts, codes -04 & -06, should be used in matching glass Trubore 9524 and 9527 bearings. Polished shaft, code -40, should be used only in our 8066-120, 6mm PTFE inner bearing. All accept our 9542 blades. Join to stirrer motor…