TLC Plates
-
Thin-layer chromatography (TLC) plates for adsorption, partition, and ion-exchange techniques. Six media choices with glass, polyester, and aluminum backings. Silica-based adsorbent layers in Sigma-Aldrich TLC plates incorporate a polymeric binder; highly purified silica gel plates incorporate a…
-
Legal Information Aldrich is a registered trademark of Sigma-Aldrich Co. LLC
-
These plates allow users to quickly and easily apply any kind of sample, even large volumes of diluted samples. EMD Milliporeconcentrating zone plates are based on different adsorption properties of two adsorbents. The first is a large pore concentrating adsorbent where the samples are applied; the…
-
Reversed Phase Octadecyl Silanized Silica Gel UNIPLATES
Miles Scientific (Analtech)These reversed phase TLC plates have been manufactured to be greater than 50% and less than 100% silanized. Because of this they are hydrophobic, but wettable. Features: 14% carbon content Acid stable (UV254) fluorescent indicator Glass backing 250um coating thickness 25…
-
Alox Aluminium Oxide Layers for TLC
MACHEREY-NAGELAluminium oxide, specific surface (BET) ~ 200 m 2 /g, mean pore size 60 Å; inert organic binder indicator manganese-activated zinc silicate available as glass plates, POLYGRAM® polyester sheets and ALUGRAM® aluminium sheets Recommended application: terpenes, alkaloids,…
-
TLC Aluminium Oxide 60 F254, Basic
MilliporeSigmaAluminiumoxide plates are used to analyze basic and neutral compounds at different pH levels. Depending on the pH range in question, professionals can choose between two kinds of aluminum oxide plates. Under aqueous conditions, basic aluminum oxide plates are best for separating basic compounds,…
-
These plates allow users to quickly and easily apply any kind of sample, even large volumes of diluted samples. EMD Milliporeconcentrating zone plates are based on different adsorption properties of two adsorbents. The first is a large pore concentrating adsorbent where the samples are applied; the…
-
-
TLC Kieselguhr F254
MilliporeSigmaPrecoated Kieselguhr or mixed Silica gel/Kieselguhr plates are only of small importance nowadays. Kieselguhr layers are used like cellulose layers for the TLC separation of polar and moderately polar substances. Polyamide, on the other hand , is used for the separation of flavonoids and other…
-
SIL G Unmodified Standard Silica Layers for TLC
MACHEREY-NAGELSilica 60, specific surface (BET) ~ 500 m 2 /g, mean pore size 60 Å, specific pore volume 0.75 mL/g, particle size 5–17 µm; standard grade Thickness of layer for analytical plates 0.25 mm, for preparative plates 0.5 and 1 mm For 2 mm preparative layers a slightly coarser…
-
TLC SILICA GEL 60 W F254S 25 GLASS PLATES 20 X 20 CM
MilliporeSigmaEMD Millipore classical silica TLC plates are based on a combination of proven EMD Millipore silica gel 60 and the addition of a unique polymeric binder resulting in a very adherent and hard surface that will not crack or blister and even allow writing with a pensil on the surface without risk to…
-
TLC Silica gel 60 F254
MilliporeSigmaClassic silica TLC plates are based on a combination of proven EMD Millipore silica gel 60 and the addition of a unique polymeric binder resulting in a very adherent and hard surface that will not crack or blister and even allow writing with a pensil on the surface without risk to damage the layer.
-
HPTLC CELLULOSE F 25 GLASS PLATES 10 X 10 CM
MilliporeSigmaCellulose plates are used to analyze polar substances. An organic sorbent, cellulose is perfect for separating hydrophilic substances by partition chromatography. Typical applications include the analysis of amino acids, carbohydrates, and phosphates as well as nucleic acid and nucleic acid…
-
TLC Silica Gel 60 F254 GLP
MilliporeSigmaThese plates feature individual laser coding for GLP applications. Designed for GLP applications, the tops of each of these plates bear an item, batch, and individual plate number. As a result, lab professionals can easily record and archive every plate they use. Based on proven EMD Millipore…
-
HPTLC silica gel 60
MilliporeSigmaHPTLC plates deliver fast and quantitative analysis of complex samples for manual or automated use. EMD Millipore’s HPTLC silica plates work three times faster than conventional TLC plates – and they’re more sensitive. The particle sizes range in HPTLC is between 4-8µm, which creates a smoother…
-
Features High purity silica 60 with gypsum and a very small quantity of a polymeric organic binder softer than the standard silica layer, i. e. spots can be scratched and the layer absorbs faster Available as glass plates with or without fluorescent indicator Recommended for the…
-
TLC Silica Gel 60 F254 with Concentrating Zone 20 x 2.5 cm
MilliporeSigmaThese plates allow users to quickly and easily apply any kind of sample, even large volumes of diluted samples. EMD Millipore concentrating zone plates are based on different adsorption properties of two adsorbents. The first is a large pore concentrating adsorbent where the samples are applied;…
-
Nano-DURASIL Unmodified HPTLC Silica Layers
MACHEREY-NAGELFeatures Nano silica 60, specific surface (BET) ~ 500 m2/g, mean pore size 60 Å, specific pore volume 0.75 mL/g, particle size 2–10 µm Indicator: manganese activated zinc silicate with green fluorescence for short-wave UV (254 nm) Hard, water-resistant and wettable…
-
TLC Silica gel 60 F254
MilliporeSigmaEMD Millipore classical silica TLC plates are based on a combination of proven EMD Millipore silica gel 60 and the addition of a unique polymeric binder resulting in a very adherent and hard surface that will not crack or blister and even allow writing with a pensil on the surface without risk to…
-
Baker-flex® Coated TLC Aluminum Oxide Sheets
Avantor - J.T.Baker®Ready-to-use plastic sheets, 50 x 200 mm or 200 x 200 mm, with absorbent coating, which is abrasion-resistant and highly uniform; are easily cut to desired size and allow sample fraction to be cut rather than scraped The silica gel and aluminum oxide sheets have coating approximately 200 microns…
-
HPTLC Silica gel 60 F254
MilliporeSigmaPlates deliver fast and quantitative analysis of complex samples for manual or automated use. EMD Millipore’s HPTLC silica plates work three times faster than conventional TLC plates – and they’re more sensitive. The particle sizes range in HPTLC is between 4-8µm, which creates a smoother surface…
-
TLC Kieselguhr F254
MilliporeSigmaPrecoated Kieselguhr or mixed Silica gel/Kieselguhr plates are only of small importance nowadays. Kieselguhr layers are used like cellulose layers for the TLC separation of polar and moderately polar substances. Polyamide, on the other hand , is used for the separation of flavonoids and other…
-
Nano-SIL NH2 Amino-Modified HPTLC Silica Layers
MACHEREY-NAGELFeatures Base material: nano silica 60, specific surface (BET) ~ 500 m2/g, mean pore size 60 Å, specific pore volume 0.75 mL/g particle size 2–10 μm pH stability 2–8 Indicator: acid-resistant product with a pale blue fluorescence for short-wave UV (254…
-
HPTLC Silica gel 60 RP-18
MilliporeSigmaRP modified plates serve two purposes: act as a pilot method for HPLC and allow to choose various solvent system for special separations. RP-modified silica layers from EMD Millipore are well suited for many separation challenges that unmodified silica cannot overcome. These layers use aqueous…
-
Glass TLC Plates
MilliporeSigmaFor thin layer and preparative layer chromatography Ready-to-use Layer thickness 0.25 mm Allow safe spotting without layer damage Plates have a uniform, abrasion-resistant coating and a patented, inert, hard-layer binder that is chip and abrasion-resistant. F254 is a…
-
Corning® 96 Well Strip Ejector
CorningDesigned to remove Stripwell™ strips from the egg crate holder
-
TLC Cellulose
MilliporeSigmaCellulose plates are used to analyze polar substances. An organic sorbent, cellulose is perfect for separating hydrophilic substances by partition chromatography. Typical applications include the analysis of amino acids, carbohydrates, and phosphates as well as nucleic acid and nucleic acid…
-
HPTLC SILICA GEL 60 RP-18 W 25 GLASS PALTES 10 X 20 CM
MilliporeSigmaRP modified plates serve two purposes: act as a pilot method for HPLC and allow to choose various solvent system for special separations. RP-modified silica layers from EMD Millipore are well suited for many separation challenges that unmodified silica cannot overcome. These layers use aqueous…
-
TLC SILICA GEL 60 W F254S 25 ALUMINIUM SHEETS 20 X 20 CM
MilliporeSigmaEMD Millipore classical silica TLC plates are based on a combination of proven EMD Millipore silica gel 60 and the addition of a unique polymeric binder resulting in a very adherent and hard surface that will not crack or blister and even allow writing with a pensil on the surface without risk to…
-
Prepared by hydrolysis of high purity cellulose with HCl mean degree of polymerization 40–200 Available as glass plates and POLYGRAM® polyester sheets Recommended application: carboxylic acids, lower alcohols, urea and purine derivatives
-
Baker-flex® Coated TLC Cellulose Sheets
Avantor - J.T.Baker®Ready-to-use plastic sheets, 50 x 200 mm or 200 x 200 mm, with absorbent coating, which is abrasion-resistant and highly uniform; are easily cut to desired size and allow sample fraction to be cut rather than scraped The silica gel and aluminum oxide sheets have coating approximately 200 microns…
