PerkinElmer ICP-MS
-
The D-Torch is a revolutionary new demountable torch design with interchangeable outer Tubes. Quartz outer Tubes are ideal for most aqueous samples, while ceramic outer Tubes last longer for samples with high dissolving solids or for organic applications, such as wear metals in engine oils.
-
The GemCone low-flow nebulizer permits lower nebulizer flow rates, useful for spectral lines with high excitation energies and for providing a more robust plasma. The nebulizer is optimized for low nebulizer gas flow for use with cyclonic spray chambers. It requires an end cap (N0680504) for use…
-
Fused Silica Obstruction Removal Kit for ST type Nebulizers. Used to clear blockage from ST type nebulizers. Inc Features and Benefits Pure Grade Standards for AA and ICP-OES Analyzed by ICP-OES Analyzed by Classical Wet Assay 32 trace impurities analyzed by ICP-MS of the final…
-
Consumables Kit for ELAN DRC-e/9000
PerkinElmerThis kit includes: ELAN Cross-Flow Nebulizer Tip Kit, Qty. 1 (N8120515) 0-Slot Quartz Torch, Qty. 1 (N8122006) 2.00 mm I.D. Alumina Injector, Qty. 1 (N8126041) Nickel Skimmer Cone, Qty. 2 (WE021137) Nickel Sampler Cone, Qty. 2 (WE021140) Sampler Cone O-Ring, Qty. 5 (WE012687) Series II…
-
Demountable design using one-piece quartz tubing for plasma and auxiliary gas flow. The torch operates at 25% reduced argon gas flows compared to the standard demountable quartz torch (N8122006). The High Efficiency Quartz Torch Installation Kit (W1007468) is required for first-time installations…
-
The PC 3 is a small, robust Peltier cooled cyclonic spray chamber. The PC 3 offers the advantages of low memory effects, constant temperature, fast rinse-out, and high sample transport efficiency. The cooled outer walls of the PC 3 spray chamber enhance long-term signal stability, reduce…
-
Low-Flow GemCone for Optima 3X00 Nebulizer
PerkinElmerCan be used with either the glass Cyclonic spray chamber or the Ryton ® MEINHARD ® end cap. RequiresMEINHARD ® End Cap II, P/N N0680504, when used with the Ryton ® double-pass, Scott-type spray chamber(glass or Ryton).
-
Replacement connector and sample tubing for glass concentric nebulizers with EzyFit sample inlet.
-
Viton O-Ring 44 mm I.D. for Optima 8x00
PerkinElmerThis o-ring replaces the obsolete o-ring N0777844.
-
ST3 MicroFlow PFA nebulizer
PerkinElmerThe ST3 MicroFlow PFA nebulizer has an exchangeable external sample uptake capillary. The sample uptake rate is controlled by the diameter of the external capillary or probe.
-
The SeaSpray Concentric Nebulizer is ideal for samples with high dissolved solids and offers outstanding nebulization effciency for trace level analysis. It offers freedom from clogging while nebulizing solutions near the limit of solubility of most mineral salts, and conferring signifcant…
-
MicroFlow nebulizers are resistant to clogging, reliably self-aspirated or pumped to produce a fine aerosol for high transport efficiency and high sensitivity. The PFA-ST3 Nebulizer is designated for superior clog resistance and higher sensitivity compared to the standard PFA nebulizer. • All PFA…
-
This baffled cyclonic spray chamber, made of quartz, is designed for all-purpose, non-hydrofluoric acid applications. It provides excellent sensitivity, stability and low blanks.
-
The SeaSpray ™ concentric nebulizer is ideal for samples with high dissolved solids and offers outstanding nebulization ef ciency for trace level analyses. It offers freedom from clogging while nebulizing solutions to the limit of solubility of most mineral salts and conferring significant…
-
This kit includes: 46 cm Copper Refrigeration Tube, Qty. 1 (W1038883) Brass Nut for 3.175 mm Swagelok Tube Fitting, Qty. 2 (WE011094) Brass Back Ferrule for 3.175 mm Swagelok Tube Fitting, Qty. 2 (WE011095) Brass Front Ferrule for 3.175 mm Swagelok Tube Fitting, Qty. 2 (WE011096) Coil Forming…
-
-
Adjustable Torch O-Ring Kit for Avio 200/500
PerkinElmerThis kit includes: O-Ring 20.3 mm I.D., Qty. 2 (09902223) O-Ring 2.57 mm I.D., Qty. 2 (N0791334) Plastic O-Ring Removal Pick, Qty. 1 (09220410)
-
The UniFit connector is a convenient drain connector for glass cyclonic spray chambers.
-
-
The PEEK Mira Mist ® nebulizer produces excellent mist and can handle high level of particulates in sample. Fits regular spray chambers as a direct replacement for glass concentric nebulizers. Its features include standard pressure (45 psi), low sample flow and enhanced parallel path design.
-
Demountable design using one-piece quartz tubing for plasma and auxiliary gas flow. Available in a wide range of styles from 0-slot to 3-slot torches, depending on instrument and application needs. Torches without slots are recommended for organic solvents. 1-slot torches are the standard torch for…
-
This kit includes: O-Ring 29.74 mm I.D., Qty. 1 (09902131) O-Ring 20.3 mm I.D., Qty. 2 (09902223) O-Ring 28.17 mm I.D., Qty. 1 (09921061) O-Ring 26.57 mm I.D., Qty. 1 (09921062) O-Ring 20.3 mm I.D., Qty. 1 (09902045)
-
The MicroMist micro-uptake glass concentric nebulizer offers high performance for limited sample volumes. MicroMists with sample uptakes 0.2 – 0.4 mL/min are fitted with a UniFit connector with 1.3 O.D. x 0.50 mm I.D. x 700 mm long sample tubing. MicroMists with sample uptakes 0.05 – 0.1 mL/min are…
-
EzyLok Kit for Glass Concentric Nebulizers
PerkinElmerIncludes: EzyLok Connector for 4mm Tubing EzyLok 6mm Hose Adaptor Nebulizer Hose Clip
-
SeaSpray U-Series Nebulizer 1mL/min
PerkinElmerMaterial: Borosilicate glass High physical reproducibility ~ 1%, TDS tolerance, typically up to 20%, High tolerance to particulates, typically up to 75um, Low RSD's due to highly accurate construction
-
200 uL/min self-asp capillary
PerkinElmer200 µL/min self-aspirating sample capillary for ST nebulizer. 0.30 mm i.d., yellow marker
-
This nebulizer adapter plug 16/6 is used with standard glass cyclonic spray chambers (N0776052) in Optima 2x00 DV, 4x00 DV, 5x00 DV, 7x00 DV, and 8x00 ICP-OES series instruments.
-
Cyclonic spray chamber drain fitting
PerkinElmerCyclonic spray chamber drain fitting with ETFE capillary tubing - 24 length by 0.030 ID x 0.062 OD.
-
Includes all O-Rings used in the Cross-Flow and Cross-Flow II nebulizers.
-
The D-Torch is a revolutionary new demountable torch design with interchangeable outer Tubes. Quartz outer Tubes are ideal for most aqueous samples, while ceramic outer Tubes last longer for samples with high dissolving solids or for organic applications, such as wear metals in engine oils.
-
This baffled micro cyclonic spray chamber, made of quartz, is designed for use with oil FAST and organics solvent applications. It features secure, leak-free threaded drain port, o-ring-free connections to the nebulizer and torch injector, internal baffle and threaded auxiliary port for addition…
-
Axial Flat Mirror Kit for Avio 200
PerkinElmerThe recommended axial flat mirror kit for use with the Avio 200 ICP-OES. Includes: mounted mirror with o-ring and one set of large nitrile gloves.