ICP-MS
-
GemClean Nebulizer
Agilent TechnologiesThe Agilent Technologies GemClean nebulizer is used for the ultra-trace analysis of aqueous, HF acid, organic solvents and strong acids. Application: For PerkinElmer ICP-MS. Gemtip Clear Sapphire Sample Tip, Gemtip Red Ruby Argon Tip, Optimized for ICP-MS (0.009 & 0.013 in orifices), Specially…
-
Spray chamber assembly, Mark 7, complete, for flame AA, for aqueous/acidic…
Agilent TechnologiesSpray chamber assembly, Mark 7, complete, for flame AA, for aqueous/acidic samples. Includes mixing paddle, fluorinated, p/n 110637000, spray chamber body, fluorinated, p/n 6210092090, pressure relief bung, fluorinated, p/n 1610118800, nebulizer block, p/n 9910093100, integrated nebulizer…
-
Viton Torch O-Ring Kit for NexION 2000/1000
PerkinElmerThis kit includes: 2.8 mm I.D. O-Rings, 4 Qty. 14 mm I.D. O-Ring, 1 Qty. 16 mm I.D. O-Ring, 1 Qty.
-
Quartz connector tube straight, ICP-MS
Agilent TechnologiesAgilent Technologies products are intended for sale/shipment within the US only. International customers should contact their local Agilent Technologies distributor to place orders for Agilent Technologies products.
-
7500 HMI Kit Supplies
Agilent TechnologiesICP-MS parts and supplies are designed, manufactured, and tested to the most rigorous specifications for your 7500 ICP-MS systems. Agilent Technologies products are intended for sale/shipment within the US only. International customers should contact their local Agilent Technologies…
-
Cyclonic spray chamber drain fitting
PerkinElmerCyclonic spray chamber drain fitting with ETFE capillary tubing - 24 length by 0.030 ID x 0.062 OD.
-
Capillary Tubing 18 0.043 x 0.017 for Mira Mist
PerkinElmer0. 5 meters of . 044 OD X . 018 ID. Clear Polyethylene Tubing with attached BRC 3 fitting for sample lines.
-
Spray Chamber
Agilent TechnologiesAgilent glass cyclonic, inert PFA spray chambers and supplies are equivalent to the PerkinElmer ICP-MS versions. These parts provide the best precision, efficient drainage, and reduced interferences and you can use them with complete confidence. Use the single pass glass cyclonic spray chamber for…
-
Eluo Nebulizer Cleaner
PerkinElmerEluo Nebulizer Cleaner Particle build-up in a nebulizer capillary and tip causes sample flow to be constricted, thereby reducing nebulizer efficiency andperformance. Previously there was no simple way to effectively clean and unblock nebulizers. Now, blocked nebulizers can be safelyand easily…
-
The D-Torch is a revolutionary new demountable torch design with interchangeable outer Tubes. Quartz outer Tubes are ideal for most aqueous samples, while ceramic outer Tubes last longer for samples with high dissolving solids or for organic applications, such as wear metals in engine oils.
-
The SII cyclonic Scott dual spray chamber, made of quartz, is designed to homogenize sample aerosol prior to introduction to the ICP-MS instrument. It features a secure, leak-free threaded drain port, o-ring-free connections to the nebulizer and torch injector, internal baffle, and threaded…
-
The D-Torch is a revolutionary new demountable torch design with interchangeable outer Tubes. Quartz outer Tubes are ideal for most aqueous samples, while ceramic outer Tubes last longer for samples with high dissolving solids or for organic applications, such as wear metals in engine oils.
-
3-Slot Quartz Torch for Optima 4300/5300/7300 V
PerkinElmerDemountable design using one-piece quartz tubing for plasma and auxiliary gas flow. Available in a wide range of styles from 0-slot to 3-slot torches, depending on instrument and application needs. Torches without slots are recommended for organic solvents. 1-slot torches are the standard torch for…
-
The baffled, cyclonic Twister spray chamber has a central transfer tube, which acts as a secondary particle separator, helping separate larger aerosol particles from the sample. This reduces solvent load in the plasma without compromising detection limits. The position of the baffle is carefully…
-
Nebulizer liquid fitting with ETFE capillary tubing - 4 length by 0. 020 ID x 0. 062 OD flanged onto female CTFE fitting Includes one male barb CTFE fitting.
-
Concentric Plus Nebulizers provide low dead volume and high sensitivity with excellent detection limits and washout. Each Plus nebulizer includes the FitKit+ gas and sample quick connect fittings. The connections are made with highpurity PFA, minimizing the chance of contamination during backflow…
-
This metal ball joint clip with tension screw is used to connect the spray chamber and torch in Optima 4300 V, 5300 V, and 7300 V ICP-OES series instruments.
-
Demountable design using one-piece quartz tubing for plasma and auxiliary gas flow. The torch operates at 25% reduced argon gas flows compared to the standard demountable quartz torch (N8122006).
-
The Axial View Purge Extension Window is a replaceable quartz window that slides into the purge extension between the torch and the optics. The Radial View Purge Extension Window Tube is a replaceable quartz Tube that slides into the mount between the torch and the optics for the radial view.
-
Cassette Torch Mount
Agilent TechnologiesAgilent torches and accessories are fully compatible with your PerkinElmer ICP-MS. The high efficiency demountable quartz torch operates at 25% reduced argon gas flow compared to the demountable quartz torch. The standard Agilent guarantee applies to our chemistries and supplies for PerkinElmer…
-
Cross-Flow II Replacement GemTip for ICP-MS
PerkinElmerIncludes a color coded set of ruby and sapphire GemTips optimized for use with ICP-MS. Orifice size: argon, (0.23mm, 0.009in) ruby red; sample, (0.34mm, 0.013in) clear. For use with the Cross-Flow II Nebulizer only.
-
This module kit includes: External Spray Chamber, Qty. 1 (N0791499) Inner Chamber for External Ryton/Type II Spray Chamber, Qty. 1 (N0582258) 2 mm I.D. Alumina Injector, Qty. 1 (N0791183) 1-Slot Quartz Torch, Qty. 1 (N0790131) End Cap Assembly for GemTip Cross-Flow Nebulizer, Qty. 1 (N0780546)…
-
The PC 3 is a small, robust Peltier cooled cyclonic spray chamber. The PC 3 offers the advantages of low memory effects, constant temperature, fast rinse-out, and high sample transport efficiency. The cooled outer walls of the PC 3 spray chamber enhance long-term signal stability, reduce…
-
ST3 MicroFlow PFA nebulizer
PerkinElmerThe ST3 MicroFlow PFA nebulizer has an exchangeable external sample uptake capillary. The sample uptake rate is controlled by the diameter of the external capillary or probe.
-
The Axial View Purge Extension Window is a replaceable quartz window that slides into the purge extension between the torch and the optics. The Radial View Purge Extension Window Tube is a replaceable quartz Tube that slides into the mount between the torch and the optics for the radial view.
-
-
The D-Torch is a revolutionary new demountable torch design with interchangeable outer Tubes. Quartz outer Tubes are ideal for most aqueous samples, while ceramic outer Tubes last longer for samples with high dissolving solids or for organic applications, such as wear metals in engine oils.
-
Ryton Scott Spray Chamber for Avio 200/500
PerkinElmerThe spray chamber is an integral part of the sample introduction system responsible for filtering the sample mist to permit the appropriate droplet size distribution to reach the plasma. It is corrosion resistant and is inert to most mineral acids, including hydrofluoric acid, aqua regia, and all…
-
F0 Encapsulated Micro Capillary
PerkinElmerF0 Encapsulated micro tubing for microflow rates with the lowest internal volume of any nebulizer. Includes 0. 25 mm i. d. (green marker) 70 cm long micro capillary. Compatible with all MEINHARD Plus nebulizers.
-
Nebulizer cleaner, for concentric neb.
Agilent TechnologiesAgilent Technologies products are intended for sale/shipment within the US only. International customers should contact their local Agilent Technologies distributor to place orders for Agilent Technologies products.
-
The MEINHARD concentric glass nebulizers reflect exacting standards in design and manufacturing. They provide excellent sensitivity and precision for aqueous solutions and samples with few dissolved solids (less than 1%). MEINHARD nebulizers for Optima instruments include Standard Nebulizer…
-
1-Slot Quartz Torch for Optima 8x00
PerkinElmerDemountable design using one-piece quartz tubing for plasma and auxiliary gas flow. Available in a wide range of styles from 0-slot to 3-slot torches, depending on instrument and application needs. Torches without slots are recommended for organic solvents. 1-slot torches are the standard torch for…