HPLC

Compare Tool

Select up to 3 products

1 - 32 of 363
Sort
View
Show
  • Solvent Inlet Filters

    Thermo Scientific

    For HPLC Systems Stainless steel 10µm inlet filters for longer lifetime No tools required for replacement Bottom-of-the-Bottle solvent filters: Efficient draw 100% PTFE polymer, including 2µm filter Built-in helium sparge port and frit

  • Deuterium Lamps

    Varsal

    2000+ hour long life Consistent intensity over time High signal stability

  • Upchurch PEEK Fingertight Fitting nut and ferrule 10-32

    MilliporeSigma

    Material: PEEK nut and ferrule Packaging: pkg of 10 ea I.D.:  0.0625 in. (1.5875 mm) Fitting:  nut and ferrule 10-32 General description The one-piece fitting, 55067-U, is convenient to use because the ferrule will not stick in a receiving port and can be easliy…

  • Opti-Cap GL-45 Bottle Tops

    Restek

    The most economical way to helium-sparge and deliver LC mobile phases. Opti-Cap tops fit all standard GL-45 bottles and have two 1/8" holes and one 1/16" hole for tubing. All three openings are designed for threaded PEEK plugs.

  • LC Stainless Steel Capillary Tubing

    Restek

    Whether you need to replace system tubing as part of your troubleshooting or want to reduce the dwell volume of your system as you move to narrower columns, Restek has the quality tubing in the lengths and IDs you need. Each ID is color coded, so it is easy to identify and replace correctly. Tubing…

  • Eco-Cap Bottle Top, ETFE

    Restek

    Fits all standard GL-45 bottles; has two 1/8-inch holes and one 1/16-inch hole for tubing. Holes are not threaded.

  • 1/4" HPLC Frits

    Restek

    We manufacture our frits from fine, chromatographic-grade 316 stainless steel, and we offer sizes to fit most column and pore sizes. To choose the correct frit, check its pore size compatibility with the particle size of the packing in the column. If the packing has a smaller particle size than the…

  • Seals And Pistons

    Agilent Technologies

    Pump seals should be replaced when there are leaks on the bottom of the pump head, when retention times are inconsistent, or when the pressure ripple is unstable. Each time the seals are replaced, the pistons (plungers) should be examined for scratches. Scratched pistons will cause small…

  • Universal Sealing Mats

    Restek

    Protect contents and prevent carryover with pre-slit cap mats Chemically resistant, silicone mats are excellent for compound storage to -80°C Pre-slit mats pierceable by autosampler needle, pipette tip, or probe Universal mat for sealing 0.45, 1.3, and 2.0 mL plates

  • Waste Overflow Indicator for LC Systems

    Restek

    The Restek waste overflow indicator will help keep your mobile phase waste where it belongs—in the waste container! Compact, battery-operated unit fits securely on solvent bottles and accommodates two waste streams. An audible alarm is given as the solvent waste container approaches capacity,…

  • Hub-Cap Adaptors

    Restek

    Allow the use of the Opti-Cap Top with 4-liter solvent bottles.

  • Fittings and Ferrules for 1/8" Tubing

    Restek

  • Solvent Inlet Filter for Agilent HPLC Systems

    Restek

  • Clean-Cut Tubing Cutter

    Restek

    Burr-free, perpendicular cuts that will not distort the tubing OD or close the ID Use on PEEK, PTFE, Tefzel, and other polymeric tubing

  • HPLC 30-Column Storage Cabinet

    Restek

    Tired of stacks of HPLC columns on your lab benches? This easy-to-install cabinet saves space and protects columns; the hinged door is clear to allow quick identification of column labels or tags. Saves space and protects columns* Hinged door is clear for quick identification of column…

  • Survival Kit for HPLC, PEEK

    Restek

    For start-up and maintenance in all HPLC systems. The PEEK Survival Kit is an invaluable parts kit that contains tubing, fittings, and tools essential for setting up and maintaining your HPLC system: PEEK tubing, connectors, and elbows, PTFE tubing, a tubing cutter and extra blades, a ValvTool…

  • Inert PEEK Tubing

    Restek

    Replaces stainless steel, titanium, PTFE, or Tefzel tubing Less oxygen permeable and more temperature resistant (to 100 °C) than PTFE or Tefzel tubing Use with PEEK finger-tight or flangeless fittings Use tubing ≤ 0.007" to 7,000 psi; tubing ≥ 0.010" ID to 5,000 psi

  • Peek Sample Loops

    Agilent Technologies

    Flexible PEEK loops have a clean, straight cut for low dead volume connections Inert to most organic solvents Wall thickness, temperature, exposure time and concentration of organic solvents affect the durability of PEEK tubing Concentrated nitric acid and sulfuric acid weaken PEEK…

  • Bluestem Glass Solvent Filter

    Restek

    Prevent the particulates and microbial growth in your LC solvents from entering your instrument with the new Restek Bluestem glass solvent filter. Restek Bluestem glass solvent filter provides clean mobile phase to extend the life of columns and pump seals 15 µm borosilicate glass…

  • 1100/1200 Needles and Needle Seats

    Agilent Technologies

    The needle should be replaced when it becomes bent, burred or blunt. The needle seat should be replaced when it is leaking or plugged. You should suspect a leak if you notice a trail of buffer crystals on the needle seat. The needle seat can become blocked if the sample contains particulates, as…

  • Rheodyne Series 7725i

    Agilent Technologies

    Stainless steel Most popular injection valve for analytical HPLC Loops range from 1 µl to 5 ml (20 µl loop installed) Built in position sensing switch provides the LC with reproducible start signal Selected as Agilent 1050 and 1100 manual injectors

  • EZwaste® Solvent Waste System

    Foxx Life Sciences

    EZ-Waste Solvent Waste System is designed to be an affordable solution for liquid waste disposal.Carbon exhaust filter traps solvent vapors,tube fittings secure waste tubes to carboy, providing the closes system necessary to prevent spills. 90° adapter included for maximum storage flexibility.…

  • Opti-Cap Adaptors

    Restek

    Allow the use of the Hub-Cap Top with GL-45 solvent bottles.

  • Xenon Lamps for Waters Detectors

    Restek

  • HPLC Detector Lamps

    Agilent Technologies

    Produced specifically to proprietary tolerances Reduced lamp-to-lamp variation Increased operating life Lamps for HPLC Detectors are produced using a new manufacturing process that results in more consistent operation characteristics. Lamps feature a more robust, more evenly…

  • Active Inlet Valve (AIV)

    Agilent Technologies

    The gold seal should be replaced after the valve has been removed a few times.

  • Stainless Steel Sample Loops

    Agilent Technologies

    Sample loops for Rheodyne 7725 Series and 7125 Series valves are not interchangeable due to the change in port angle Actual volumes can differ due to tolerance of metal tubing bore Accuracy of large metal loops is ±5%, intermediate loops ±10%, small loops ±30%

  • Solvent Filters for G1311/12/54A Pumps

    Agilent Technologies

    Unfiltered solvents or solvents contaminated with microbial growth can clog solvent inlet filters, reducing the lifetime of the filter and impacting pump performance. Remember to clean or replace the solvent inlet filters at least once every 3 months.

  • Capillary Stainless Steel Tubing Assemblies for Agilent HPLC Systems

    Restek

    Precut, micropolished tubing and preseated fittings for quick, easy maintenance of your Agilent HPLC systems Meet or exceed manufacturer's performance.

  • ULTRA-WARE® Flat Bottom HPLC Reservoirs without Graduations

    DWK Life Sciences (Kimble)

    Designed for preparation, storage and delivery of all liquid chromatography mobile phases.  As part of our ULTRA-WARE® series, these reservoirs are recommended for use under vacuum for filtration and vacuum degassing of mobile phase solvents. Plastic safety-coating blocks UV light…

  • Well Plates

    Restek

    ?Polypropylene plates with round-bottom wells reduce liquid retention; conical bottom provides optimal recovery of reagents. Nunc shared wall technology allows increased well volume for optimum storage capacity and improved mixing. Round well shape is ideal for applications that require…

  • Diode Array Detector (DAD)/Multiple Wavelength Detector (MWD)

    Agilent Technologies

    Agilent's certified lamps are manufactured under ISO 9001 certified environment and are fully traceable through out every step of the production process. Each lamp is then tested to ensure it meets Agilent's specifications for performance. Test equipment is regularly calibrated using…

Compare Tool

Select up to 3 products

Please Log In

Don't have an Account? Create one now.