Glass Joints

Compare Tool

Select up to 3 products

1 - 32 of 240
Sort
View
Show
  • Adapter has a 1/4 " -28 thread that accepts a female luer lock adapter which provides a convenient way to connect solid phase extraction (SPE) cartridges, tubes, or syringes with a male luer lock fitting to a standard male taper inner joint. The adapter provides for easier sample concentration…

  • Claisen style adapter with an additional standard taper outer joint at a 45° angle to the vertical outer joint.

  • Adapter has a tubulation at the top for use with a CG-1040 rubber fitting. Fitting permits insertion of plain stem thermometers or bleed tubes. Supplied complete with one CG-1040 rubber fitting.

  • Micro impinger designed for sampling of small volumes of air at low jet velocity, as per EPA Method 6. Impinger bottle is graduated from 5 to 30mL in 5mL subdivisions. Both the bottle and stopper have 24/40 standard taper joints. The nozzle being replaced with an extra coarse fritted gas dispersion…

  • Jacketed distilling column has indentations on the inner tube to support packing material. The jacket allows the column to be used as a condenser. Column has a top outer and lower inner standard taper joint. All sizes have an I.D. of approximately 10mm.

  • Vapor tube/bump trap adapter is designed to be used with the Büchi® R-200/205 rotary evaporators. This adapter combines a vapor tube adapter and a bump trap. Trap has an extra coarse fritted disc sealed between the lower inner joint and the top flange. Adapters have a 50mm OD top flange…

  • Reservoirs used for storing high performance, low pressure liquid chromatography mobile phase. Complete reservoir system includes a plastic coated graduated bottle, a standard cap assembly, and solvent and sparging filters. Cap assembly fits GL45 threaded bottles and has a PTFE bulkhead with three…

  • Similar to CG-1239, but with the condenser being a combination of a cold coil and Liebig. Water flows into hose connection “A” through the coil and exits the outer jacket through hose connection “B”. Head is excellent for use when distilling medium to high boiling point…

  • Similar to CG-1032, but with joints of non-similar sizes at the upper and lower portion of the adapter. Dimensions are the same as the CG-1032.

  • Similar to AF-0509 but having a top outer joint and lower inner joint of the same size. Addition of the outer joint permits use of the larger sizes of the CG-3022 septum stoppers for repeated needle penetrations. Adapter also allows for evacuation and transfer of product into another vessel with…

  • Similar to CG-1041, but with the addition of an Extra Coarse fritted disc between the lower inner and top outer joint.

  • Vigreux style column with indentations that run the entire length of the column for improved vapor-liquid contact. Column length refers to the effective length, measured from the lowest to highest indent in the column. Column has a top outer and lower inner standard taper joint.

  • Adapters for use with manifolds such as AF-0450 through AF-0454 to permit port connection to standard rubber hose. Adapters have hooks just below the grind for use with CG-110 stainless steel springs. The 24/40 size is available with a constriction above the serrated hose connection to permit bowl…

  • Used to monitor gas flow to reactions while providing a vent to the atmosphere. Reservoir head prevents oil from being sucked back into the system. Volume below the sidearm is approx 40mL. Bubbler has an 8mm OD top and side tubulations.

  • Adapters for use with AF-0060 thru AF-0062 vacuum manifolds that permit the manifold to be utilized with a multitude of standard glassware or tubing products. The AF-0070 adapters are to be used with either a Cajon® fitting on the main ports or at the ends of the manifold with heavy wall rubber…

  • Similar to CG-1241 but with the Vigreux column vacuum jacketed to improve distillation performance.

  • With standard taper outer joint at the top, and inner joints on the bottom and sidearm, all being the same size. Inner joints are at a 75º angle to one another.

  • Adapter used for reduced pressure filtration with plain stem buchner funnels. Top is flared to accept the listed size pluro stopper. The hose connection has an O.D. of 10mm at the largest serration. ADAPTER IS NOT SUPPLIED WITH RUBBER PLURO STOPPER, See CG-1401.

  • The 135° angle between the center line of the condenser and the receiver tubes allows the distillate to fall directly into the receiver tubes. This receiver can be used with short path style distilling heads. Complete receiver is supplied with distribution adapter, three 12mL receiver tubes,…

  • Adapter has a luer outer on top and a lower standard taper inner joint.

  • Adapter used for reduced pressure filtration with plain stem buchner funnels. Top has a HEAVY DUTY tooled flare to accept the listed size pluro stopper. Hose connection is 10mm OD at the largest serration. ADAPTER IS NOT SUPPLIED WITH RUBBER PLURO STOPPER. CG-1052-A-14 Accepts up to…

  • Sampling adapter for use with a 24/40 outer joint on the reaction kettle lid. Adapter is supplied complete with a 90° bore valve enabling connection to a luer type syringe for product sampling. Adapter has three inlets for use with 1/8” OD PTFE tubing or optional 5mm OD silicone septa.…

  • Inner joint with a sealed on lower tube extending 6in below the grind.

  • Used to regulate the flow of gases or liquids into reaction systems. PTFE stopcock has a bore of 2mm. Hose connection has an O.D. of 8mm at the middle serration.

  • Vacuum Adapter has a ground glass standard taper outer joint on top that provides a convenient leak free way to connect to the OP-6602, OP-6603 and OP-6604 disposable long stem filter funnels and a taper inner joint or a vial. The unique design of the long stem filter funnel and vacuum adapter…

  • Single stage oil diffusion pump useful with manifolds such as AF-0450 through AF-0454. Will provide vacuum of 10 -5 torr, at a pumping rate of approx 8L/sec. Instead of the typical internal heating coil, boiler has a round bottom for use with CG-10000-02 or CG-12000-02 100mL heating mantle. Use of…

  • Compact and simple distilling/splitter adapter for use with Chemglass process reactors. Vapor flows upward freely through the large vapors holes to the condenser. Distillate flow is directed using the valve to either the receiving flask or back to the reactor. Control valve is either a 0-4mm or a…

  • Allihn type filter tube with a 30mm O.D. disc. Height above the disc is 100mm, lower stem is 8mm O.D. x 55mm in length.

  • Adapter allows standard single neck round bottom flasks to be used as storage vessels. Sampling can be accomplished by removing 0-4mm Chem-Vac™ Chem-Cap® plug while maintaining inert gas purge thru sidearm. Available with a choice of 14/20 or 24/40 standard taper inner joint.

  • PTFE adapter for use with either 1/8"; or 1/4"; thermocouples. Adapter has an outer Viton® o-ring to form a grease-free, airtight seal between the adapter and the listed size of outer joint. The compression nut works in conjunction with the upper Viton® to provide a airtight seal…

  • This innovative and compact Dean-Stark receiver is designed for azeotropic distillations using solvents that are heavier than water. The solvent vapor travels through tube “A” to a condenser inserted in the top standard taper outer joint. Vapors are condensed and collected in the…

  • Distilling Adapter

    Chemglass

    Similar to CG-1235, but with the lower stopcock replaced with a 0-14mm treaded valve having Perfluoro o-rings and a 1/2” O.D. glass distillate takeoff for use with PFA compression tubing fittings. Adapter has two top outer joints and a lower inner. Style “B” with lower angled…

Compare Tool

Select up to 3 products