Extraction

Compare Tool

Select up to 3 products

HomeAll Products

Extraction

1 - 32 of 90
Sort
View
Show

Attention Thomas Scientific Customers

Due to current pandemic, lead times for PPE items are longer than what is listed on our website. Please expect shipping delays of all PPE products during this time.

  • Whatman Glass Soxhlet Extraction Thimbles

    GE Healthcare

    603G borosilicate glass fiber thimble with inorganic binder Resistant to temperatures up to 500°C (932°F) Manufactured with walls as thin as 1–1.5 mm Resistant to temperatures up to 500°C (932°F)Manufactured with walls as thin as 1–1.5 mm603G borosilicate glass fiber thimble with inorganic…

  • Filtration Vacuum Pump Kit

    GSC International, Inc.

    This Filtration Kit allows rapid separation of mixtures via vacuum filtration. The stopper is cut to hold a Buchner funnel. The hand-operated vacuum pump simplifies vacuum filtration, eliminating the need for a water source or vacuum aspirator. It is more economical than an electric vacuum pump.…

  • Whatman Standard Cellulose Extraction Thimbles

    GE Healthcare

    603 Standard Cellulose Extraction Thimbles made from high-quality cellulose available in a range of sizes. 603 Standard Cellulose Extraction Thimbles made from high-quality cellulose available in a range of sizes. Thimbles are available in a range of sizes suitable for use in thimble holders and…

  • SER 148 Series Solvent Extractors

    VELP

    Solvent extraction system suitable for the separation of a substance or a group of elements from solid and semi-solid samples according to the Randall technique. Beats Ordinary Soxhlet Extractor Up to 5 times faster than traditional Soxhlet (hot solvent vs. cold solvent) Low…

  • Soxhlet Extraction Apparatus

    Wilmad-LabGlass - SP Scienceware

    Used for the continuous extraction of solids with a suitable solvent. Units are supplied complete with flat bottom boiling flask, Soxhlet extractor and Allihn condenser. The extractor capacity shown is the solvent volume held in the extractor to the top of the siphon tube. The siphon tube is…

  • Whatman High-Purity Glass Soxhlet Extraction Thimbles

    GE Healthcare

    GE’s Whatman 100% borosilicate glass microfiber (HP-GF) thimbles are designed to fit most Soxhlet extraction units. They are well-suited to pollution monitoring when analysis of hot and acidic gases is required. Resistant to temperatures up to 500°C Binder-free, no chemical additives Designed…

  • Standard Cellulose Extraction Thimbles

    GE Healthcare

    Thimbles of type 603 are made from high-quality cellulose and 603 g thimbles are made from borosilicate glass fibers with an inorganic binder. For all automated extraction apparatus in common use, Whatman offers thimbles whose dimensions are matched exactly to those of the thimble holders to ensure…

  • Modified Soxhlet Extraction Apparatus

    Wilmad-LabGlass - SP Scienceware

    These large capacity Soxhlet extraction apparatus with modified design feature a wide mouth opening that provides easier charging and sample removal and a large area at the filter plate for rapid drainage of the solvent. Bulky solids may be placed directly on a fiberglass mat (not supplied) and…

  • Cellulose Extraction Thimble Filters

    Advantec MFS

    High purity, seamless thimble filters offered in 5 materials. Applications include analysis of fats, oils, grease, pesticides, pollutants, organics and addititives in plastics and rubbers. Cellulose Fiber is made from alpha cotton cellulose. These thimbles are binder-free and suitable for…

  • Micro Sublimer

    Chemglass

    Micro scale sublimer can be used with quantities as small as 0.5 grams. The sublimer has a capacity of 3mL between the lower portion of the cold finger and the interior bottom of the flask. With 24/25 standard taper joints to connect the flask and cold finger condenser.

  • PYREX Soxhlet Extractors

    Corning

    Includes an efficient Friedrichs condenser An efficient extraction apparatus for general purpose use Consists of an extractor, a special Friedrichs condenser and a flask, all equipped with Standard Taper joints Condenser tubulation o.d. is 10 mm for 3/8 inch i.d. tubing

  • Standard Glass Microfiber Extraction Thimbles

    GE Healthcare

    603G Glass fiber thimble with inorganic binder Designed to fit most commercially available Soxhlet extractors No binders are added Available in a range of sizes and wall thicknesses to suit your application Thimbles of type 603G are made from borosilicate glass fibers with…

  • PYREX® Fritted Glass Support Base, 47 mm, for Assembly of Graduated Funnel

    Corning

    This 47 mm fritted glass support base is designed for assembly with either the 300 mL graduated glass funnel, Cat. No. 33971-300 or 1000 mL graduated glass funnel, Cat. No. 33971-1L.

  • High-Purity Glass Extraction Thimbles

    GE Healthcare

    High-purity glass microfiber thimbles manufactured from 100% pure borosilicate glass are available for specialized applications. The thimbles are completely free of binders or additives and can be used at temperatures up to 500°C or when using solvents incompatible with cellulose thimbles.…

  • Extraction System

    Avantor - J.T.Baker®

    The BAKER SPE-12G is compatible with a large variety of glassware, including standard test tubes, volumetric flasks and autosampler vials. Samples are aspirated through disposable, prepacked extraction columns which selectively remove compounds from solution. Extracted compounds are then eluted…

  • Extraction Apparatus, Soxhlet

    Chemglass

    Similar to CG-1368, but supplied with a round bottom instead of a flat bottom flask. All specifications are the same as CG-1368.

  • Borosil® Complete Soxhlet Extraction Apparatus

    Borosil

    Ideal for laboratory-scale refluxing, botanical extraction, and cannabis extraction applications, Borosil® Soxhlet Extractors are constructed from stress-free, 3.3 Low-Expansion Borosilicate that is mechanically strong and incredibly resistant to thermal shock. Borosil® Soxhlet…

  • Extraction Apparatus, Soxhlet

    Chemglass

    Soxhlet type extraction apparatus used for continuous extraction of solids with a suitable solvent. Extractor uses paper or CG-1372 glass thimbles. Condenser has an enlarged uptake tube to improve condensing capacity. Complete apparatus consists of an Allihn condenser, extractor and flat bottom flask.

  • Whatman Quartz Fiber Extraction Thimbles

    GE Healthcare

    High-purity Whatman quartz thimbles from GE support accurate, reproducible emission testing by providing low extractable levels and temperature resistance up to 800°C. Appropriate for manual sampling in aggressive environments Suitable for both solvent extraction and air sampling applications …

  • PYREX® Graduated Funnel, 47 mm, for Assembly with Fritted Glass Support Base

    Corning

    These graduated funnels,are designed for assembly with the fritted glass support base. Cat. No. 33972-B.

  • Goldfisch Fat Extractor Accessories & Replacement Parts

    Labconco

    Goldfisch Fat Extractor Accessories and Replacement Parts include glassware, gaskets and other components.

  • Xenosep® SPE Starter Kit

    Hach

    At last, an easy, EPA-approved method for oil and grease! Xenosep Solid-Phase Extraction (SPE) Systems offer the easiest and most cost effective way to test for Oil and Grease using EPA Method 1664A. Fast, in-house results enable you to maintain control over your plant discharges in real time…

  • Extra Large Soxhlet Extraction Apparatus

    Wilmad-LabGlass - SP Scienceware

    This borosilicate glass X-Large Soxhlet extraction apparatus is used for the continuous extraction of solids with a suitable solvent. Complete units are supplied with a round bottom boiling flask (LG-7220-184 or LG-7220-188), a Soxhlet extraction tube (70mm or 100mm approx. I.D.) and an Allihn…

  • Soxhlet/Dean Stark Extraction Apparatus

    DWK Life Sciences (Kimble)

    This apparatus combines two analytical techniques, Soxhlet extraction and Dean-Stark azeotropic distillation, into a single process for the removal of water, chlorinated dibenzo-p-dioxins (CCDs) and chlorinated dibenzofurans (CDFs) from wet particulate samples. Determination of water and…

  • PTFE Extraction Thimble Filters

    Advantec MFS

    High purity, seamless thimble filters offered in 5 materials. Applications include analysis of fats, oils, grease, pesticides, pollutants, organics and addititives in plastics and rubbers. Advantec offers thimble filters in pure PTFE Fiber and PTFE/Silica Fiber. PTFE is inherently hydrophobic…

  • PYREX® Extractors With Standard Taper Joints

    Corning

    Condensers have water-jacketed Standard Taper inner joint. Complete with condenser, flask and extraction tube. The low thermal expansion rate means that the PYREX brand extractors can be routinely used in applications requiring protracted heating at temperatures as high as 230°C. The inherent…

  • Glass Extraction Thimble Filters

    Advantec MFS

    High purity, seamless thimble filters offered in 5 materials. Applications include analysis of fats, oils, grease, pesticides, pollutants, organics and addititives in plastics and rubbers. Glass Fiber thimbles are made of pure borosilicate glass microfibers. These binder-free filters can…

  • Soxhlet Extraction Apparatus Flasks

    DWK Life Sciences (Wheaton)

    Flat-bottom flask for Soxhlet Extraction Apparatus 1/Case

  • Extraction Apparatus, Soxhlet, with Friedrichs Condenser

    Ace Glass

    Improved design of ACE extractor with Friedrichs Condenser in place of Allihn Condenser. Complete consists of flask cap, condenser, extractor, and flask.

  • Extraction Apparatus Liquid-Liquid

    Ace Glass

    Designed for U.S.E.P.A. Priority Pollutant analysis using Method 625 (base neutrals/acid extractables). Accommodates 1L sample and approximately 200mL of a heavier-than-water extracting solvent. Features an extractor body designed to accept a common condenser with a 45/50 joint, a 24/40 opening…

  • Extraction Apparatus, Liquid-Liquid, Heavier- or Lighter-than-Water

    Ace Glass

    A liquid-liquid extractor for use with lighter or heavier-than-water extracting solvents. Overflow and boil-up tube uses Ace-Thred Connections, thus allowing easy removal for cleaning to reduce cross contamination among samples. Complete consists of:Extractor Body, (approx.1.3L capacity),…

  • QM-A Quartz Fiber Filters and Thimbles

    GE Healthcare

    Grade QM-A circles High-purity quartz (SiO2) microfiber filters are used for air sampling in acidic gases, stacks, flues and aerosols, particularly at high temperatures up to 500° C and in PM-10 testing. Because of the low level of alkaline earth metals, "artifact"…

Compare Tool

Select up to 3 products

Please Log In

Don't have a web profile? Create one now.