Extraction

Compare Tool

Select up to 3 products

HomeAll Products

Extraction

1 - 32 of 87
Sort
View
Show
  • 125 ml App, Soxhlet Extraction, Gnd

    DWK Life Sciences (Wheaton)

    Use this apparatus for continuous extraction of analytes from a solid into an organic solvent. As the flask containing the solvent is heated, vapors rise in the larger outside tube, enter the water-cooled condenser, and liquate. When the liquid level in the extractor reaches the top of the bent…

  • Cellulose Extraction Thimble Filters

    Advantec MFS

    High purity, seamless thimble filters offered in 5 materials. Applications include analysis of fats, oils, grease, pesticides, pollutants, organics and addititives in plastics and rubbers. Cellulose Fiber is made from alpha cotton cellulose. These thimbles are binder-free and suitable for…

  • Whatman Standard Cellulose Extraction Thimbles

    GE Healthcare

    603 Standard Cellulose Extraction Thimbles made from high-quality cellulose available in a range of sizes. 603 Standard Cellulose Extraction Thimbles made from high-quality cellulose available in a range of sizes. Thimbles are available in a range of sizes suitable for use in thimble holders and…

  • Micro Soxhlet Extraction Apparatus

    DWK Life Sciences (Wheaton)

    Used for continuous extraction of analytes from a solid into an organic solvent WHEATON Connection eliminates the need for hooks, springs and clamps common to standard ground joint designs As the flask containing the solvent is heated, vapors rise in the larger outside tube, enter the…

  • SER 148 Series Solvent Extractors

    VELP

    Solvent extraction system suitable for the separation of a substance or a group of elements from solid and semi-solid samples according to the Randall technique. Beats Ordinary Soxhlet Extractor Up to 5 times faster than traditional Soxhlet (hot solvent vs. cold solvent) Low…

  • High-Purity Glass Extraction Thimbles

    GE Healthcare

    High-purity glass microfiber thimbles manufactured from 100% pure borosilicate glass are available for specialized applications. The thimbles are completely free of binders or additives and can be used at temperatures up to 500°C or when using solvents incompatible with cellulose thimbles.…

  • Extraction Apparatus, Soxhlet, with Friedrichs Condenser

    Ace Glass

    Improved design of ACE extractor with Friedrichs Condenser in place of Allihn Condenser. Complete consists of flask cap, condenser, extractor, and flask.

  • PVC Extraction Manifold

    Advantec MFS

    Tapered branch accepts 40/35 female joint Broad base for extra stability Ideal for EPA Method 1664 oil and grease analysis Lightweight and durable PVC material makes this extraction manifold a great alternative to stainless steel. Polyvinylchloride(PVC) is resistant to acids. The…

  • Extraction Thimbles, Glass

    Ace Glass

    With an ACE fritted disc sealed in. Can be used in any standard Soxhlet extraction apparatus. The sizes below correspond to the size specifications of extraction bodies and will fit those units. Available in porosities A, B, C, D and E. All porosities of a given size are priced the same. Height…

  • Extra Large Soxhlet Extraction Apparatus

    Wilmad-LabGlass - SP Scienceware

    This borosilicate glass X-Large Soxhlet extraction apparatus is used for the continuous extraction of solids with a suitable solvent. Complete units are supplied with a round bottom boiling flask (LG-7220-184 or LG-7220-188), a Soxhlet extraction tube (70mm or 100mm approx. I.D.) and an Allihn…

  • Standard Glass Microfiber Extraction Thimbles

    GE Healthcare

    603G Glass fiber thimble with inorganic binder Designed to fit most commercially available Soxhlet extractors No binders are added Available in a range of sizes and wall thicknesses to suit your application Thimbles of type 603G are made from borosilicate glass fibers with…

  • Modified Soxhlet Extraction Apparatus

    Wilmad-LabGlass - SP Scienceware

    These large capacity Soxhlet extraction apparatus with modified design feature a wide mouth opening that provides easier charging and sample removal and a large area at the filter plate for rapid drainage of the solvent. Bulky solids may be placed directly on a fiberglass mat (not supplied) and…

  • Soxhlet Extraction Apparatus Flasks

    DWK Life Sciences (Wheaton)

    Flat-bottom flask for Soxhlet Extraction Apparatus 1/Case

  • PYREX® 500mL Kuderna-Danish Concentrator Apparatus without Hooks

    Corning

    These 500mL PYREX® Kuderna Danish Concentrators are supplied with Keck clamps instead of spring hooks. The complete apparatus consists of a 3-Ball Snyder column (with 24/40 Standard Taper joints), a 500mL flask (with 24/40 Standard Taper top and 19/22 Standard Taper lower joint), and a…

  • Glass Extraction Thimbles

    Chemglass

    All glass extraction thimble permits viewing during extraction process and subsequent weighing. Sizes correspond to CG-1368 or CG-1369 extractor. Available in coarse or extra coarse porosity.

  • Soxhlet/Dean Stark Extraction Apparatus

    DWK Life Sciences (Kimble)

    This apparatus combines two analytical techniques, Soxhlet extraction and Dean-Stark azeotropic distillation, into a single process for the removal of water, chlorinated dibenzo-p-dioxins (CCDs) and chlorinated dibenzofurans (CDFs) from wet particulate samples. Determination of water and…

  • Extraction Apparatus, Soxhlet

    Chemglass

    Similar to CG-1368, but supplied with a round bottom instead of a flat bottom flask. All specifications are the same as CG-1368.

  • Goldfisch Fat Extractor Accessories & Replacement Parts

    Labconco

    Goldfisch Fat Extractor Accessories and Replacement Parts include glassware, gaskets and other components.

  • Whatman High-Purity Glass Soxhlet Extraction Thimbles

    GE Healthcare

    GE’s Whatman 100% borosilicate glass microfiber (HP-GF) thimbles are designed to fit most Soxhlet extraction units. They are well-suited to pollution monitoring when analysis of hot and acidic gases is required. Resistant to temperatures up to 500°C Binder-free, no chemical additives Designed…

  • Micro-Glass Fiber Thimbles, ET/MG160

    Ahlstrom

    Glass thimbles are used to sample dust particles and aerosols from gaseous streams in the analytical registration of environmental pollution and for Soxhlet extractions requiring solvents too aggressive for the cellulose thimbles.

  • Standard Cellulose Extraction Thimbles

    GE Healthcare

    Thimbles of type 603 are made from high-quality cellulose and 603 g thimbles are made from borosilicate glass fibers with an inorganic binder. For all automated extraction apparatus in common use, Whatman offers thimbles whose dimensions are matched exactly to those of the thimble holders to ensure…

  • SYNTHWARE Soxlet Extractors

    Kemtech America

    Soxlet Extractor Upper Joint: Available in 34/45, 45/50, and 55/50 Lower Joint: Available 24/40 Used for the extraction of solids with a solvent.

  • Whatman Quartz Fiber Extraction Thimbles

    GE Healthcare

    High-purity Whatman quartz thimbles from GE support accurate, reproducible emission testing by providing low extractable levels and temperature resistance up to 800°C. Appropriate for manual sampling in aggressive environments Suitable for both solvent extraction and air sampling applications …

  • Fat Extraction Flask, AOAC

    Wilmad-LabGlass - SP Scienceware

    These borosilicate glass extraction apparatus are used to measure the fat content in dairy and other food products. Reference AOAC 989.05 for fat in milk. Top is tooled to accept rubber stoppers (not included).

  • Soxhlet Extraction Body

    DWK Life Sciences (Kimble)

    Extractor body only, used as component part of 585050 Soxhlet extraction assemblies. Manufactured from 33 expansion, low extractable borosilicate glass conforming to USP Type I and ASTM E438, Type I, Class A requirements

  • Whatman High Performance Cellulose Extraction Thimbles

    GE Healthcare

    GE’s Whatman cellulose thimbles are manufactured from high-quality alpha cellulose cotton linter for high-performance use in automated Soxhlet extractor systems. Used in air and waste gas analysis. Used in a wide variety of solid-liquid extraction studies, including lipid and…

  • Xenosep® SPE Starter Kit

    Hach

    At last, an easy, EPA-approved method for oil and grease! Xenosep Solid-Phase Extraction (SPE) Systems offer the easiest and most cost effective way to test for Oil and Grease using EPA Method 1664A. Fast, in-house results enable you to maintain control over your plant discharges in real time…

  • Jumbo Extraction Apparatus

    Chemglass

    Jumbo Soxhlet extraction apparatus equipped with a Duran flange at the top of the extractor. Flange is formed with a groove in the flat portion of the mating surface to accept a PTFE covered silicone o-ring to permit grease free assembly. The adapter between the condenser and extractor has a top…

  • Extractor, Liquid-Liquid, with Stopcock

    Chemglass

    Similar in design to CG-1360 but with the addition of a 2mm PTFE stopcock in the return tube. Stopcock stops the flow after the extraction is complete. For samples of 1 liter plus approximately 200mL of extracting solvent. Extractor has a 45/50 top outer joint and a 24/40 inner joint on the uptake…

  • Micro Sublimer

    Chemglass

    Micro scale sublimer can be used with quantities as small as 0.5 grams. The sublimer has a capacity of 3mL between the lower portion of the cold finger and the interior bottom of the flask. With 24/25 standard taper joints to connect the flask and cold finger condenser.

  • Whatman Glass Soxhlet Extraction Thimbles

    GE Healthcare

    603G borosilicate glass fiber thimble with inorganic binder Resistant to temperatures up to 500°C (932°F) Manufactured with walls as thin as 1–1.5 mm Resistant to temperatures up to 500°C (932°F)Manufactured with walls as thin as 1–1.5 mm603G borosilicate glass fiber thimble with inorganic…

  • Extraction Apparatus, Liquid-Liquid, Heavier- or Lighter-than-Water

    Ace Glass

    A liquid-liquid extractor for use with lighter or heavier-than-water extracting solvents. Overflow and boil-up tube uses Ace-Thred Connections, thus allowing easy removal for cleaning to reduce cross contamination among samples. Complete consists of:Extractor Body, (approx.1.3L capacity),…

Compare Tool

Select up to 3 products

Please Log In

Don't have an Account? Create one now.