Extraction

Compare Tool

Select up to 3 products

HomeAll Products

Extraction

1 - 32 of 88
Sort
View
Show
  • KIMAX SOXHLET TYPE EXTRACTORS

    DWK Life Sciences (Kimble)

    With Standard Taper Joints Complete with Allihn condenser with joint at bottom, Soxhlet extraction tube with top and bottom joint and flat-bottom flask Available in small, medium and large capacities Small Extractor with 125 mL flask (4406E10, E16, E22) Extraction chamber 30 mm i.d. x 95…

  • Whatman Standard Cellulose Extraction Thimbles

    GE Healthcare

    603 Standard Cellulose Extraction Thimbles made from high-quality cellulose available in a range of sizes. 603 Standard Cellulose Extraction Thimbles made from high-quality cellulose available in a range of sizes. Thimbles are available in a range of sizes suitable for use in thimble holders and…

  • Norton Alundum Extraction Thimbles

    Saint Gobain

    For the extraction of soaps, fats, foods, rubber, etc. by both organic and inorganic solvents These thimbles offer the advantages of being rapid, durable and readily cleaned by ignition 4395L15 thimble is used in asphalt extraction apparatus for ASTM Standard D 367; AASHTO T-81; and Barrett tests…

  • Micro Soxhlet Extraction Apparatus

    DWK Life Sciences (Wheaton)

    Used for continuous extraction of analytes from a solid into an organic solvent WHEATON Connection eliminates the need for hooks, springs and clamps common to standard ground joint designs As the flask containing the solvent is heated, vapors rise in the larger outside tube, enter the…

  • Standard Cellulose Extraction Thimbles

    GE Healthcare

    Thimbles of type 603 are made from high-quality cellulose and 603 g thimbles are made from borosilicate glass fibers with an inorganic binder. For all automated extraction apparatus in common use, Whatman offers thimbles whose dimensions are matched exactly to those of the thimble holders to ensure…

  • PYREX Soxhlet Extractors

    Corning

    Includes an efficient Friedrichs condenser An efficient extraction apparatus for general purpose use Consists of an extractor, a special Friedrichs condenser and a flask, all equipped with Standard Taper joints Condenser tubulation o.d. is 10 mm for 3/8 inch i.d. tubing

  • Cellulose Extraction Thimbles

    Ahlstrom

    Ahlstrom‘s high purity cellulose extraction thimbles are most commonly used in Soxhlet extraction units for the separation of individual components from a mixture of solids and semisolids by solvent extraction. The use of a Soxhlet extractor provides a safe method of extraction with toxic or…

  • Soxhlet Extraction Apparatus

    Wilmad-LabGlass - SP Scienceware

    Used for the continuous extraction of solids with a suitable solvent. Units are supplied complete with flat bottom boiling flask, Soxhlet extractor and Allihn condenser. The extractor capacity shown is the solvent volume held in the extractor to the top of the siphon tube. The siphon tube is…

  • PYREX® Fritted Glass Support Base, 47 mm, for Assembly of Graduated Funnel

    Corning

    This 47 mm fritted glass support base is designed for assembly with either the 300 mL graduated glass funnel, Cat. No. 33971-300 or 1000 mL graduated glass funnel, Cat. No. 33971-1L.

  • Quartz Extraction Thimble Filters

    Advantec MFS

    High purity, seamless thimble filters offered in 5 materials. Applications include analysis of fats, oils, grease, pesticides, pollutants, organics and addititives in plastics and rubbers. Silica Fiber (Quartz) thimbles are made of pure quartz microfibers and are binder-free. Ideal for air…

  • Sediment Extraction Apparatus

    Koehler

    Test Method Determines sediment content of crude oil and fuel oils by extraction with toluene. A test portion of the sample is placed in a refractory thimble. Toluene is gently boiled and its vapors condensed and allowed to drip into the sample funnel. The toluene washes out all of the…

  • PTFE Extraction Thimble Filters

    Advantec MFS

    High purity, seamless thimble filters offered in 5 materials. Applications include analysis of fats, oils, grease, pesticides, pollutants, organics and addititives in plastics and rubbers. Advantec offers thimble filters in pure PTFE Fiber and PTFE/Silica Fiber. PTFE is inherently hydrophobic…

  • Extractor, Liquid-Liquid, with Stopcock

    Chemglass

    Similar in design to CG-1360 but with the addition of a 2mm PTFE stopcock in the return tube. Stopcock stops the flow after the extraction is complete. For samples of 1 liter plus approximately 200mL of extracting solvent. Extractor has a 45/50 top outer joint and a 24/40 inner joint on the uptake…

  • QM-A Quartz Fiber Filters and Thimbles

    GE Healthcare

    Grade QM-A circles High-purity quartz (SiO2) microfiber filters are used for air sampling in acidic gases, stacks, flues and aerosols, particularly at high temperatures up to 500° C and in PM-10 testing. Because of the low level of alkaline earth metals, "artifact"…

  • Extraction Apparatus, Soxhlet, Micro

    Chemglass

    Micro size Soxhlet extractor for use with 10 x 50mm paper or glass thimbles. Extractor body has a 19/22 top inner joint and a 14/20 lower inner joint. Complete apparatus consists of the extractor body, condenser, and 25mL round bottom flask. Glass thimbles must be ordered separately.

  • Whatman Glass Soxhlet Extraction Thimbles

    GE Healthcare

    603G borosilicate glass fiber thimble with inorganic binder Resistant to temperatures up to 500°C (932°F) Manufactured with walls as thin as 1–1.5 mm Resistant to temperatures up to 500°C (932°F)Manufactured with walls as thin as 1–1.5 mm603G borosilicate glass fiber thimble with inorganic…

  • Whatman High Performance Cellulose Extraction Thimbles

    GE Healthcare

    GE’s Whatman cellulose thimbles are manufactured from high-quality alpha cellulose cotton linter for high-performance use in automated Soxhlet extractor systems. Used in air and waste gas analysis. Used in a wide variety of solid-liquid extraction studies, including lipid and…

  • PYREX® Extra Coarse Porosity Fritted Thimbles

    Corning

    These PYREX® extra coarse porosity fritted thimbles are designed for use in PYREX® Soxhlet extractors when it is desirable to weigh the material extracted or where paper thimbles may be attacked by the chemicals used. For PYREX® extractors and extraction apparatus, see Nos. 3740 through 3880. .

  • Constant Temperature Air Cabinet

    Koehler

    Provides a constant temperature environment and regulated air pressure per ASTM specifications. Consists of an insulated airtight cabinet with pressure system to accommodate four pressure bleeding test cells. Equipped with electric heater, solid state controller, cooling coil and circulating fan…

  • Extraction Apparatus Liquid-Liquid

    Ace Glass

    Designed for U.S.E.P.A. Priority Pollutant analysis using Method 625 (base neutrals/acid extractables). Accommodates 1L sample and approximately 200mL of a heavier-than-water extracting solvent. Features an extractor body designed to accept a common condenser with a 45/50 joint, a 24/40 opening…

  • Fat Extraction Flask, AOAC

    Wilmad-LabGlass - SP Scienceware

    These borosilicate glass extraction apparatus are used to measure the fat content in dairy and other food products. Reference AOAC 989.05 for fat in milk. Top is tooled to accept rubber stoppers (not included).

  • Sublimation Apparatus, 150mL

    Chemglass

    Two-piece grease-free sublimer with a flat bottom to enable heating on a hot plate stirrer. Condenser has a large top opening for use with dry ice / acetone or liquid nitrogen. Connection between the flask and condenser is made with a flat o-ring joint permitting parts to be gently separated for…

  • Extraction Apparatus, Soxhlet, with Friedrichs Condenser

    Ace Glass

    Improved design of ACE extractor with Friedrichs Condenser in place of Allihn Condenser. Complete consists of flask cap, condenser, extractor, and flask.

  • High-Purity Glass Extraction Thimbles

    GE Healthcare

    High-purity glass microfiber thimbles manufactured from 100% pure borosilicate glass are available for specialized applications. The thimbles are completely free of binders or additives and can be used at temperatures up to 500°C or when using solvents incompatible with cellulose thimbles.…

  • Jumbo Extraction Apparatus

    Chemglass

    Jumbo Soxhlet extraction apparatus equipped with a Duran flange at the top of the extractor. Flange is formed with a groove in the flat portion of the mating surface to accept a PTFE covered silicone o-ring to permit grease free assembly. The adapter between the condenser and extractor has a top…

  • Vacuum Manifold Accessories

    Agilent Technologies

  • Borosil® Complete Soxhlet Extraction Apparatus

    Borosil

    Ideal for laboratory-scale refluxing, botanical extraction, and cannabis extraction applications, Borosil® Soxhlet Extractors are constructed from stress-free, 3.3 Low-Expansion Borosilicate that is mechanically strong and incredibly resistant to thermal shock. Borosil® Soxhlet…

  • Whatman High-Purity Glass Soxhlet Extraction Thimbles

    GE Healthcare

    GE’s Whatman 100% borosilicate glass microfiber (HP-GF) thimbles are designed to fit most Soxhlet extraction units. They are well-suited to pollution monitoring when analysis of hot and acidic gases is required. Resistant to temperatures up to 500°C Binder-free, no chemical additives Designed…

  • Whatman Extraction Thimbles for DIONEX ASE

    GE Healthcare

    Extraction thimbles for DIONEX ASE 200 extraction cell Extraction thimbles for DIONEX ASE 200 extraction cell

  • PYREX Accelerated One-Step Extractor/Concentrator

    Corning

    Modular PYREX Accelerated One-Step extractor-concentrator performs extraction, concentration, and drying with the same apparatus and is designed for use with solvents of heavier specific gravity than sample being extracted.  Extraction and concentration can be done in 1/3 of the time.…

  • Gregar Extractor

    Chemglass

    The Gregar Extractor† is the first major advance in laboratory extractor design in over 100 years. Developed by Joseph Gregar and Ken Anderson of Argonne National Laboratories, this extractor is the only unit on the market that can perform all three common types of extraction. During solid…

  • Whatman Quartz Fiber Extraction Thimbles

    GE Healthcare

    High-purity Whatman quartz thimbles from GE support accurate, reproducible emission testing by providing low extractable levels and temperature resistance up to 800°C. Appropriate for manual sampling in aggressive environments Suitable for both solvent extraction and air sampling applications …

Compare Tool

Select up to 3 products

Please Log In

Don't have an Account? Create one now.