YMC Chromatography Columns

Compare Tool

Select up to 3 products

1 - 32 of 157
Sort
View
Show
  • ODS-AM is a high carbon load C18 packing that is similar in selectivity to ODS-A. The major difference between these bonded phases is that ODS-AM has extremely tight specification criteria which provides excellent peak shape and more reproducible separation. Application: For Alkaloids Long-term…

  • The high purity silica found in YMC-Pack Silica columns provides virtually complete sample recovery. The absence of silica impurities reduces non-specific sample adsorption which lowers sample recovery and may cause unusual peak shapes. The totally porous nature of the silica found in YMC-Pack…

  • ODS-A in 120Å pore size is the first choice of many chromatographers for high performance reversed phase separations. It has selectivity for the separation of a wide range of organic compounds found in pharmaceutical, chemical and biotechnology industries. ODS-A is a high coverage, fully endcapped…

  • In a reversed-phase mode, Cyano columns are the most polar and least retentive of all reversed-phase packings. Extremely hydrophobic compounds, which do not elute on standard C18 and C8 packings with typical reversed-phase eluents, can be chromatographed using Cyano columns. In addition, the unique…

  • Hydrosphere C18 is designed to maintain adequate hydrophilicity on the packing surface for superior separation of hydrophilic compounds. Hydrophilic compounds are retained with much greater affinity than with conventional ODS columns, permitting the product to be used with 100% water eluent, a…

  • The choice of columns for analysis of difficult compounds by HPLC YMC-Pack Pro C18 columns start with a tightly controlled, highly purified silica gel, followed by a high-coverage C18 bonding and finish with a unique endcapping procedure utilizing Lewis acid-Lewis base chemistry. 2 µm particle size…

  • A stainless steel tube with a screw and an endfitting are directly connected (screw type). Since YMC original empty columns use no ferrule, there is no danger of endfitting dislocation when the column is packed and used under high pressure.

  • ODS-A in 120Å pore size is the first choice of many chromatographers for high performance reversed phase separations. It has selectivity for the separation of a wide range of organic compounds found in pharmaceutical, chemical and biotechnology industries. ODS-A is a high coverage, fully endcapped…

  • All phases in the Pro-family are ideal for the analysis of all types of organic molecules but specifically basic and metal chelating compounds. The ultrapure silica and very low residual silanol activity means that these columns frequently do not require the use of ion-pairing reagents or…

  • YMC-Triart Diol-HILIC is a HILIC (hydrophilic interaction chromatography) column based on an organic/inorganic hybrid particle synthesized with dihydroxypropyl groups. Triart Diol-HILIC is ideal for a separation of polar and hydrophilic compounds that are not retained by reversed-phase (C18, C8,…

  • Pro C18 RS has excellent peak shape for the separation of basic compounds because of high quality end capping. Pro C18 RS has high recognition of stereoselectivity because of high carbon polymeric type bonding. Pro C18 RS can be used over a wide pH range (1-10) to aid in method development. High…

  • ODS-AM is a high carbon load C18 packing that is similar in selectivity to ODS-A. The major difference between these bonded phases is that ODS-AM has extremely tight specification criteria which provides excellent peak shape and more reproducible separation. Application: For Alkaloids Long-term…

  • YMCbasic is a unique reversed-phase column designed for analysis of pharmaceuticals and other basic compounds. YMCbasic utilizes a novel silica synthesis and state-of-art silane bonding to create a column which gives true reversed-phase character, high resolution and excellent peak shape for the…

  • The high purity silica found in YMC-Pack Silica columns provides virtually complete sample recovery. The absence of silica impurities reduces non-specific sample adsorption which lowers sample recovery and may cause unusual peak shapes. The totally porous nature of the silica found in YMC-Pack…

  • ODS-AQ is a unique reversed-phase material with both a hydrophobic high carbon loading and a relatively hydrophilic surface. Because of the hydrophilic surface, ODS-AQ can be "wetted" with polar eluents. ODS-AQ provides chromatographers reproducible retention and excellent peak shape in highly…

  • All phases in the Pro-family are ideal for the analysis of all types of organic molecules but specifically basic and metal chelating compounds. The ultrapure silica and very low residual silanol activity means that these columns frequently do not require the use of ion-pairing reagents or…

  • The high purity silica found in YMC-Pack Silica columns provides virtually complete sample recovery. The absence of silica impurities reduces non-specific sample adsorption which lowers sample recovery and may cause unusual peak shapes. The totally porous nature of the silica found in YMC-Pack…

  • YMC-Triart C18 is a hybrid silica-based ODS column emphasizing durability, low operating pressure, and excellent performance. YMC-Triart C18 has been developed and is manufactured using state-of-the-art technologies that define materials, granulation, and surface modification. Application: For…

  • YMC-Triart C8 is a versatile column with excellent chemical durability that is equivalent to YMC-Triart C18. YMC-Triart C8 is suitable for fast analysis of samples containing hydrophobic compounds that are strongly retained on C18 columns or samples containing compounds with large differences in…

  • Phenyl columns provide unique selectivity when compared to aliphatic straight chain reversed phases such as ODS, C8 and C4. The p electrons of the phenyl group can interact with the aromatic ring of an analyte to increase retention relative to non-aromatic species. Phenyl also has application as an…

  • YMC-Pack C4 (Butyl) columns are less hydrophobic than C8 or C18 packings, and generally utilize more aqueous eluents than either of these reversed phase column types. When compared to C8 and C18 columns using the same eluent, C4 columns show significantly shorter retention for non-polar compounds.…

  • In a reversed-phase mode, Cyano columns are the most polar and least retentive of all reversed-phase packings. Extremely hydrophobic compounds, which do not elute on standard C18 and C8 packings with typical reversed-phase eluents, can be chromatographed using Cyano columns. In addition, the unique…

  • In a reversed-phase mode, Cyano columns are the most polar and least retentive of all reversed-phase packings. Extremely hydrophobic compounds, which do not elute on standard C18 and C8 packings with typical reversed-phase eluents, can be chromatographed using Cyano columns. In addition, the unique…

  • The hydrophobicity of YMC-Pack C8 is moderate for a reversed-phase packing material. Retention times of samples on YMC-Pack C8 tend to be shorter than those on ODS stationary phase. The moderate hydrophobicity of YMC-Pack C8 makes it useful for separating samples with relatively high…

  • Meteoric Core products feature ultra fast separation and outstanding resolution, excellent peak shape on basic and coordination compounds, a wide usable pH range, and a low column bleed.

  • YMC-Triart C18 is a hybrid silica-based ODS column emphasizing durability, low operating pressure, and excellent performance. YMC-Triart C18 has been developed and is manufactured using state-of-the-art technologies that define materials, granulation, and surface modification. Long column…

  • Meteoric Core products feature ultra fast separation and outstanding resolution, excellent peak shape on basic and coordination compounds, a wide usable pH range, and a low column bleed.

  • YMC-Pack Diol-NP shows retention behavior of normal-phase chromatography when it is used with low-polarity mobile phases. Hydroxyl groups on the surface of the stationary phase act as polar groups. YMC-Pack Diol-NP is as widely applicable to normal-phase separation as silica gel. It is also useful…

  • Phenyl columns provide unique selectivity when compared to aliphatic straight chain reversed phases such as ODS, C8 and C4. The p electrons of the phenyl group can interact with the aromatic ring of an analyte to increase retention relative to non-aromatic species. Phenyl also has application as an…

  • In a reversed-phase mode, Cyano columns are the most polar and least retentive of all reversed-phase packings. Extremely hydrophobic compounds, which do not elute on standard C18 and C8 packings with typical reversed-phase eluents, can be chromatographed using Cyano columns. In addition, the unique…

  • J'sphere offers a choice from three kinds of ODS made from the same silica gel base, each with different ligand coverage. Differences in ligand coverage considerably affect the hydrophobic retention behavior of solutes, as well as the separation behavior resulting from solute functional groups or…

  • YMC-Pack ODS-A has a highly endcapped surface structure and appropriate hydrophobicity for separation of a wide range of compounds. It is produced under strict quality control with respect to 50 or more parameters in order to ensure stable quality. This product is highly regarded as the standard…

Compare Tool

Select up to 3 products