Columns

Compare Tool

Select up to 3 products

1 - 32 of 197
Sort
View
Show
  • nonpolar phase; Crossbond dimethyl polysiloxane General-purpose columns for solvent impurities, PCB congeners (e.g., Aroclor mixes), simulated distillation, arson accelerants, gases, natural gas odorants, sulfur compounds, essential oils, hydrocarbons, semivolatiles, pesticides, oxygenates. …

  • Ultra HPLC Columns The Ultra line represents Restek’s broadest selection of stationary phases on a single silica support. Made of high-purity, type-B silica that minimizes activity and creates high-density bonding, these columns are designed for selective and reliable HPLC applications. …

  • polar phase; Crossbond acid-deactivated Carbowax polyethylene glycol—for acidic compounds Stabilwax-DA bonded polyethylene glycol has an acidic functionality incorporated into the polymer structure. This permits analysis of acidic compounds without derivatization, significantly reduces…

  • Strength-tested Inexpensive Coiled in 7-inch diameters, banded in 5-meter sections, and mounted in a Restek cage

  • proprietary Crossbond diphenyl/dimethyl polysiloxane phase MXT-Volatiles columns were the first columns designed specifically for analyses of the 34 volatile organic pollutants listed in U.S. EPA Methods 601, 602, and 624. With these columns, you can quantify all compounds listed in these…

  • low- to midpolarity phase; Crossbond diphenyl dimethyl polysiloxane MXT-20 polymer is synthesized to exacting standards. All residual catalysts and low molecular weight fragments are removed from the polymer, providing a tight monomodal distribution and extremely low bleed. …

  • low- to midpolarity phase The unique polarity of "624" columns makes them ideal for analyses of volatile organic pollutants. Although the MXT-502.2 column is recommended in many methods, MXT-624 columns offer the best separation of the early-eluting gases. Application-specific…

  • low- to midpolarity phase General-purpose columns for residual solvents, alcohols, oxygenates, and volatile organic compounds. Temperature range: -20°C to 280°C. Equivalent to USP G43 phase. 4.5" standard coil diameter.

  • Viva HPLC Columns: 3 or 5 µm particles; 300 Å pore size Excellent for separating peptides or proteins Rugged, spherical particles with 300 Å pore size High proportion of pore/surface area available to large molecules Viva columns are based on a wide pore material…

  • Ultra HPLC Columns The Ultra line represents Restek’s broadest selection of stationary phases on a single silica support. Made of high-purity, type-B silica that minimizes activity and creates high-density bonding, these columns are designed for selective and reliable HPLC applications. …

  • Ultra HPLC Columns The Ultra line represents Restek’s broadest selection of stationary phases on a single silica support. Made of high-purity, type-B silica that minimizes activity and creates high-density bonding, these columns are designed for selective and reliable HPLC applications. …

  • Particle: 5 μm, spherical Pore Size: 60 Å Carbon Load: proprietary End-cap: no Surface Area: 450 m 2 /g pH Range: 2.5 to 8 Maximum Temperature: 80 °C

  • midpolarity phase; Crossbond trifluoropropylmethyl polysiloxane Rtx-200 columns have accomplished many difficult separations not possible on any other bonded stationary phase. Many analysts consider these the best, most inert midpolarity columns available. The trifluoropropylmethyl polysiloxane…

  • low-polarity phase; Crossbond diphenyl dimethyl polysiloxane The diphenyl dimethyl polysiloxane stationary phase is the most popular GC stationary phase and is used in a wide variety of applications. All residual catalysts and low molecular weight fragments are removed from the MXT-5 polymer,…

  • nonpolar phase; Crossbond dimethyl polysiloxane MXT-1 columns exhibit long lifetime and very low bleed at high operating temperatures. A proprietary synthesis process eliminates residual catalysts that could cause degradation and increase bleed. General-purpose columns for solvent…

  • Developed specifically for challenging analyses of polycyclic aromatic hydrocarbons (PAHs). The Pinnacle II PAH stationary phase incorporates a proprietary C18 bonding that enables unique shape selectivity to baseline-resolve all 16 PAHs listed in U.S. EPA Method 610 plus two other routinely…

  • Viva HPLC Columns: 3 or 5 µm particles; 300 Å pore size Excellent for separating peptides or proteins Rugged, spherical particles with 300 Å pore size High proportion of pore/surface area available to large molecules Viva columns are based on a wide pore material…

  • midpolarity phase; Crossbond diphenyl dimethyl polysiloxane Rxi fused silica capillary GC columns were designed specifically to be the best columns available, for exceptional inertness, ultra-low bleed, and reproducible retention and selectivity. In addition to outstanding performance, this…

  • highly polar phase; 1,2,3-tris[2-cyanoethoxy]propane—not bonded Most gasolines contain aliphatic hydrocarbons up to n-dodecane (C12). To improve identification of the aromatics and oxygenates, it is desirable to elute benzene after C11 and toluene after C12. The extremely polar Rt-TCEP…

  • Advantages of metal MXT PLOT columns include: Can be made in small coil diameters—perfect for tight spaces. Rugged material withstands rough handling and shock. Designed for robust performance in process GCs and field instruments. Available in 3.5"-coil diameter or…

  • Restek chemists became the first to combine the speed of superficially porous particles (also known as SPP or “core-shell” particles) with the resolution of highly selective USLC technology. This new breed of chromatographic column allows you to more easily achieve peak separation and…

  • Easy scale-up from Restek analytical columns Popular bonded phases Restek makes it easy to scale up your separations. We offer a wide range of semipreparative and preparative-scale columns packed with many of our popular Ultra, Allure, Pinnacle DB, and Viva bonded phases on a 5 μm…

  • midpolarity phase; Crossbond trifluoropropylmethyl polysiloxane General-purpose columns for solvents, Freon fluorocarbons, alcohols, ketones, silanes, and glycols. Excellent confirmation column with an Rtx-5 column, for phenols, nitrosamines, organochlorine pesticides, chlorinated…

  • proprietary Crossbond phase Using sophisticated computer modeling software, we created two stationary phases for separating the 53 organophosphorus pesticides (OPP) listed in EPA Method 8141. Separation is improved and analysis time is significantly reduced, compared to other columns. The…

  • nonpolar phase; Crossbond dimethyl polysiloxane Rxi fused silica capillary GC columns were designed specifically to be the best columns available, for exceptional inertness, ultra-low bleed, and reproducible retention and selectivity. In addition to outstanding performance, this combination of…

  • Ultra HPLC Columns The Ultra line represents Restek’s broadest selection of stationary phases on a single silica support. Made of high-purity, type-B silica that minimizes activity and creates high-density bonding, these columns are designed for selective and reliable HPLC applications. …

  • Roc HPLC columns are built to be the cornerstone for your LC lab. These solid, reliable columns are pressure rated for any 400 bar HPLC system and deliver the peak shape, reproducibility, ruggedness, and performance you demand for all of your conventional HPLC applications. An exceptional value,…

  • proprietary Crossbond phase Isomer specificity for 2,3,7,8-TCDD and 2,3,7,8-TCDF achieved with one GC column. Thermally stable to 340°C for longer lifetime. Unique selectivity for toxic dioxin and furan congeners allows use as a confirmation GC column.

  • midpolarity phase; Crossbond phenyl methyl polysiloxane The high thermal stability of Rtx-50 columns makes dual-column analysis possible with common phases such as Rtx-1 or Rtx-5MS. General-purpose columns for pesticides, herbicides, rosin acids, phthalate esters, sterols Equivalent to…

  • midpolarity proprietary Crossbond phase General-purpose columns with unique selectivity for pesticides, PAHs, or other semivolatiles. Ideal for low/trace-level analyses. Low-bleed, high-resolution columns with unique selectivity. Wide temperature range: 20°C to 340°C

  • midpolarity phase; Crossbond 35% diphenyl/65% dimethyl polysiloxane Active basic compounds that otherwise require derivatization, or an alternative analytical technique, can be analyzed on an Rtx-35 Amine column. The tubing surface is chemically altered to reduce tailing of basic compounds,…

Compare Tool

Select up to 3 products