PerkinElmer Chromatography Columns
-
Elite 608 capillary column 75m x 0.32mm, 0.50µm
PerkinElmerThermally stable to 340°C Low column bleed - ideally suited for ECD and GC/MS analysis
-
-
PerkinElmer pioneered the development of Fast HPLC and introduced the popular 3 m particle size “3 x 3” Columns (33 mm x 4.6 mm) in the 1980s. The “3 x 3” columns are capable of very rapid analysis and still they are still very popular in many laboratories because of the economical price and…
-
Brownlee Pecosphere columns are packed with rugged, high purity silica. Reduced activity (RA) version is especially suited for analysis of basic analytes. Requires holder P/N 07150029.
-
Silica (SI-S) Supra-Clean Spherical Silica-based Solid Phase Extraction (SPE) products are recommended for extracting polar compounds when analyzing aldehydes, amines, pesticides, herbicides, carotenoids, fat soluble vitamins, baflatoxins, fatty acids, and phospholipids. SPE Format: Straight PP…
-
-
Equivalent to USP G43 phase Temperature range -60°C to 330/350°C
-
-
Elite 624 capillary column 30m x 0.45mm, 2.55µm
PerkinElmerTemperature range -20°C to 240°C Equivalent to USP G43 phase
-
The Elite-SimDist columns are specifically for the simulated distillation application. The phase is specifically processed for dimethylpolysiloxane.
-
Elite 1301 capillary column 10m x 0.18mm, 0.40µm
PerkinElmerTemperature range -20°C to 280°C Equivalent to USP G43 phase
-
PerkinElmer Elite-XLB (Specialty phase for GC/MS with exceptionally low bleed) Series Capillary Columns, Length: 30m, Inner Diameter: 0.32mm, Film Thickness: 0.50m, Temperature Limits:30 to 340/360C
-
SPE Supra-CleanC18-S Column, 500 mg/3 mL
PerkinElmerC18-S Supra-CleanSpherical Silica-based Solid Phase Extraction (SPE) Columns are recommended for extracting mid-polar to non-polar compounds when analyzing drugs and drug metabolites in biological matrices, trace organic material in water, and toxins in food. SPE Format: Straight PP TubeMedia…
-
Temperature range -60oC to 200 oC
-
Brownlee Polypore ® columns are 10 mm, microporous polymer based columns especially suited for the analysis of sugars and organic acids.
-
Supra-Clean Strong Anion Exchange (SAX) Solid Phase Extraction (SPE) products are for extracting acidic compounds.
-
Elite-1MS capillary column, 30m x 0.25mm, 0.25µm
PerkinElmerEquivalent to USP G1, G2 and G38 phases Temperature range -60°C to 350/400°C
-
-
Elite-1 capillary column, 15m x 0.53mm, 3.00µm
PerkinElmerEquivalent to USP G1, G2 and G38 phases Temperature range -60°C to 350/400°C
-
Supra-Clean Florisil Pesticide (FL-S) SPE products are recommended for extracting polar compounds when analyzing pesticides.
-
Temperature range -60oC to 200 oC
-
Brownlee Aquapore conventional columns built on a 7 m, 300 Angstrom pore size silica. The OD-300 and RP-300 are reverse-phase silicas modfied with C18 and C8, respectively. AX-300 is a weak anion exchanger that is composed of a crosslinked polyethyleneimine phase bonded on the silica surface.…
-
Universal BIO C18PP 5UM 250X4.6MM HPLC Column
PerkinElmerUniversal BIO C18PP 5UM 250X4.6MM HPLC Column
-
Elite-35 capillary column, 30m x 0.53mm, 0.50µm
PerkinElmerEquivalent to USP G42 phase Temperature range 40°C to 320°C
-
Brownlee Pecosphere columns are packed with rugged, high purity silica. Requires holder P/N 07150030
-
Elite-17 capillary column, 20m x 0.18mm, 0.18µm
PerkinElmerEquivalent to USP G3 phase Temperature range 40°C to 320°C
-
Brownlee Spheri-5 amino is based on a small pore silica, monofunctional, optimized for separating small molecules. Requires holder P/N 07150015 without guard column or P/N 07150017 with a guard column.
-
Extreme Capacity (XC) polystyrene-divinylbenzene Supra-Poly® Spherical Polymer-based Solid Phase Extraction (SPE) products are recommended for extracting polar and non-polar compounds when analyzing drugs and drug metabolites biological fluids. The 96 Well Plates are available in several media…
-
Deactivated Tubing is perfect for making guard columns and retention gaps. Use Splitters(p/n N9303448) and connectors (p/n N9302149) to attach tubing to polymide coated columns.
-
Hydrophilic (ATH) Supra-Poly Spherical Polymer-based Solid Phase Extraction (SPE) products are recommended for extracting mid to non-polar compounds when analyzing mid-polar and non-polar compounds in aqueous and organic solvents. SPE Format: Straight PP Tube Media Weight: 200 mg Format…
-
Elite-5MS capillary column 60m x 0.32mm, 0.25µm
PerkinElmerTemperature range -60oC to 350 oC Equivalent to USP G27, G36 phases
-
Elite-1 capillary column, 105m x 0.45mm, 2.55µm
PerkinElmerEquivalent to USP G1, G2 and G38 phases Temperature range -60°C to 350/400°C