Agilent Technologies Gas Chromatography Columns

Compare Tool

Select up to 3 products

Sort
View
Show

Agilent Technologies

Efficient LC Solutions that deliver the fast, reproducible results you need


  • Put an end to frustration about GC capillary column connections! With the novel design of our proprietary UltiMetal Plus Flexible Metal ferrule, you can confidently make leak free column unions to capillary flow technology (CFT) devices. These new metal ferrules fix the problems of column breakage…

  • Agilent Technologies

    (50%-Phenyl)-methylpolysiloxane Midpolarity slightly more polar than HP-50+ Suitable for confirmational analyses Bonded and cross-linked Solvent rinsable Temperature limits are 40° to 260/280°C or 40° to 280/300°C Equivalent to USP Phase G3 HP-50+, Rtx-50,…

  • Agilent Technologies

    Agilent J&W DB-1 is nonpolar and low-bleed, and operates under high temperature limits. It is an excellent choice for general purpose use in a wide variety of applications. Precision-engineered DB-1 is bonded, crosslinked and solvent rinsable, and is equivalent to USP phase G2. This product is…

  • Agilent Technologies

    Agilent J&W Select PAH is the first capillary column that provides a single solution for PAH analysis by separating all the isomers, thereby avoiding false positives and inaccurate results. It provides easy, fast, and accurate quantification of PAHs in environmental and food samples by…

  • Agilent Technologies

    Capillary ferrules are packaged in dial packs which deliver one ferrule at a time, keeping the others clean and ready for use. The dial packaging has been tested to ensure no out gassing of contaminants, including phthalates. *These ferrules are recommended for use with Agilent GC/MS…

  • Agilent Technologies

    Polyethylene glycol (PEG) Close equivalent to USP Phase G16 High polarity Lower temperature limit of 20°C is lowest of any bonded PEG phase; improves resolution of low boiling point analytes Column-to-column repeatability Bonded and cross-linked Solvent rinsable …

  • Agilent Technologies

    100% Dimethylpolysiloxane Identical selectivity to HP-1 Non-polar Low bleed characteristics General purpose column Improved signal-to-noise ratio for better sensitivity and mass spectral integrity Bonded and cross-linked Solvent rinsable Temperature range:…

  • Agilent Technologies

    Virtually equivalent to (50%-Cyanopropylphenyl)-methylpolysiloxane Mid/high polarity Excellent for separations of cis- and trans-fatty acid methyl esters (FAMEs) Low bleed Bonded and cross-linked Solvent rinsable Close equivalent to USP Phase G7 Similar Phases:…

  • Agilent Technologies

    Polyethylene glycol (PEG) Extended Temperature Range (etr) High polarity Excellent column-to-column repeatability Bonded and cross-linked Solvent rinsable Close equivalent to USP Phase G16 Similar Phases: HP-20M, SUPELCOWAX 10, CP-WAX 52 CB, SUPEROX II, CB-WAX,…

  • Agilent Technologies

    DX-1: 90% Dimethylpolysiloxane - 10% Polyethylene Glycol DX-4: 15% Dimethylpolysiloxane - 85% Polyethylene Glycol Because DX series GC columns are not bonded and cross-linked, we do not recommend solvent rinsing. Agilent Technologies products are intended for sale/shipment within…

  • Agilent Technologies

    100% Dimethylpolysiloxane Configured for the analysis of petroleum process products PONA, PIANO High resolution Bonded and cross-linked Solvent rinsable Similar Phases: Petrocol DH, HP-PONA, SPB-1, 007-1, Rtx-1, MXT-1 100 psi regulator required to reach optimum…

  • quick-ship

    Agilent Technologies

    Equivalent to a (5%-Phenyl)-methylpolysiloxan Non-polar Specially processed to exhibit excellent inertness for EPA Semivolatiles Methods 625, 1625, 8270 and CLP protocols* Surpasses EPA performance criteria for semivolatiles Inert for base, neutral and acidic compounds High…

  • Agilent Technologies

    SE-30: 100% Dimethylpolysiloxane SE-54: (5%-Phenyl)(1%-Vinyl)-methylpolysiloxane Because SE series GC columns are not bonded or cross-linked, we do not recommend solvent rinsing. Agilent Technologies products are intended for sale/shipment within the US only. International customers…

  • Agilent Technologies

    Agilent J&W GS-CarbonPLOT uses a high stability, carbon-layer stationary phase to deliver unique selectivity for inorganic and organic gases. The column features an extended temperature limit to 360 °C. The retention stability of GS-CarbonPLOT is not affected by water, and the column is…

  • Agilent Technologies

    Virtually equivalent to (50%-Phenyl)-methylpolysiloxane 320°/340°C upper temperature limit Very low bleed midpolarity, suitable for GC/MS Exhibits inertness to active compounds Enhanced mass spectral integrity Bonded and cross-linked Solvent rinsable Best…

  • Agilent Technologies

    100% Dimethylpolysiloxane Non-polar Specially processed for extended temperature limit of 400°C High temperature, polyimide-coated, fused silica tubing Excellent peak shape and faster elution times for high boilers Bonded and cross-linked Solvent rinsable …

  • Agilent Technologies

    Specifically designed for the analysis of volatile priority pollutants No cryogenics needed for U.S. EPA Method 502.2 Excellent for U.S. EPA Methods: 501.3, 502.2, 503.1, 524.2, 601, 602, 8010, 8015, 8020, 8240 and 8260 Exhibits inertness to active compounds Bonded and cross-linked Solvent…

  • 100% Dimethylpolysiloxane Non-polar Low bleed characteristics Improved signal-to-noise ratio for better sensitivity and mass spectral integrity Bonded and cross-linked and solvent rinsable Agilent Technologies products are intended for sale/shipment within the US only. International…

  • Agilent Technologies

    Least “polar” Alumina phase Aluminum oxide deactivated with KCl Good choice for light hydrocarbon analysis Good resolution of propadiene and butadiene from ethylene and propylene streams Similar Phases: CP-Al2O3/KCl PLOT, Rt-Alumina PLOT,…

  • Agilent Technologies

    50%-Cyanopropyl)-methylpolysiloxane High polarity Designed for separation of fatty acid methyl esters (FAMEs) Excellent resolution for cis- and trans-isomers Bonded and cross-linked Solvent rinsable Replaces HP-23 Close equivalent to USP Phase G5 Similar…

  • Agilent Technologies

    100% Dimethylpolysiloxane “Boiling point” phase for high temperature simulated distillation Durable stainless steel tubing 430°C upper temperature limit Distillation range of C6 to C110 Low bleed - even at 430°C Bonded and cross-linked Solvent…

  • Agilent Technologies

    (50%-Phenyl)-methylpolysiloxane Midpolarity Extended upper temperature limit of 365°C High temperature, polyimide-coated, fused silica tubing Excellent peak shape and faster elution times for high boilers Improved resolution for triglycerides Ideal for…

  • Agilent Technologies

    Agilent J&W DB-35ms Ultra Inert is a mid-polar column, for applications where different selectivity is needed for enhanced separations, including pesticide analysis and drugs of abuse testing. DB-35ms Ultra Inert quantifies components at a lower level, with broader linearity and optimized…

  • Agilent Technologies

    Specifically designed for the analysis of chlorinated pesticides and PCBs U.S. EPA Methods: 608, 508, 8080 Excellent inertness and recoveries without pesticide breakdown Bonded and cross-linked Solvent rinsable Exact replacement of HP-608 Similar Phases: SPB-608,…

  • Agilent Technologies

    Low/midpolarity Exact replacement of HP-PAS1701 Specifically designed and processed for the analysis of organochlorine pesticides ECD tested to assure minimal pesticide breakdown and low ECD bleed Bonded and cross-linked Solvent rinsable Similar Phases: SPB-1701,…

  • Agilent Technologies

    GC capillary columns are typically wound on 7 inch cages that fit into standard-sized GCs like the 6890. The 6850 GC has a smaller oven which requires the use of columns wound on a smaller cage diameter. 100% Dimethylpolysiloxane Non-polar Excellent general purpose column …

  • Agilent Technologies

    Extend the life of your analytical GC or GC/MS column by using a guard column reliably connected to you analytical column with our high performance capillary GC column connector, the Ultimate Union. New-technology Ultimate Union kits eliminate the “arts and crafts” involved in…

  • Agilent Technologies

    100% Dimethylpolysiloxane Identical selectivity to DB-1 Non-polar Very low bleed characteristics, ideal for GC/MS Improved acid performance compared to standard 100% Dimethylpolysiloxane columns Improved signal-to-noise ratio for better sensitivity and mass spectral integrity …

  • DB-1ms is an excellent general-purpose GC column and ideal for GC/MS of active analytes commonly found in drug screening and environmental analyses. The Ultra Inert 1ms GC columns set the new industry standards for consistent column inertness and exceptionally low column bleed. These columns…

  • Agilent Technologies

    Agilent J&W DB-1 is nonpolar and low-bleed, and operates under high temperature limits. It is an excellent choice for general purpose use in a wide variety of applications. Precision-engineered DB-1 is bonded, crosslinked and solvent rinsable, and is equivalent to USP phase G2. This product is…

  • Agilent Technologies

    GC capillary columns are typically wound on 7 inch cages that fit into standard-sized GCs like the 6890. The 6850 GC has a smaller oven which requires the use of columns wound on a smaller cage diameter. (5%-Phenyl)-methylpolysiloxane Identical selectivity to HP-5 Non-polar …

  • Agilent Technologies

    (5%-Phenyl)-methylpolysiloxane Non-polar Wide range of applications High temperature limits: -60° to 325°C isothermally, -60° to 350°C programmed. -60° to 300°C isothermally, -60° to 320°C programmed for 0.53 mm columns -60° to 260°/280°C…

Compare Tool

Select up to 3 products