  • CHROMABOND® HR-XCW

    MACHEREY-NAGEL

    Weak carboxylic acid modified polymeric cation exchanger for SPE Features Base material spherical PS/DVB copolymer, pore size 50–60 Å, particle sizes 45 µm or 85 µm (standard), very large specific surface 850 m2/g, pore volume 1.2–1.4 cm3/g, pH stability…

  • AFFINIMIP® SPE Selective Cartridges for Patulin

    Affinisep

    Affinimip SPE is a selective solid phase extraction based upon molecularly printed polymers (MIP). It combines the advantages of Immune-affinity columns in terms of selectivity and a classic solid phase extraction (SPE) in terms of robustness and costs. This selectivity and robustness combines to…

  • CHROMABOND® Easy

    MACHEREY-NAGEL

    Polar, bifunctionally modified polystyrene-divinylbenzene copolymer Features Polar modified polystyrene-divinylbenzene copolymer with a weak anion exchanger, specific surface 650–700 m2/g, particle size 80 µm, pore size 50 Å, pH stability 1–14 The Easy…

  • CHROMABOND® QuEChERS

    MACHEREY-NAGEL

    Special products for determination of pesticides in food samples QuEChERS method and pre-mixes Within a few years after its development by Anastassiades et al. the QuEChERS method has gained a leading position for the determination of pesticide residues in food samples by GC-MS or LC-MS,…

  • CHROMABOND® Flash RS C18 ec Cartridges

    MACHEREY-NAGEL

    Ideal for Flash separations from 10 mg up to 300 g Features For convenient operation and reliable upscaling the complete program of ready-to-use Flash cartridges for the Isco Companion® and other Teledyne Isco CombiFlash® systems, or as stand-alone version for all…

  • SampliQ Silica C8/Si-SCX Mixed Mode SPE Cartridges

    Agilent Technologies

    Generally used to retain polar analytes Solvent retention generally decreases as solvent becomes more polar A great option when more generally-used sorbents, such as C18, don’t perform specifically enough for your particular application The SampliQ Mixed-Mode Reversed-Phase SPE…

  • SampliQ Silica C18 Endcapped SPE Cartridges

    Agilent Technologies

    Reversed Phase (Non-Polar) 25% carbon loading Silica-based particles reduce pressure drop and increase flow reproducibility Average particle size of 45 µm and pore diameter of 60Å to reduce pressure drop and increase flow reproducibility Agilent’s trifunctional…

  • Oasis® HLB Plus Light Cartridges

    Waters

    Oasis HLB sample extraction products contain a polymeric water-wettable reversed-phase sorbent. When combined with a simple, generic methodology, HLB sorbent allows the extraction of a wide range of compounds in various matrices with high reproducible recoveries.

  • CHROMABOND® PL

    MACHEREY-NAGEL

    SPE phase for the selective removal of phospholipids from biological samples (e.g., plasma or serum) Features Specially developed SPE phase for the preparation of bioanalytical samples CHROMABOND® PL products are designed for internal protein precipitation. External protein…

  • Spare Filters For Extrelut NT 3 Prepacked Glass Columns

    MilliporeSigma

    Includes: 100 Units

  • CHROMABOND® Alox A

    MACHEREY-NAGEL

    CHROMABOND® SPE products Features More than 50 different sationary phases available e.g., silica gel based: unmodified, C8, C18, NH2, CN; Polyermic material: HR-X, HLB, PA; mixed-mode, special combinations, aluminum oxide, kieselguhr (XTR) etc. NP, RP, ion exchanger and for special…

  • CHROMABOND® Tetracycline SPE Columns

    MACHEREY-NAGEL

    Special phase for SPE enrichment of tetracyclines Features Silica phase with special octadecyl modification, tested for tetracyclines, constant recovery rates for the title compounds (every batch individually tested) Recommended application: tetracyclines from biological samples

  • Lichrolut® Extraction Unit Accessories

    MilliporeSigma

  • SampliQ Silica C18 ODS SPE Cartridges

    Agilent Technologies

    Reversed Phase (Non-Polar) 24% carbon loading Silica-based particles reduce pressure drop and increase flow reproducibility Average particle size of 45 µm and pore diameter of 60Å to reduce pressure drop and increase flow reproducibility Agilent’s trifunctional…

  • CHROMABOND® PS

    MACHEREY-NAGEL

    Polymer-based SPE phases for RP and ion chromatography Features Base material: high purity polystyrene-divinylbenzene copolymers (PS/DVB), pore size 100 Å, particle size 100 µm very low degree of swelling, thus very well suited for chromatography reliable function…

  • CHROMABOND® XTR

    MACHEREY-NAGEL

    Kieselguhr phase for liquid-liquid extraction Features Base material coarse-grained kieselguhr (also known as diatomaceous earth, hydromatrix, celite) large pore size, high pore volume, constantly high batch-to-batch quality pH working range 1–13 Application: …

  • Sep-Pak® Accell Plus QMA Vac Cartridges

    Waters

    Sep-Pak Accell Plus QMA Vac cartridges contain a silica-based, hydrophilic, strong anion-exchanger with large pore size (300Å). The cartridges are designed for extraction of anionic analytes in aqueous and non-aqueous solutions. The large pore size makes it ideal for isolation of larger…

  • CHROMABOND® SA

    MACHEREY-NAGEL

    Features More than 50 different sationary phases available e.g., silica gel based: unmodified, C8, C18, NH2, CN; Polyermic material: HR-X, HLB, PA; mixed-mode, special combinations, aluminum oxide, kieselguhr (XTR) etc. NP, RP, ion exchanger and for special applications Different…

  • CHROMABOND® Empty Columns

    MACHEREY-NAGEL

    For individual packing of SPE columns with CHROMABOND® adsorbents.

  • Sep-Pak® Accell Plus QMA Plus Light Cartridges

    Waters

    Sep-Pak Accell Plus QMA Plus Light cartridges contain a silica-based, hydrophilic, strong anion-exchanger with large pore size (300Å). The cartridges are designed for extraction of anionic analytes in aqueous and non-aqueous solutions. The large pore size makes it ideal for isolation of…

  • CHROMABOND® Na2SO4/Florisil® SPE Columns

    MACHEREY-NAGEL

    Combination phase for SPE of hydrocarbons from water acc. to DIN H53 / ISO DIS 9377-4 Features Special combination phase of sodium sulfate and Florisil® Recommended application: hydrocarbons from drinking, surface and waste waters

  • SampliQ Carbon SPE Cartridges

    Agilent Technologies

    Generally used to retain polar analytes Solvent retention generally decreases as solvent becomes more polar A great option when more generally-used sorbents, such as C18, don’t perform specifically enough for your particular application SampliQ Carbon (graphitized) sorbents…

  • TELOS® Polar SPE Cartridges

    Kinesis

    Extract polar analytes from nonaqueous matrices Use the TELOS polar (normal phase) SPE cartridges to retain analytes of interest or to remove polar interferences from the sample. Columns with Florisil® PR grade (magnesium silicate) sorbent have larger particle size than NH2 and are…

  • SampliQ Silica SPE Cartridges

    Agilent Technologies

    Normal Phase (Polar) Average particle size of 45 µm and pore diameter of 60Å to reduce pressure drop and increase flow reproducibility Agilent’s trifunctional bonding process provides more stability over monomeric bonding Manufactured to Agilent’s rigorous quality standards…

  • CHROMABOND® Florisil®

    MACHEREY-NAGEL

    Magnesium silicate for SPE Features Matrix magnesium silicate (MgO – SiOH 15:85), high purity, particle size 150–250 µm Recommended application: organic tin compounds, aliphatic carboxylic acids, PCBs, PAHs

  • Replacement Filter For Extrelut NT 20 HDPE Columns

    MilliporeSigma

    Includes: 50 Units

  • BAKERBOND spe™ Disposable Extraction Columns

    Avantor - J.T.Baker®

    Baker Disposable, Pre-Packed Extraction Columns Polypropylene extraction columns prepacked with sorbent Packing is held between two 20 mm polyethylene frits Sorbent weight ranges from 100 to 1000 mg and column reservoir capacity is 1, 3 or 6 mL, as indicated in listings below …

  • CHROMABOND® C18

    MACHEREY-NAGEL

    Features More than 50 different sationary phases available e.g., silica gel based: unmodified, C8, C18, NH2, CN; Polyermic material: HR-X, HLB, PA; mixed-mode, special combinations, aluminum oxide, kieselguhr (XTR) etc. NP, RP, ion exchanger and for special applications Different…

  • CHROMABOND® Reservoir Columns

    MACHEREY-NAGEL

    Reservoir columns for application of medium-size samples.

  • AFFINIMIP® SPE Catecholamines Selective Cartridges

    Affinisep

    Affinimip SPE is a selective solid phase extraction based upon molecularly printed polymers (MIP). It combines the advantages of Immune-affinity columns in terms of selectivity and a classic solid phase extraction (SPE) in terms of robustness and costs. This selectivity and robustness combines to…

  • AFFINIMIP® SPE PAHs Selective Cartridges

    Affinisep

    Affinimip SPE is a selective solid phase extraction based upon molecularly printed polymers (MIP). It combines the advantages of Immune-affinity columns in terms of selectivity and a classic solid phase extraction (SPE) in terms of robustness and costs. This selectivity and robustness combines to…