Chromatography Columns
-
low-polarity phase; Crossbond diphenyl dimethyl polysiloxane The diphenyl dimethyl polysiloxane stationary phase is the most popular GC stationary phase and is used in a wide variety of applications. All residual catalysts and low molecular weight fragments are removed from the Rtx-5 polymer,…
-
Jacketed CHROMAFLEX® Columns
DWK Life Sciences (Kimble)Jacketed CHROMAFLEX® columns are provided with an acrylic water jacket to provide thermal control of temperature-sensitive chromatographic separations. The acrylic jacket also acts as a safety shield. Threaded Recommended sterilization is with ethylene oxide, 2N NaOH or…
-
DB-FFAP
Agilent TechnologiesNitroterephthalic acid modified polyethylene glycol High polarity Designed for the analysis of volatile fatty acids and phenols Bonded and cross-linked Solvent rinsable Close equivalent to USP Phase G35 Temperature limits: 40° to 250°C NOTE: Agilent does…
-
-
HP-5
Agilent Technologies(5%-Phenyl)-methylpolysiloxane Non-polar Wide range of applications High temperature limits: -60° to 325°C isothermally, -60° to 350°C programmed. -60° to 300°C isothermally, -60° to 320°C programmed for 0.53 mm columns -60° to 260°/280°C…
-
YMC-Pack TMS columns are bonded with trimethylmonochlorosilane to create a phase with intermediate polarity for analysis of extremely hydrophobic compounds using conventional reversed-phase solvents and highly polar compounds using highly aqueous solvents. The unique chemistry of TMS is also…
-
Micropacked GC Columns
RestekIncreased efficiency over traditional packed columns. Higher capacity than PLOT columns. Made from inert, flexible SilcoSmooth tubing. Wide range of packings available. Standard coils fit all instruments. No special instrument configurations required. Efficient, Inert, and…
-
GS-Gaspro
Agilent TechnologiesBonded PLOT column technology Suitable for light hydrocarbons and sulfur gas Retention stability not affected by water Separates CO and CO2 on a single column Ideal PLOT column for CG/MS - no particles Temperature limits: -80° to 260°/300°C …
-
HP-5
Agilent TechnologiesGC capillary columns are typically wound on 7 inch cages that fit into standard-sized GCs like the 6890. The 6850 GC has a smaller oven which requires the use of columns wound on a smaller cage diameter. (5%-Phenyl)-methylpolysiloxane Non-polar Excellent general purpose column …
-
Restek chemists became the first to combine the speed of superficially porous particles (also known as SPP or “core-shell” particles) with the resolution of highly selective USLC technology. This new breed of chromatographic column allows you to more easily achieve peak separation and…
-
polar phase; Crossbond cyanopropylmethyl phenylmethyl polysiloxane The cyanopropyl-containing Rtx-225 phase is slightly less polar than bonded polyethylene glycol (PEG) phases, but it can be used for many of the same applications. Improvements to the Rtx-225 polymer have increased thermal…
-
2,3-di-O-methyl-6-O-tert-butyl dimethylsilyl beta cyclodextrin added into 14% cyanopropylphenyl/86% dimethyl polysiloxane By adding β or γ cyclodextrin to our bonded Rtx-1701 stationary phase, we greatly enhance overall utility and column lifetime for our chiral columns, compared to…
-
NUCLEOGEL® ION 300 OA HPLC Columns
MACHEREY-NAGELNUCLEOGEL® ION 300 OA Polymer-based HPLC phases for separation of sugars Features Sulfonated spherical PS/DVB resins in H+ ionic form · USP L17 Mean particle size 10 µm Pore size 100 Å Separation mechanism includes steric exclusion, ligand exchange and…
-
CDS Empore™ 660: 96-Well Sealing Tape Pad
CDS Empore™Good to remove visible particulates (>10um) from samples in the 96-well plate format (>98% removal), while maintaining excellent flow characteristics.
-
BAKERBOND spe™ PolarPlus® C18 (Octadecyl) Disposable Extraction Columns, SPE
Avantor - J.T.Baker®For Polar Compounds CAS Number: 71889-02-6
-
Zorbax Reversed-Phase Liquid Chromatography Column
Agilent TechnologiesThe ZORBAX column family is one of the most popular high-performance liquid chromatography (HPLC) column families for reversed-phase HPLC. ZORBAX columns are based on traditional fully porous particles and offer the highest loading capacity and resolution. From Eclipse Plus, Eclipse XDB,…
-
Molecular Sieve Columns
RestekMolecular sieve packed columns easily separate permanent gases at above-ambient temperatures. Restek’s R&D chemists have developed a process for preparing molecular sieve packings, which results in excellent batch-to-batch reproducibility. In addition, our molecular sieves are…
-
Ultra 1 & Ultra 2
Agilent TechnologiesUltra 1: 100% Dimethylpolysiloxane Ultra 2: (5%-Phenyl)-methylpolysiloxane Non-polar Bonded and cross-linked Solvent rinsable HP-1 and HP-5 with tighter specifications for retention index and capacity factors Temperature range: -60° to 325°/350°C …
-
GC Ultra Inert Column
Agilent TechnologiesDB-624 Ultra Inert (UI) column is optimal for the fast & accurate analysis of volatile organic compounds (VOCs) in pharmaceutical, environmental, food, and industrial chemical applications by GC and GC/MS. Following from its predecessor, this Ultra Inert version of the industry standard DB-624 is…
-
Guard Cartridge Holder
Agilent TechnologiesAgilent Technologies products are intended for sale/shipment within the US only. International customers should contact their local Agilent Technologies distributor to place orders for Agilent Technologies products.
-
InfinityLab Poroshell 120 UHPLC Guard Column
Agilent TechnologiesInfinityLab Poroshell 120 superficially porous columns for reversed-phase liquid chromatography (LC) separations offer exceptional efficiency and reliability. Twenty chemistries - from various C18 columns to other unique phases - are available in up to three particle diameters: 1.9 µm, 2.7 µm, and…
-
Lowox 10m x 0.53mm x 10um
Agilent TechnologiesAgilent Technologies products are intended for sale/shipment within the US only. International customers should contact their local Agilent Technologies distributor to place orders for Agilent Technologies products.
-
Ultimate Plus Deactivated Tubing
Agilent TechnologiesUltimate Plus Deactivated Fused Silica tubing can be used as guard columns, retention gaps, transfer lines, or restrictors to improve GC flow path performance. It is engineered for optimum inertness and peak shape performance with active trace level compounds, for analysts in environmental, food…
-
Ultimate Plus Deactivated Tubing
Agilent TechnologiesUltimate Plus Deactivated Fused Silica tubing can be used as guard columns, retention gaps, transfer lines, or restrictors to improve GC flow path performance. It is engineered for optimum inertness and peak shape performance with active trace level compounds, for analysts in environmental, food…
-
GC Capillary Column
Agilent TechnologiesGas Chromatography (GC) columns are at the heart of the gas chromatograph and responsible for the separation process. GC is one of the most important and critical tools in analytical chemistry, because of its effectiveness, sensitivity and ease-of-use. GC columns contain a stationary phase,…
-
Pursuit XRs Reversed-Phase HPLC Column
Agilent TechnologiesThe Agilent Pursuit family of HPLC columns offers reliable performance in various common particle sizes and phase chemistries, including USP L1, USP L7, and USP L11. Pursuit columns are available in many dimensions, including preparative HPLC columns. In addition, both traditional (Pursuit) and…
-
Polaris HPLC MetaGuard Column
Agilent TechnologiesAgilent Polaris HPLC columns offer many polar phase chemistries designed separate mixtures of polar and nonpolar analytes reliably and with excellent peak shapes. The polar-embedded C8 and C18 bonded phases are compatible with 100% water, and offer alternative selectivities while still complying…
-
Ferrule for Varian/Bruker
Agilent TechnologiesFerrules and connectors are critical components to securing a leak-free flow path in your GC. Agilent is proud to offer a wide selection of supplies for your connection needs, including ferrules varying in size and material, unions, column connectors, and our patented self-tightening column nuts. …
-
Ultimate Plus Deactivated Tubing
Agilent TechnologiesUltimate Plus Deactivated Fused Silica tubing can be used as guard columns, retention gaps, transfer lines, or restrictors to improve GC flow path performance. It is engineered for optimum inertness and peak shape performance with active trace level compounds, for analysts in environmental, food…
-
J&W Packed Gas Chromatography Column
Agilent TechnologiesJ&W Packed Gas Chromatography (GC) Columns are designed and manufactured to offer excellent and reproducible performance for all sample types associated with packed column separations, most important in the hydrocarbon processing industry. The efficient and rigorous packing technology used in J&W…
-
Connector,LDVinter-col,SS,1/pk
Agilent TechnologiesAgilent Technologies products are intended for sale/shipment within the US only. International customers should contact their local Agilent Technologies distributor to place orders for Agilent Technologies products.
-
GC Capillary Column
Agilent TechnologiesGas Chromatography (GC) columns are at the heart of the gas chromatograph and responsible for the separation process. GC is one of the most important and critical tools in analytical chemistry, because of its effectiveness, sensitivity and ease-of-use. GC columns contain a stationary phase,…