Assay Kits

Compare Tool

Select up to 3 products

1 - 32 of 194
Sort
View
Show
  • For sensitive and high-throughput phosphate determination. Very stable reagent. High sensitivity and wide detection range (0.02 - 40 μM phosphate). Homogeneous "mix-and-measure" type high-throughput assay. Assays can be performed in tubes, cuvettes or microplates. …

  • For quantitative determination of ascorbate (ascorbic acid) and evaluation of drug effects on ascorbic acid metabolism. Linear detection range colorimetric assay 6 to 1000 μM, fluorimetric assay 1 to 100 μM ascorbic acid. Method: OD570 nm, or FL530/585 nm. Samples: Serum, plasma,…

  • For quantitative determination of fatty acid and evaluation of drug effects on its metabolism. Linear detection range colorimetric assay 7 - 1000 μM, fluorimetric assay 7 - 100 μM fatty acid. Convenient "mix-and-read" high-throughput assay. Method: OD570 nm, or FL530/585…

  • For quantitative determination of total protein. Detection range 0.06 - 1.0 mg /mL protein in 96-well plate assay. Can be readily automated to test thousands of samples per day. Low interference. Glucose, Tris, vitamins, and amino acids, DNA, RNA, salts, EDTA (<12 mM), phenol (<50…

  • For quantitative determination of glutathione peroxidase activity and evaluation of drug effects on GPX activity. Linear detection range 40 to 800 U/L GPX activity. Method: OD340 nm. Samples: Biological.

  • Deionized Water

    BioAssay Systems

    Deionized water used for preparation of samples for use with the QuantiQuik™ UreaQuick Test Strips .

  • pNPP Phosphatase Assay Kit

    BioAssay Systems

    For quantitative determination of phosphatase activity The detection limit is generally 3 ng phosphatase or below. No wash or reagent transfer steps are involved. All reagents are compatible with high-throughput liquid handling instruments. Method: OD405 nm. Samples: Protein phosphatases.

  • Acetaldehyde determination in biological and food/beverage samples. Fast and sensitive. Linear detection range (50µL sample): 0.5 µM to 60 µM acetaldehyde in 96-well plate assay. The procedure involves adding a single working reagent, and reading the absorbance after 30…

  • For quantitative bioluminescent assay for ADP:ATP ratio (apoptosis) in cells. Safe. Non-radioactive assay. Homogeneous and convenient "mix-incubate-measure" type assay. Can be readily automated to test thousands of samples per day. Method: Luminescence. Samples: Cells.

  • β-N-Acetylglucosaminidase activity determination in biological samples. Linear detection range 0.2 - 50 U/L β-N-acetylglucosaminidase. Homogeneous "mix-incubate-measure" type assay Can be readily automated to process thousands of samples per day. Method: OD405 nm.…

  • Free Amino Nitrogen determination in foods and beverages (e.g. beer, wort, wine, must, etc.) Fast and sensitive. Linear detection range (5 µL sample): 0.2 to 10 mM for 10 min reaction. Convenient and high-throughput. Homogeneous "mix-incubate-measure" type assay. Can be…

  • For quantitative determination of alcohol dehydrogenase activity and evaluation of drug effects on its metabolism. Fast and sensitive. Linear detection range (20 μL sample): 0.4 to 80 U/L for 30 min reaction. Detection Limit of 0.1 U/L for 120 min reaction. Convenient and…

  • For quantitative determination of sorbitol dehydrogenase enzyme activity. Linear detection range 0.1 - 125 U/L sorbitol dehydrogenase. Can be readily automated to process thousands of samples per day. Method: OD565 nm. Samples: Biological Samples e.g. plasma, serum, urine, tissue and…

  • For quantitative determination of phospholipid and evaluation of drug effects on its metabolism. Linear detection range colorimetric assay 3 - 200 μM, fluorimetric assay 0.6 - 20 μM phospholipid. Method: OD570 nm, or FL530/585 nm. Samples: Biological.

  • For quantitative determination of invertase/sucrase activity. Safe. Non-radioactive assay. "Mix-incubate-measure" type assay. No wash and reagent transfer steps are involved. Can be readily automated to test thousands of samples per day. Method: OD570 nm, or FL530/585 nm. …

  • For quantitative determination of total protein. Linear detection range of 0.05 - 200 μg/mL BSA. Homogeneous "mix-incubate-measure" type assay. Can be readily automated to test thousands of samples per day. Method: FL360/450 nm. Samples: Biological.

  • For quantitative determination of creatine and evaluation of drug effects on creatine metabolism. Linear detection range 4 to 1000 μM (colorimetric assay) or 0.5 to 50 μM (fluorimetric assay). Simple "mix-and-measure" procedure allows reliable quantitation of creatine…

  • For quantitative determination of bilirubin and evaluation of drug effects on bilirubin metabolism. Detection limit of 0.16 mg/dL bilirubin in 96-well plate assay. Can be readily automated to process thousands of samples per day. Method: OD530 nm. Samples: Serum.

  • For sensitive and high-throughput phosphate determination. Very stable reagent. High sensitivity and wide detection range (0.4 - 50 μM phosphate). Can be readily automated on HTS liquid handling systems. Method: OD620 nm. Samples: Enzyme reactions with free phosphate releases.

  • Determination of glucose uptake in whole cells and evaluation of effects of ligands or drugs on glucose transport. Safe. No radioactive material is used. Linear detection range 0.1 - 5 µM 2-DG6P. Can be automated as a medium throughput assay for glucose transport in cells. …

  • Determination of gliadin in food and beverage samples. Fast and Simple. Entire assay procedure takes less than three hours. Sensitive and Accurate. Quantifies gliadin in the parts per billion range. Simple Calculation. Simple calculation with linear standard curve. Method: Sandwich ELISA (OD450nm)…

  • For quantitative determination of free and total sialic acid (NANA) and evaluation of drug effects on sialic acid. Linear detection range 5 - 1000 μM sialic acid for colorimetric assays and 0.5 - 100 μM for fluorimetric assays. Method: OD549nm, or FL555/585 nm. Samples: Serum,…

  • For quantitative determination of α-mannosidase enzyme activity using a p-nitrophenol based substrate. Fast and sensitive. Linear detection range (10 μL sample): 1 to 250 U/L for a 10 minute reaction. Convenient and high-throughput. Homogeneous "mix-incubate-measure"…

  • For quantitative determination of glutamine and evaluation of drug effects on glutamine metabolism. Linear detection range 0.023 - 2 mM glutamine in 96-well plate assay. Convenient room temperature. No 37°C heater is needed. Can be readily automated to process thousands of samples…

  • For quantitative enzymatic determination of urea. Fast and sensitive. Linear detection range (20 μL sample): 50 to 1000 μM urea in 96-well plate assay. The procedure involves adding a single working reagent, and reading the absorbance after 30 minutes. Room temperature assay. No…

  • HTS for inhibitor screening and evaluation of monoamine oxidase inhibitors. Convenient, homogeneous "Mix-incubate-measure" type assay. No wash and reagent transfer steps are involved. Can be readily automated for processing tens of thousands of samples per day. Method: FL530/585nm

  • For quantitative determination of phosphate and evaluation of drug effects on phosphate metabolism. Linear detection range 0.3 - 50 μM (0.0028 - 0.47 mg/dL) phosphate in 96-well plate assay. Can readily automated for processing thousands of samples per day. Method: OD620 nm. …

  • QuantiFluo™ HRP Reagent

    BioAssay Systems

    Stabilized 10-Acetyl-3,7-dihydroxyphenoxazine (also called Ampliflu Red) liquid substrate reagent for detecting horseradish peroxidase HRP activity, e.g. in ELISA. This reagent produces a highly fluorescent (530/590nm), pink-colored product upon reaction with a peroxidase. The fluorescent product…

  • For quantitative determination of galactose and its metabolism. Linear detection range 10 to 1000 μM galactose for colorimetric assays and 10 to 100 μM for fluorimetric assays. Method: OD570 nm, or FL530/585 nm. Samples: Serum, plasma, urine, saliva, milk, culture medium, food,…

  • For quantitative determination of lactose and evaluation of drug effects on lactose metabolism. Linear detection range 17 to 2000 μM lactose for colorimetric assays and 6 to 100 μM for fluorimetric assays. Method: OD570 nm, or FL530/585 nm. Samples: Biological (e.g. milk), food…

  • For quantitative determination of D-mannitol in biological, food, beverage and agriculture samples. Linear detection range 0.007 to 3 mM mannitol. Convenient room temperature assay. No 37°C heater is needed. Can be readily automated to test thousands of samples per day. Method:…

  • For quantitative determination of glucose oxidase activity and evaluation of drug effects on its metabolism. Linear detection range 0.02 to 10 U/L glucose oxidase for colorimetric assays and 0.002 to 1.5 U/L for fluorimetric assays. Homogeneous high-throughput assay. Method: OD570 nm,…

Compare Tool

Select up to 3 products

Please Log In