Agilent Technologies

UV-Vis Standards And Reagents

Not yet rated

In recent years, quality requirements as outlined by ISO 9000, GLP, GMP and NAMAS have assumed increasing importance. As a consequence, the recommendations of pharmacopoeias have become more influential in the pharmaceutical industry. Formal performance verification of UV-Visible spectrophotometers is now essential, but because of the non-availability of appropriate and/or easy-to-use standards, it has been done in ways which do not fully meet regulatory requirements or it has been very time consuming.

Agilent Technologies has made performance verification of the Agilent 8453 spectrophotometer much easier by making available sets of liquid standards in snap-open ampoules.

The standards can be used with standard open-topped cuvettes, but to reduce the time required and to minimize errors due to cross-contamination from standard to standard, Agilent recommends the use of flow cells for the verification. A hardware kit is available which includes all the items necessary. For reasons of safety in shipment the standards are packaged in two kits.

These are checkout samples only (not certified)

Agilent Technologies products are intended for sale/shipment within the US only. International customers should contact their local Agilent Technologies distributor to place orders for Agilent Technologies products.

StandardPurpose
60.06 mg/L potassium dichromate 0.01 N sulphuric acidPhotometric accuracy at 235, 257, 313 and 350 nm
0.01 N sulphuric acidBlank for photometric accuracy test
12 g/L potassium chloride in waterStray light at 200 nm
10 g/L sodium iodide in waterStray light at 220 nm
50 g/L sodium nitrite in waterStray light at 340 nm
0.02% v/v toluene in hexaneResolution (ratio of the absorbance maximum at 269 nm to the absorbance minimum at 266 nm)
HexaneBlank for resolution test
Note: HPLC grade water is recommended as blank for the stray light tests.
StandardPurpose
40 g/L holmium oxide in 10% v/v perchloric acidWavelength accuracy in UV and visible ranges
10% v/v perchloric acidBlank for wavelength accuracy

Please Enter Your Order Info

Filter by:

  • Clear Filters
Product Detail
Thomas No.
2714H15
Mfr. No.
5042-6476
Description
Caffeine OQ / PV Sample For Dissolution Test, 150 Mg / L Caffeine In Water, 500 ml

Domestic Only (Domestic Only)

list price/quantitytotal
$0.00
Thomas No.
2714J68
Mfr. No.
5063-6503
Description
OQ / PV Chemical Standards Kit I Contains: 10 Ampoules 10 ml Each Of 2 Dichromate, 2 Sulfuric Acid, 1 Sodiumnitrite, 1 Sodium Iodide, 1 Potassium Chloride, 1 Toulene In Hexane, 2 Hexane

Domestic Only (Domestic Only)

list price/quantitytotal
$0.00
Thomas No.
2714J80
Mfr. No.
5063-6521
Description
OQ / PV Chemical Standards Kit II (For Wavelength Accuracy)Contains Two Ampoules 10 ml Each Of 2 Perchloric Acid, 1 Holmium Oxide Inperchloric Acid

Domestic Only (Domestic Only)

list price/quantitytotal
$0.00
Thomas No.
2714J81
Mfr. No.
5063-6522
Description
Tubing Kit For UV-Vis OQ / PV Testcontains Tubings, Fittings And Adapter To Flush Flow Cell

Domestic Only (Domestic Only)

list price/quantitytotal
$0.00
Thomas No.
2714J82
Mfr. No.
5063-6523
Description
OQ / PV Hardware Kitcontains 2 Flow Cells, Cell Passivating Fluid, Tubing Kit, Mct Adjustment Tool, Temperature Sensor Support, Syringes And OQ / PV Manual

Domestic Only (Domestic Only)

list price/quantitytotal
$0.00
Thomas No.
2714J83
Mfr. No.
5063-6524
Description
Test Sample For UV-Vis (Caffeine Solution, 10 ug / ml In Water)

Domestic Only (Domestic Only)

list price/quantitytotal
$0.00
Thomas No.
2715F18
Mfr. No.
89075-23800
Description
Multicell Transport Adjustment Tool