• PRODUCT AVAILABILITY: Did you know you can view a product's availability right on the product page? Simply enter the quantity you want to purchase and the current availability will appear below the item.

  • Product is restricted and can only be purchased by customers with a web profile linked to a Thomas Business Account - Click here to login or create your web profile. If you do not have a Thomas Business Account, please Contact Us and someone will respond with details on how to apply for a business account with us.

Ricca Chemical

Manganous Sulfate Solution

Not yet rated

Formula: MnSO4•H2O

Formula Weight: 169.02

Description: 364 g/L

Model

DNF301

DNF401/411

DNF601/611

DNF811

DNF911

Circulation method

Forced convection + Natural convection

Forced convection

External temp. range

5~35°C

Temperature set range

0~130°C (Wind velocity: 0), 0~270°C (Wind velocity: 1~10)

0~270°C (Wind velocity: 1~10)

Temperature control range

RT +25~120°C (Wind velocity: 0), RT +15~260°C (Wind velocity: 1~10)

RT +15~260°C (Wind velocity: 1~10)

Temp. control

accuracy *1

Forced convection

±0.3°C (at 260°C)

Natural convection

±0.5°C (at 120°C)

±0.3°C (at 120°C)

Not applicable

Temp.

fluctuation *1

Forced convection

±0.5°C (at 260°C)

Natural convection

±1.0°C (at 120°C)

±0.8°C (at 120°C)

±0.6°C (at 120°C)

Not applicable

Temp. distribution

precision *1

Forced convection

±2.5°C (at 260°C)

Natural convection

±5°C (at 120°C)

±3°C (at 120°C)

Not applicable

Temp. gradient *1

Forced convection

5°C (at 260°C)

7°C (at 260°C)

8°C (at 260°C)

12°C (at 260°C)

6°C (at 260°C)

Natural convection

15°C (at 120°C)

13°C (at 120°C)

Not applicable

Temp. rise

time *1

Forced convection

~70min.

~105min.

~100min.

~60min.

~100min.

Natural convection

~20min.

~25min.

Not applicable

Chamber / Exterior / Insulation

Stainless steel / Cold rolled steel paneling, chemical-proof baked-on finish / Glass wool

Door

Single swing (left side)

Double doors (opening from center)

Heater (stainless steel tube)

0.8kW

0.6kWx2

0.83kWx2

1.35kWx2

1.65kWx2

Wind velocity adjusting system

10 steps (600~1500rpm) + Wind velocity (0)

10 steps (600~1500rpm)

Damper

Circulation-Ventilation Manual switching: Interlocked intake and exhaust system

(Complete exhaust applicable / Unable to reach 260°C with damper fully open)

Cable port

Inner diameter: 33mm×1 (right side)

Exhaust port

Outer diameter: 50mm×1 (back side)

Outer diameter: 50mm×2

(back side)

Inlet port

Inner diameter: 33mm×1 (right side)

Inner diameter: 33mm×2

(both side)

Controller

Model V type

Temperature control / setting system

PID Z control / Digital setting with ?/? keys

Temperature display system

Temperature reading display: green 4-digit digital LED / Temperature setting display: orange 5-digit digital LED

Other indications

LED indicates temperature patterns for heating/stabilizing/cooling

Timer

Fixed temperature operation, Program operation (maximum 99 steps or 99 patterns, with repeat operation function), Timer or clock operation function (Fixed temperature operation w/ auto start/auto stop/quick auto stop, program operation auto start)

Additional functions

Variable Air Flow Function, Power-on Time and Operation Time Accumulation Monitor (up to 65,535 hours); Calibration Offset; Monitoring Display for Accumulated Power Consumption, Total CO2 Emissions, and Heater Operation Output; Power Recovery Mode; Setting Data Backup and Recovery

Temperature sensor

K type Thermocouple double sensor (for temperature control and independent overheat prevention device)

Heater control

Triac with Zero-cross Control

Control board

Self-diagnostic Functions (Detection for Temp. Sensor Failure, TRIAC Short Circuit, Automatic overheating prevention, Heater Line Disconnect, Main Relay Contact Damage ), Earth leakage breaker, Fan Motor Failure, Key Lock Function, Independent overheating prevention device

Earth leakage breaker

Leak Current/Short Circuit/Over-current Protection, Rated Current Sensitivity 30mA

Door switch

Door open: fan motor and heater circuit OFF, Door close: fan motor and heater circuit ON

Internal dimensions (W×D×H mm)*2

300×300×300

450×450×450

600×500×500

600×500×1000

1090×500×1000

External dimensions (W×D×H mm)*2

430×495×740

580×645×890

730×695×940

730×695×1685

1220×695×1685

Capacity

27L

90L

150L

300L

540L

Weight

~50kg

~75kg

~90kg

~135kg

~210kg

Number of shelf bracket step / pitch

6 steps/30mm

11 steps/30mm

13 steps/30mm

29 steps/30mm

Withstand load of shelf

15kg/shelf

Power supply V±10% 50/60Hz Single phase

AC115V, 7.5A

AC115/220V 11A/6A

AC115/220V 15A/8A

AC220V 15.5A

AC220V 18.5A

Shelf plate / bracket

2 pcs. / 4 pcs.

4 pcs. / 8 pcs.

8 pcs. / 16 pcs.

Please Enter Your Order Info

Filter by:

  • Clear Filters
Product Detail
Thomas No.
C478D50
Mfr. No.
4620-16
Pkg. Size
500 mL
Description
Manganous Sulfate, APHA Solution, 36%, For Dissolved Oxygen 500ml
Pkg. Type
Bottle, Poly
list price/quantitytotal
$0.00
Thomas No.
C478D53
Mfr. No.
4620-32
Pkg. Size
1 L
Description
Manganous Sulfate, APHA Solution, 36%, For Dissolved Oxygen 1L
Pkg. Type
Bottle, Poly
list price/quantitytotal
$0.00
Thomas No.
C478D56
Mfr. No.
4620-1
Pkg. Size
4 L
Description
Manganous Sulfate, APHA Solution, 36%, For Dissolved Oxygen 4L
Pkg. Type
Bottle, Poly
list price/quantitytotal
$0.00
$0.00 (0 Items)
Product is restricted and can only be purchased by customers with a web profile linked to a Thomas Business Account - Click here to login or create your web profile. If you do not have a Thomas Business Account, please Contact Us and someone will respond with details on how to apply for a business account with us.

Write A Review