Welcome, How May We Help You? (Log In Register)

NARROW RESULTS BY

Category

Manufacturer

Page  of 1
Sort
View
Show
  • SimpleVIS™ Portable Viscometer

    Cannon Instrument
    kinematic viscosity, no need to correlate data Modified cross-arm style tube, works with both transparent and opaque oils Reliable, only 2 moving parts Easy-to-use graphical touch screen Small sample volume: <0.5 mL Rapid automated analysis: <3 minutes The Cannon SimpleVIS™ Portable Viscometer
  • Cannon-Fenske Series Viscometers

    Cannon Instrument
    …outside of the box and on the viscometer. Additional sizes are available on special order. Holder not supplied. See Thomas numbers 9726M50 and M53 for holders. Cannon Fenske Opaque, CFOU (Uncalibrated) and CFOC (Calibrated) Viscometers Reverse-Flow Type; Measures kinematic viscosity of dark Newtonian…
  • CT-500 And CT-518 Constant Temperature Baths

    Cannon Instrument
    …depth: 457 mm (18") Cylindrical glass vessel is deeper than glass vessel of CT-500, allowing the use of longer viscometers such as the Cannon- Ubbelohde Four-Bulb Shear Dilution Viscometer (ten-fold dilution type). Otherwise identical to Model CT-500. Power requirements: 9726A17 is 115 to 120 V, 50/60…
  • Cannon-Ubbelohde, CUU And CUC Series Viscometers

    Cannon Instrument
    Uncalibrated and Calibrated Viscometers Suspended level viscometer for measurement of kinematic viscosity of transparent Newtonian liquids Also used for evaluating jet fuels and hydraulic fluids Meets ASTM D 445 and D 446, as well as ISO 3104 and 3105 requirements Suitable for use at temperatures…
  • BS/U Tube Viscometers

    Cannon Instrument
    Calibrated viscometers For measuring kinematic viscosity of transparent Newtonian liquids Meets ASTM D 445 and ISO 3104 Specifications conform to ASTM D 446 and ISO 3105. Precision: ±0.2%. Minimum sample volume: 7 mL in sizes A to C; 12 mL in sizes D to F ; 23 mL in sizes G and H. Requires liquid…
  • BS/IP/SL(S) Viscometers

    Cannon Instrument
    Calibrated viscometers For measuring kinematic viscosity of transparent Newtonian liquids Meets ASTM D 445 and ISO 3104 Specifications conform to ASTM D 446 and ISO 3105. Precision: ±0.2%. Minimum sample volume:10 mL. Requires liquid bath depth of 230 mm (9”). Includes certificate of calibration…
  • BS/IP/MSL Miniature Suspended Level Viscometers

    Cannon Instrument
    Calibrated viscometers For measuring kinematic viscosity of transparent Newtonian liquids Meets ASTM D 445 and ISO 3104 Specifications conform to ASTM D 446 and ISO 3105. Precision:±0.2%. Minimum sample volume:4 mL. Requires liquid bath of 305 mm (12”). Includes certificate of calibration and…
  • Bubble Viscometers

    BYK-Gardner
    Yields accurate kinematic viscosity data quickly and easily using the Alphabetical Comparison Method (upward speed of a trapped air bubble) Conforms to ASTM D 1131, D 1545 and D 1725 Standard tubes easily identified by large letters Quick and easy cleaning Viscosity of the liquid sealed in each…
  • VISDISK for Windows

    Cannon Instrument
    …Chart Blending Method Kinematic viscosity calculations- allows the estimation of kinematic viscosity (cSt), viscosity (cP) and density of an oil at any temperature Determination of Viscosity Index- calculates the Viscosity Index after entering the kinematic viscosity at any two temperatures…
  • Cannon-Ubbelohde UBU And UBC Series

    Cannon Instrument
    Uncalibrated and Calibrated Viscometers Measure kinematic viscosity of transparent Newtonian liquids by suspended level principle Meets ASTM D 445 and D 446 and ISO 3104 and 3105 requirements. Precision: ?0.2% Similar to Cannon-Ubbelohde but less rugged in design. Includes instruction…
  • BS/U/M Miniature U-Tube

    Cannon Instrument
    Calibrated viscometers For measuring kinematic viscosity of transparent Newtonian liquids Meets ASTM D 445 and ISO 3104 Precision: ±0.2% Specifications conform to ASTM D 446 and ISO 3105. Minimum sample volume: 2 mL. Requires liquid bath depth of 230 mm (9"). Includes certificate of calibration…
  • CT-1000 Constant Temperature Baths

    Cannon Instrument
    …holes 51 mm (2") in diameter for insertion of viscometers. Each unit maintains accurate temperature control of 0.01°C within the range of 20°C to 100°C and 0.03°C above 100°C, providing the temperature sensitivity required by ASTM D 445 for kinematic viscosity measurements. Two electric heating elements…

Please Log In

Don't have an Account? Create one now.