Boekel OpenSourceBio

  • CT-500 And CT-518 Constant Temperature Baths

    Cannon Instrument
    …depth: 457 mm (18") Cylindrical glass vessel is deeper than glass vessel of CT-500, allowing the use of longer viscometers such as the Cannon- Ubbelohde Four-Bulb Shear Dilution Viscometer (ten-fold dilution type). Otherwise identical to Model CT-500. Power requirements: 9726A17 is 115 to 120 V, 50/60…
  • Cannon-Ubbelohde UBU And UBC Series

    Cannon Instrument
    Uncalibrated and Calibrated Viscometers Measure kinematic viscosity of transparent Newtonian liquids by suspended level principle Meets ASTM D 445 and D 446 and ISO 3104 and 3105 requirements. Precision: ?0.2% Similar to Cannon-Ubbelohde but less rugged in design. Includes instruction…
  • CT-1000 Constant Temperature Baths

    Cannon Instrument
    …holes 51 mm (2") in diameter for insertion of viscometers. Each unit maintains accurate temperature control of 0.01°C within the range of 20°C to 100°C and 0.03°C above 100°C, providing the temperature sensitivity required by ASTM D 445 for kinematic viscosity measurements. Two electric heating elements…
  • SimpleVIS™ Portable Viscometer

    Cannon Instrument
    kinematic viscosity, no need to correlate data Modified cross-arm style tube, works with both transparent and opaque oils Reliable, only 2 moving parts Easy-to-use graphical touch screen Small sample volume: <0.5 mL Rapid automated analysis: <3 minutes The Cannon SimpleVIS™ Portable Viscometer
  • Cannon-Fenske Series Viscometers

    Cannon Instrument
    …outside of the box and on the viscometer. Additional sizes are available on special order. Holder not supplied. See Thomas numbers 9726M50 and M53 for holders. Cannon Fenske Opaque, CFOU (Uncalibrated) and CFOC (Calibrated) Viscometers Reverse-Flow Type; Measures kinematic viscosity of dark Newtonian…
  • Zeitfuchs Cross-Arm Calibrated Viscometers

    Cannon Instrument
    …boxed. Serial number is printed on the outside of the box and on the viscometer. Certificate of calibration and instruction sheet provided. Holders not included; see Thomas numbers 9726M95 and M98. For measurement of kinematic viscosity of transparent and opaque Newtonian liquids Meets ASTM Standard…
  • Semi-Micro, Cannon CUSMC Series Viscometer

    Cannon Instrument
    Calibrated For measurement of kinematic viscosity of small samples of transparent Newtonian liquids Meets ASTM Standard D 445; specifications conform with ASTM Standard D 446 Viscometer constant is same at all temperatures Initial sample can be diluted to as much as 20 mL for intrinsic viscosity…
  • Viscometer Cleaning And Drying Apparatus

    Koehler
    Removes all traces of oil Air pressure drives solvent No electrical contact needed Unit is designed to wash the inside of glass kinematic viscometer tubes with a jet of solvent. At the touch of a button, the solvent stream is cut off and an air jet is directed into the tubes for drying. Cleaning…
  • Flow Cup Viscometers

    Fungilab
    …viscometers—made of anodized aluminium body with a stainless steel orifice—provide accurate kinematic viscosity data. They are ideal for the paints, inks, and varnishes industries. The measured kinematic viscosity is generally expressed in seconds (s) flow time when the fluid is flowing through an…
  • BS/IP/RF U-Tube Reversed Flow Viscometers

    Cannon Instrument
    Calibrated viscometers For measuring kinematic viscosity of opaque Newtonian liquids Meets ASTM D 445 and ISO 3104 Specifications conform to ASTM D 446 and ISO 3105. Precision: ?0.3%. Minimum sample volume: 7 mL. Requires liquid bath depth of 280 mm (11"). Includes certificate of calibration…
  • Cannon-Manning Semi-Micro, Cannon CMSMC Series Viscometers

    Cannon Instrument
    Calibrated Viscometers For measurement of kinematic viscosity of small samples of transparent Newtonian liquids, particularly petroleum products or lubricants Meets ASTM D 445 requirements Precision: ?0.2% Specifications conform with ASTM Standard D 446. Minimum sample volume: 1…
  • BS/U Tube Viscometers

    Cannon Instrument
    Calibrated viscometers For measuring kinematic viscosity of transparent Newtonian liquids Meets ASTM D 445 and ISO 3104 Specifications conform to ASTM D 446 and ISO 3105. Precision: ±0.2%. Minimum sample volume: 7 mL in sizes A to C; 12 mL in sizes D to F ; 23 mL in sizes G and H. Requires liquid…
  • BS/IP/SL(S) Viscometers

    Cannon Instrument
    Calibrated viscometers For measuring kinematic viscosity of transparent Newtonian liquids Meets ASTM D 445 and ISO 3104 Specifications conform to ASTM D 446 and ISO 3105. Precision: ±0.2%. Minimum sample volume:10 mL. Requires liquid bath depth of 230 mm (9”). Includes certificate of calibration…
  • BS/IP/MSL Miniature Suspended Level Viscometers

    Cannon Instrument
    Calibrated viscometers For measuring kinematic viscosity of transparent Newtonian liquids Meets ASTM D 445 and ISO 3104 Specifications conform to ASTM D 446 and ISO 3105. Precision:±0.2%. Minimum sample volume:4 mL. Requires liquid bath of 305 mm (12”). Includes certificate of calibration and…
  • Bubble Viscometers

    BYK-Gardner
    Yields accurate kinematic viscosity data quickly and easily using the Alphabetical Comparison Method (upward speed of a trapped air bubble) Conforms to ASTM D 1131, D 1545 and D 1725 Standard tubes easily identified by large letters Quick and easy cleaning Viscosity of the liquid sealed in each…
  • VISDISK for Windows

    Cannon Instrument
    …Chart Blending Method Kinematic viscosity calculations- allows the estimation of kinematic viscosity (cSt), viscosity (cP) and density of an oil at any temperature Determination of Viscosity Index- calculates the Viscosity Index after entering the kinematic viscosity at any two temperatures…
  • Ubbelohde Capillary Viscometers

    Fungilab
    …D445-446, ASTM D2515, ISO 3104-3105 and UNE 400313) UBBELOHDE DIN (DIN 51562 Part 1, ISO 3105 and UNE 400313) Ubbelohde Viscometers are used to determine kinematic viscosity of transparent Newtonian liquids. Sample volume: aprox. 15 ml. Precision: ±0.2%.
  • BS/U-Tube Capillary Viscometers

    Fungilab
    BS/U Tube glass capillary viscometers are ideal for measuring the kinematic viscosity of transparent Newtonian fluids within a range of 0.9-10,000 cSt. Includes a calibration certificate with a Constant values at 40°C and 100°C and a precision of ±0.2%. Viscometers conform to ASTM D445, D446, ISO…
  • BS/U/M Miniature U-Tube

    Cannon Instrument
    Calibrated viscometers For measuring kinematic viscosity of transparent Newtonian liquids Meets ASTM D 445 and ISO 3104 Precision: ±0.2% Specifications conform to ASTM D 446 and ISO 3105. Minimum sample volume: 2 mL. Requires liquid bath depth of 230 mm (9"). Includes certificate of calibration…
  • CT-600 Constant Temperature Bath

    Cannon Instrument
    Ideal for kinematic viscosity determinations between 10°C and 30°C Built-in thermoelectric cooling provides “rock-solid” temperature control at ambient and below Meets ASTM D 445 precision specifications from 10°C to 100°C The Cannon CT-600 has many of the engineering and control features…