Cannon Instrument

Compare Tool

Select up to 3 products

All Products

Cannon Instrument

1 - 32 of 67
Sort
View
Show
  • General Purpose Viscosity Standards

    Cannon Instrument

    Based on NIST value of 1.0016 centipoise for water at 20C; conforms to ASTM Standards D 445, D 88 and D 2161; traceable to NIST Approximate viscosities at varying temperatures in centistokes and centipoises are given in Table 1; each standard is furnished with actual viscosity and density…

  • Cannon-Fenske Series Viscometers

    Cannon Instrument

    Cannon Fenske Routine, CFRU (Uncalibrated) & CFRC (Calibrated) Viscometers For measurement of kinematic viscosity of transparent Newtonian liquids, particularly petroleum products or lubricants Meets ASTM D 445 and ISO 3104 requirements Specifications conform to ASTM D 446 and ISO 3105 …

  • Cannon-Ubbelohde UBU And UBC Series

    Cannon Instrument

    Uncalibrated and Calibrated Viscometers Measure kinematic viscosity of transparent Newtonian liquids by suspended level principle Meets ASTM D 445 and D 446 and ISO 3104 and 3105 requirements. Precision: ±0.2% Similar to Cannon-Ubbelohde but less rugged in design.…

  • Paint Viscosity Standards

    Cannon Instrument

    For Thomas®-Stormer® Viscometers Based on NIST value of 1.0016 centipoise for water at 20°C. Traceable to NIST. Approximate viscosity in centipoise and Krebs unit values at 25°C are given in table below. Actual value are furnished with each standard. Supplied in a one pint bottle.

  • Cold Cranking Simulator Viscosity Standards

    Cannon Instrument

    Conform to SAE specification J300 and ASTM D 5293 Viscosities based on NIST value of 1.0016 centipoise for water at 20°C Traceable to NIST Supplied in one pint bottles

  • General Purpose Low Temperature Viscosity Standards

    Cannon Instrument

    CANNON Low Temperature Viscosity Standards verify viscometer performance at sub-zero temperatures. These standards are applicable to SAE Specification J300 as well as a variety of ASTM Methods including: ASTM D2983, Low-Temperature Viscosity of Lubricants Measured by Brookfi eld…

  • Cannon-Ubbelohde, CUU And CUC Series Viscometers

    Cannon Instrument

    Uncalibrated and Calibrated Viscometers Suspended level viscometer for measurement of kinematic viscosity of transparent Newtonian liquids Also used for evaluating jet fuels and hydraulic fluids Meets ASTM D 445 and D 446, as well as ISO 3104 and 3105 requirements Suitable for use at…

  • Calibrated ASTM Thermometers

    Cannon Instrument

    Kinematic Viscosity, Celsius Mercury-in-glass thermometers conforming to ASTM Standard E1 With a Factory Calibration Certificate traceable to NIST Designed for total immersion Length approximately 305 mm, stem diameter 6.5 to 8 mm Calibrated at two temperatures on main scale and at ice point…

  • CT-1000 Constant Temperature Baths

    Cannon Instrument

    Wide temperature range 20°C to 150°C Easy temperature setting Insulated for precise solid-state temperature control Multiple safety features Ideal for temperature control of other instruments which must be viewed while immersed in a constant temperature bath. The top…

  • Flash Point Reference Materials

    Cannon Instrument

    CANNON Instrument Company can now provide Flash Point Reference Materials for calibrating Flash Point Testers. A total of six different standards are available for the following ASTM methods: ASTM D 56, ASTM D 92, and ASTM D 93. The data provided for each standard includes the average flash point…

  • High Viscosity Standards

    Cannon Instrument

    For determining viscosities in asphalt and polymers (see ASTM D 2170 and D 2171) Traceable NIST For Kinematic Viscosity Values (cSt), please contact Thomas Scientific

  • SimpleVIS™ Portable Viscometer

    Cannon Instrument

    Quick and reliable automation Direct kinematic viscosity, no need to correlate data Modified cross-arm style tube, works with both transparent and opaque oils Reliable, only 2 moving parts Easy-to-use graphical touch screen Small sample volume: <0.5 mL Rapid automated analysis: <3…

  • CT-2000 Constant Temperature Bath

    Cannon Instrument

    Microprocessor controlled temperature regulation from 10 to 150°C Conforms to ASTM D 445 Built-in platinum resistance thermometer On-screen temperature monitoring RS 232 and RS 485 communication ports A keypad permits temperature selection to two decimal…

  • Bath Oil, 6-Gallon Container

    Cannon Instrument

    Contains an oxidation inhibitor which reduces tendency to darken at higher temperatures For use below 135°C (275°F) For higher temperature requirements, see Thomas number 6428R25.

  • Removable Viscometer Holders

    Cannon Instrument

    All Cannon viscometer holders are designed to fit holes 51 mm (2 in.) in diameter. Rubber holders are made of neoprene rubber.  Plastic holders hold the viscometer firmly with a spring clip.  Metal holders are constructed of chrome-plated machined brass.  A handle permits…

  • Cold-Cranking Simulator Standards

    Cannon Instrument

    CANNON CL Standards provide certified dynamic viscosity data (in cP or mPa·s) at temperatures from –5°C to –35°C. These standards are used to calibrate the CANNON Cold-Cranking Simulator (CCS) oil testing (see ASTM D 5293 and SAE Specification J300).

  • Asphalt Institute Vacuum, Cannon Aivc Series Viscometers

    Cannon Instrument

    Calibrated viscometers For measuring viscosity of highly viscous materials such as asphalt cement at 60°C (140°F) Meets ASTM D 2171 Applicable to materials with viscosity range of 42 to 5,800,000 poises With graduated capillary to extend viscosity range of viscometer Minimum sample size: 3…

  • Zeitfuchs Cross-Arm Calibrated Viscometers

    Cannon Instrument

    Cannon ZCAC Series For measurement of kinematic viscosity of transparent and opaque Newtonian liquids Meets ASTM Standard D 445 specifications; also conform to ASTM Standard D 446 Precision: ±0.3% Also used to measure kinematic viscosity of cut-back asphalts and road oils at 140°F (60°C) and…

  • Silicone Viscosity Standards

    Cannon Instrument

    For calibration of rotational viscometers Viscosity certified at 20, 23, 24, 25, 26 and 27°C Calibrated to a precision of ±0.2% NIST traceable Standards are based on the National Institute of Standards and Technology (NIST) value of 1.0016 mPa-s (centipoise) for…

  • Solid Rubber Micro Stopper

    Cannon Instrument

    Tapered from 6 mm top diameter to 2 mm bottom diameter, these solid rubber micro stoppers measure 20 mm long. Micro stoppers are for use with Cannon-Fenske Qpaque Viscometer and Cannon Cold-Cranking Simulator.

  • Flash Point Tester 115V

    Cannon Instrument

    Asphalt Cleveland Open Cup Flash Point Tester Model aco-8 and aco-8as asphalt versions are the automated Cleveland Open Cup flash point tester from Tanaka. Based on 45 years experience of manufacturing the automated flash point testers, innovative 8th generation series has been released. The…

  • Cannon-Manning Vacuum, Cannon CMVC Series Viscometers

    Cannon Instrument

    Calibrated viscometers For measurement of viscosity of highly viscous materials such as asphalt cement at 140°F Meets ASTM Standard D 2171 Applicable to materials with viscosity range of 0.036 to 80,000 poise. Vacuum of 300 mm Hg is applied to small arm with timing bulbs; two…

  • BS/U/M Miniature U-Tube

    Cannon Instrument

    Calibrated viscometers For measuring kinematic viscosity of transparent Newtonian liquids Meets ASTM D 445 and ISO 3104 Precision: ±0.2% Specifications conform to ASTM D 446 and ISO 3105. Minimum sample volume: 2 mL. Requires liquid bath depth of 230 mm (9"). Includes certificate of…

  • BS/IP/RF U-Tube Reversed Flow Viscometers

    Cannon Instrument

    Calibrated viscometers For measuring kinematic viscosity of opaque Newtonian liquids Meets ASTM D 445 and ISO 3104 Specifications conform to ASTM D 446 and ISO 3105. Precision: ±0.3%. Minimum sample volume: 7 mL. Requires liquid bath depth of 280 mm (11"). Includes…

  • CT-500 And CT-518 Constant Temperature Baths

    Cannon Instrument

    CT-500 Temperature range 20° to 100°C Easy temperature setting Precise solid state temperature control within 0.01°C Multiple safety features The top cover contains seven round holes 51 mm (2") in diameter. Each unit maintains accurate temperature control of 0.01°C within the range of…

  • Flash Point Reference

    Cannon Instrument

    CANNON Instrument Company can now provide Flash Point Reference Materials for calibrating Flash Point Testers. A total of six different standards are available for the following ASTM methods: ASTM D 56, ASTM D 92, and ASTM D 93. The data provided for each standard includes the average flash point…

  • BS/U Tube Viscometers

    Cannon Instrument

    Calibrated viscometers For measuring kinematic viscosity of transparent Newtonian liquids Meets ASTM D 445 and ISO 3104 Specifications conform to ASTM D 446 and ISO 3105. Precision: ±0.2%. Minimum sample volume: 7 mL in sizes A to C; 12 mL in sizes D to F ; 23 mL in sizes G and H. Requires…

  • Pressure / Vacuum Pump, 120V, 60Hz

    Cannon Instrument

    Inexpensive, compact source of low-level pressure and vacuum Fused circuit and grounded plug ensure safe operation Multiple fittings kit and polyurethane tubing are provided Oilless diaphragm pump operates quietly to produce a continuous pressure of 35 psi or an adjustable,…

  • Ink and Paint Viscosity Standards

    Cannon Instrument

    For ink and paint viscometers For use with Zahn, Shell and Ford viscometer cups. Based on NIST value of 1.0016 centipoise for water at 20°C. Traceable to NIST. Approximate kinematic viscosity and drain times for the various cups at 25°C are given in table. Actual values are furnished…

  • BS/IP/SL Suspended Level Viscometer

    Cannon Instrument

    Calibrated viscometers For measuring kinematic viscosity of transparent Newtonian liquids Meets ASTM D 445 and ISO 3104 Specifications conform to ASTM D 446 and ISO 3105 Precision: ±0.2% Minimum sample volume: 11 mL. Requires liquid bath depth of 250 mm (10”).…

  • Viscosity Standard, -20 and -25°C for CMRV, 500 ml

    Cannon Instrument

    For preceding the borderline pumping temperature of engine oil in accordance of ASTM Standards D 3829 and D 4684 Viscosity of 30,000 centipoise at -20°C based on NIST value of 1.0016 centipoise for water at 20°C; traceable to NIST

  • MPC-102S Mini Pour/Cloud Point, 115V

    Cannon Instrument

Compare Tool

Select up to 3 products

Please Log In