Water Quality

Compare Tool

Select up to 3 products

All Products

Hach Water Quality Water Quality Test Kits

1 - 32 of 56
Sort
View
Show
  • Chlorine Single Parameter Kits

    Hach

    Reagents Chlorine is the most widely used disinfectant for drinking water and is also important for sanitizing swimming pools, cooling towers, other industrial equipment and treatment of wastewater. Its measurement and control are vital for both safety and economic reasons. Many Hach chlorine…

  • Bart Tester

    Hach

    BART Test, Iron-Related Bacteria BART Test, Sulfate-Reducing Bacteria BART Test, Slime-forming Bacteria BART biodetectors are excellent diagnostic tools to help identify the presence of process disruptors, such as bacteria creating slime layers and limiting disinfection. Find out if you…

  • PhosVer® 3 Phosphate Reagent Powder Pillows

    Hach

    For determination of reactive (ortho) phosphate (phosphorus) by the PhosVer® 3 ascorbic acid method.  USEPA accepted for reporting for wastewater analysis using Hach Method 8048, Phosphorus, Reactive.  Also used in acid-hydrolyzable and total phosphorus determination, after…

  • Ammonia TNTplus, HR

    Hach

    For determination of Ammonia Nitrogen by the Salicylate Method, using TNTplus vials. Hach Method 10205. High Range: 2 - 47 mg/L NH3-N. ?25 tests/package. Reduce Errors with Bar-coded Vials No Reagent Blank Necessary Innovative Vial and Reagent Delivery Helpful package design

  • Nitrogen, Nitrate Test Kits

    Hach

    Normally found in water and soil as ammonia (NH3), nitrate (NO3), and nitrite (NO2), nitrogen is an indispensable part of the life cycle. However, concentrations above certain levels can present problems. Thomas No. 3241S80 Utilizing the simple color…

  • Water Hardness Single Parameter Test Kit

    Hach

    Water hardness is caused almost entirely by calcium and magnesium ions. Other di- and trizalent metals have a similar effect, but usually are not present in high enough concentration in potable waters to cause problems. Hardness increases soap consumption in laundries and causes scale in boilers. …

  • Magnesium Chloride And Potassium Dihydrogen Phosphate Water Concentrate Pillows5

    Hach

    Buffered Dilution Water Pillows, pk/25 (magnesium chloride and potassium dihydrogen phosphate, makes 25 L dilution water; 1 liter per pillow.)

  • Model CN-67 Chlorine (Free & Total) and pH Test Kit

    Hach

    Control of chlorine and pH in pools and spas to maintain safe bathing conditions and to protect against system corrosion. Supplied with color discs and comparator for monitoring chlorine and pH, the Free & Total Chlorine and pH Test Kit provides more accuracy than test kits using color cubes. …

  • Hardness, Iron And pH Test Kits

    Hach

    Includes color disc and color comparator for colorimetric comparison of iron and pH, as well as a drop-count titrator for hardness determination. Test kit produces a wide range of pH tests. Combines frequently measured parameters in one rugged kit Uses color disc and drop count titration…

  • Alkalinity Single Parameter Test Kits

    Hach

    Alkalinity is caused by the presence of carbonates, bicarbonates, hydroxides, and other dissolved salts in water. Alkalinity control is important to food and beverage processors, boiler operators, and aquatic biologists. Model AL-AP single parameter alkalinity test kit has a range of 0.4-8 gpg…

  • Sulfite Test Kits

    Hach

    Because sulfite readily oxidizes to sulfate, it normally is not present in natural waters. It is used in paper mills for bleaching pulp and in boiler water as an oxygen scavenger.

  • Test Kit, Po-19 Phosphate High

    Hach

    Phosphorus occurs in natural waters as one of the forms of phosphates: ortho- or reactive phosphate, meta- or poly- (condensed) phosphate, and organic phosphate. Phosphates enter water supplies from soil runoff, cleaning operations, water treatment, boiler blowdown, and sewage. Although…

  • Aluminum TNTplus, Chromazurol S

    Hach

    Reduce Errors with Bar-coded Vials and RFID A unique barcode label on each Hach TNTplus Vial Chemistry is automatically read by the spectrophotometer when used with Hach’s DR 6000™ UV-VIS Spectrophotometer or DR 3900™ Benchtop Spectrophotometer to identify the appropriate…

  • Ammonia TNTplus, ULR

    Hach

    For determination of Ammonia Nitrogen by the Salicylate Method, using TNTplus vials. Hach Method 10205. Ultra Low Range: 0.015 - 2.00 mg/L NH3-N. 25 tests/package Reduce Errors with Bar-coded Vials No Reagent Blank Necessary Innovative Vial and Reagent Delivery Helpful package design

  • Chemical Oxygen Demand (COD), Mercury-Free, TNTplus, HR

    Hach

    For determination of Chemical Oxygen Demand (COD) by the Mercury-Free Reactor Digestion Method, using TNTplus™ vials. Hach Method 10236 Range: 25-1000 mg/L COD. Reduce Errors with Bar-coded Vials No Reagent Blank Necessary Innovative Vial and Reagent Delivery Helpful package design

  • Phosphorus TNTplus, LR Reactive and Total

    Hach

    For determination of Reactive (ortho) and Total Phosphorus (phosphate) by the Ascorbic Acid method, using TNTplus vials. Hach Methods 10209 (reactive) and 10210 (total). Low Range: 0.05-1.50 mg/L PO4-P (0.15-4.50 mg/L PO4). 25 tests/package. Reduce Errors with Bar-coded Vials No Reagent…

  • Chloride Single Parameter Test Kits

    Hach

    Found in nearly all natural waters, chloride affects human taste above 250 mg/L. High levels inhibit plant growth, and many industrial processes need to limit chloride concentration. Test kits use either silver or mercuric nitrate titrant. The model CD-DT, a multi-range kit, is supplied with the…

  • Lauryl Tryptose Broth With Mug

    Hach

    Selectivity: Total Coliform Bacteria and Escherichia coli 1 Year shelf life at room temperature

  • Nitrite TNTplus, LR

    Hach

    For determination of Nitrite Nitrogen by the Diazotization method, using TNTplus vials. Hach Method 10207. Low Range: 0.015-0.600 mg/L NO2-N, (0.05-2.00 mg/L NO2). 25 tests/package Reduce Errors with Bar-coded Vials No Reagent Blank Necessary Innovative Vial and Reagent Delivery …

  • Phosphorus TNTplus, HR

    Hach

    For determination of Reactive (ortho) and Total Phosphorus (phosphate) by the Ascorbic Acid method, using TNTplus vials. Hach Methods 10209 (reactive) and 10210 (total). High Range: 0.5-5.0 mg/L PO4-P (1.5-15.0 mg/L PO4). 25 tests/package Reduce Errors with Bar-coded Vials No Reagent…

  • Model PBC-DT Professional Boiler Treatment/Boiler Feed and Cooling Water Test…

    Hach

    In addition to all of the test offered in Model BT-DT (2350600) this test kit provides testing capability for iron, silica, chlorine, nitrite, and total dissolved solids (TDS). The versatility and accuracy of this test kit will prove invaluable to boiler operators and chemical sales professionals. …

  • Nitrogen (Total) TNTplus, LR

    Hach

    For determination of Total Nitrogen by the Persulfate Digestion method, using TNTplus vials. Hach Method 10208, Low Range: 1-16 mg/L N. 25 tests/package.

  • Free and Total Chlorine TNTplus

    Hach

    For determination of Free and Total Chlorine by the DPD Method, using TNTplus vials. USEPA equivalent for reporting drinking water with Hach Method 10231. Range: 0.05 - 2.00 mg/L Cl2. 24 tests. *This product has not been evaluated to test for chlorine and chloramines in medical applications in…

  • Model BC-3 Complete Boiler and Cooling Water Test Kit

    Hach

    Proper maintenance and economy of operation of modern boilers and cooling towers require a careful balance between water quality parameters and treatment chemicals. This kit provides testing capability for alkalinity, chloride, hardness, sulfite, phosphate, pH, iron, silica, and total chlorine. …

  • Nitrate TNTplus, LR

    Hach

    Now USEPA approved for compliance monitoring under the Safe Drinking Water Act. For determination of Nitrate Nitrogen by the Dimethylphenol Method, using TNTplus vials. Hach Method 10206. Low Range: 0.23-13.5 mg/L NO3-N (1.0-60.0 mg/L NO3). 25 tests/package Reduce Errors with Bar-coded…

  • Chemical Oxygen Demand (COD) Reagent, TNTplus, UHR

    Hach

    For determination of Chemical Oxygen Demand (COD) by the Reactor Digestion Method, using TNTplus™ vials. Hach Method 10212. Range: 250-15,000 mg/L COD. Reduce Errors with Bar-coded Vials and RFID No Reagent Blank Necessary Innovative Vial and Reagent Delivery Helpful package design

  • Hydrogen Sulfide Test Kits

    Hach

    Resulting from the anaerobic decomposition of organic matter, hydrogen sulfide is present in many water supplies. Sewage and industrial wastes are other sources of sulfide pollution. Highly toxic, this compound has a characteristic rotten egg odor, which can be detected long before harmful…

  • Header, 2x7 Pin, 0.025 Square Pin

    Hach

  • Test Kit, Po-14 Phosphate

    Hach

    Color Disc/Stannous 100 tests

  • Total Nitrogen Reagent Set, HR, TNT

    Hach

    For determination of Total Nitrogen by the Persulfate Digestion Test 'N Tube method:  Hach Method 10072. Range: 10 - 150 mg/L N. 25-50 tests (dependent upon the number of reagent blank tests performed) Test 'N Tube products provide safe, convenient testing Easy…

  • CL17 Colorimeter Assembly

    Hach

    Replacement colorimeter for the newer version (manufactured since 4/2000) of the Cl17.

  • Chloride QuanTab® Test Strips

    Hach

    Chloride is found in nearly all natural waters and affects human taste above 250 mg/L. High levels inhibit plant growth, and many industrial processes need to limit chloride concentration. Contains 40 tests. Easy to use, disposable, and inexpensive A great way to obtain quick,…

Compare Tool

Select up to 3 products

Please Log In

Don't have an Account? Create one now.