Gas Chromatography Tools
-
Quartz Tube Insert
PerkinElmerThis tube insert is made of pure quartz and meant to be used with the optional oxygen analysis kit for the 2400 Series II CHNS/O Elemental Analyzer.
-
10µm Stainless Steel Solvent Reservoir Sparger
PerkinElmerSpargers connect directly to the solvent delivery line andare easily removed for cleaning.
-
-
By using rectangular windows instead of circular windows, the demountable cell becomes a semi-demountable cell. The semi-demountable cell can be used either as a demountable cell or as a sealed cell for high-viscosity liquids or mull samples. To order a semi-demountable cell, order the Universal…
-
Microsampling Tool Kit for FTIR Microscopy
PerkinElmerKits includes: Forceps (P/N N9302610), Roller Knife (P/N N9302619), Tweezers (P/N N9302609), Tungsten Needle (P/N N9302604), Probe (P/N N9302605), Handle tor Probe (P/N N9302622), Pin Vise (P/N N9302603).
-
Rechargeable Desiccant Kit for Spectrum 400 spare window compartment includes two rechargeable desiccant packs. One desiccant pack required per desiccant change.
-
Impact Bead for High Sensitivity Nebulizer with Pt/lr or Tantalum Capillary for PerkinElmer AAnalyst 100/300/700/800, 5100 PC, 5000,3300, 3110, 3100 4100, 2100, 1100(B)and earlier AAs. Included with High Sensitivity GemTip Nebulizer only. Inert plastic body with red adjusting ring
-
-
-
Clear Fused Quartz Rods
ChemglassCytiva Type 214 clear fused quartz rod. Rod is stocked in 4ft lengths. PLEASE NOTE: PRICE LISTED IS PER LENGTH OF 4FT ROD.
-
The pre-assembled Sodium Chloride Semi-Demountable Cell Kit from PerkinElmer is ideal for FT-IR analysis of high viscosity liquids and of mull samples.
-
OilExpress Flow Cell Windows made from Zelenium Selenide are available from PerkinElmer for analysis of oil samples using infrared sampling optics. Fitted to ensure moisture resistance.
-
A complete High Sensitivity plastic body nebulizer with Pt/Ir capillary and Viton o-rings. This nebulizer is fabricated of inert plastic materials for maximum performance and corrosion resistance. It's compatible with the PerkinElmer AAnalyst 200/400/700*/800* AA instruments. Note: The AAnalyst…
-
Spectroscopy Cell, Macro with PTFE Stopper, Special Optical Glass, Light Path: 10mm, Outside Dim: 46H x 12.5W x 12.5D mm, Inside Width: 9.5mm, Base Thickness: 1.5mm, Cell, Volume: 3.5mL, contain two clear windows, Pkg 2
-
Copper Gas Line Kit
PerkinElmerThe kIt includes: 2- 6 ft. lengths of 1/8 in. i. d. copper tubing with 1/8 in. Swagelok fittings at each end 2- 1/8 to1/4 in. fittings (09903087) 2- 1/8 to 1/8 in. fittings(09903434), and 1-roll of PTFE ® tape.
-
Fixed-Angle Specular Reflectance Accessory
PerkinElmerGood quality spectra can be obtained from films on glossy flat surfaces, shiny paper, metallic surfaces, and semiconductor wafers such as silicon and germanium using the PerkinElmer Fixed-Angle Specular Reflectance Accessory. You can also obtain high-quality spectra of surface-treated materials,…
-
Three 2-inch pieces of 99.99% nickel wire, Magnetic transition temperature of 355.3 C for TGS-2
-
-
ICP-OES Oil-less Air Compressor, 115V/60HZ
PerkinElmerHorse Power: 1.5 Hp Output CFM/Output L.: 6.0 CFM/170 L. Min Max Pressure PSI/Max Pressure Bar: 120 PSI/8 bar Noise Level: 72 dB/A, with Enclosure 55 dB/A Tank Size Gal./Tank Size L: 13 Gallons/50 Liters Dimensions: 25 x 18 x 29 / with Enclosure 29 x 23 x 32 Weight: 97 Lbs. / with…
-
10mm NIR Cylindrical Cell, SUP 300
PerkinElmerCylindrical cells are used with spectrophotometers that have a larger, circular light beam. Each cell has an outside diameter of 22 mm and an inside diameter of 19 mm. Each package contains one cell and two windows.
-
Specifications: Spectroscopy Cell, Micro with PTFE Lid, Special Optical Glass Light Path: 10mm Outside Dim.: 45H x 12.5W x 12.5D mm Inside Width: 2mm Base Thickness: 3.2mm Cell Volume: 700 mL Package: 2 Black versions.
-
Flow-through cells are used for measuring samples with continuous flow or with Sippers where individual samples are aspirated into the cell. All cells have center heights of 15 mm. Each package contains one cell with two clear windows. The cells listed below are Compact with two screw connectors,…
-
High solids GemCones are for samples with high dissolved solids (up to 20%). This conespray nebulizer allows you to analyze samples with higher solids concentration than is possible with a Cross-Flow nebulizer. GemCone nebulizers require an end cap for use with Scott Spray Chambers. This is a 10…
-
NITROGEN NITROFLOW LAB Generator 120volt
PerkinElmerThe Nitroflow Lab is a portable unit that offers a less expensive and more convenient delivery of nitrogen than cylinders and dewars. NitroFlow lab is a self contained LC/MS Membrane Nitrogen Generator with dual oil-less air compressors. NITROFLOW LAB Integrated Nitrogen Generator. System Includes…
-
AA and ICP Vent and Blower Kit - 115V
PerkinElmerNotice: Local electrical codes do not permit PerkinElmer Service Engineers to install the blower and vent assembly.
-
LC Standard Analytical Flowcell
PerkinElmerThe PerkinElmer LC standard analytical flow cell measuring 8 mm x 12 uL is designed to use with UV/vis detectors.
-
Combustion Tube for CHN Analysis, Quartz
PerkinElmerFused quartz has been chosen because of its very high purity and low thermal expansion rate. Because we care about your safety, all combustion tubes are pressure-tested to eliminate any tubes which might contain weak spots. In addition, stringent specifications are used to insure that the…
-
The cell windows are fused to the bodies by a special process which avoids deformation of the windows. This assures that the full width of the cell is usable and the nished cell dimensions are maintained. Our cells are manufactured from various types of glass. We offer three basic materials:…
-
Damaged or compromised components, disrupted processes, lack of reliability – they all add up to frustration, broken schedules and costly downtime. The problem is caused by a host of power disturbances – some visible and many invisible – that threaten your equipment’s operation every year. Power…
-
Capillary Assembly for Platinum Alloy Nebulizers
PerkinElmerStainless Steel body; this product is etched with a P for identification
-
-
This hyper skimmer cone o-ring is used with NexION 1000, 2000, 300 S, 300 Q, 300 X, 300 D and 350 ICP-MS series instruments. The o-ring is also for use with the 2400 Series II CHNS/O Elemental Analyzer.