Sterilization & Biological Indicators
-
Vapor Line® Steam Sterilization Integrators
Propper ManufacturingThe Vapor Line® integrator is a chemical indicator for monitoring the essential conditions of steam sterilization processes - saturated steam, temperature, and time in gravity displacement and pre-vacuum sterilizers operating in the 250°F - 272°F temperature range. The integrator…
-
Steri-Dot® Indicators
Propper ManufacturingSelf-adhesive Steri-Dot® Indicators offer a fast, positive visual check on items that were sterilized by Ethylene Oxide gas. They also display a Red for Stop, Green for Go color scheme. A Red Steri-Dot® indicates that the package or load has not yet passed through sterilization - a Green…
-
Steam Chemical Process Indicators (CPIs) are manufactured to meet performance specifications described in ISO 11140-1 “Sterilization of health care products - Chemical indicators - Part 1: General requirements,” for Class 1 Process Indicators. The blue-to-pink color transition is…
-
CSR Sterilization Wraps
CrosstexUse with EtO, steam, gamma irradiation, E-beam sterilization technology. Highest bacterial filtration efficiency (BFE) available. Highly permeable - no wet packs. Bacterial barrier to both airborne and waterborne contamination. Outstanding liquid repellency - water, alcohol, iodine. Even…
-
BI-O.K.® Self-Contained Biological Indicators
Propper ManufacturingPropper BI-OK® self-contained biological indicators for Steam and EO gas are designed for sterilization efficacy monitoring in hospitals, clinics, and for industrial applications. After processing in a sterilization cycle and activation of media by crushing the glass vial, indicators need to be…
-
Steam Sterilization Monitor Strips are used for evaluating sterilization process. These indicators which are specified by the U.S. military specification MIL-S- 36586 are GMP requirements of U.S. FDA. Appearance: Filter paper strip impregnated with spores of standard culture of…
-
Chex-All® Sterilization Tubes
Propper ManufacturingHeat-Sealable Chex-All® Tubes are premium quality sterile packaging products designed to reduce the cost of sterilization processing. The tubes have independent indicators imprinted on both inside and outside of every roll. While external indicators serve as process indicators, the internal…
-
Radiation Chemical Process Indicators (CPIs) are manufactured to meet performance specifications described in ANSI/AAMI/ISO 11140-1 “Sterilization of health care products - Chemical indicators - Part 1: General Requirements,” for Class 1 Process Indicators. The color transitions are…
-
Mini Self-Contained Biological Indicators (SCBIs) for Monitoring Steam Sterilization Processes, Geobacillus stearothermophilus Cell Line 7953, SCBIs each 8.4 mm x 45.5 mm, 10 5 population level, 25 per box, ISO 11138-1, 11138-3 and USP compliant where applicable.
-
Duo Record® Sterilization Record Keeping System
Propper ManufacturingLabel Applicators Direct reading dials on the label applicators allow the operator to set expiration date, sterilizer number, Julian calendar date, and load number according to the system used by the hospital. For use with Duo-Record® large labels. Each applicator is of a sturdy,…
-
BI-OK® Steam Test-Pak™
Propper ManufacturingSterilization processing of hospital goods can be tedious and error-prone. When you need the ultimate biological test for steam autoclave effectiveness, choose the BI-OK® steam test-pak™ - your guarantee of sterilization efficacy. With BI-OK® steam test-pak™ you can rest assured…
-
VERIFY™ Dual Species Self-Contained Biological Indicators (SCBIs) are for use in monitoring steam sterilization and ethylene oxide (EO) sterilization processes. Each SCBI is completely self contained within a vial and contains a disc inoculated with dual species bacterial spores (Geobacillus…
-
Hydrogen Peroxide Chemical Process Indicators (CPIs) are manufactured to meet performance specifications as described in ISO 11140-1 “Sterilization of health card products - Chemical indicators - Part 1: General Requirements,” for Class 1 Process Indicators. Hydrogen Peroxide CPIs are…
-
B/T Sure™ Biological Indicators
BarnsteadVerifies the sterility of your instruments, glassware and other products in just two days Simple, three step process Run indicator through standard sterilization cycle; compress plastic vial to break glass ampule inside and then incubate for a minimum of 48 hours. When complete,…
-
Apex® Biological Indicators
Mesa LabsApex Biological Indicators consist of stainless-steel carriers inoculated with sterilization resistant spores. Apex ribbons are inoculated on one end and flexible for easy placement.
-
Sterikon Plus Biological Sterilization Indicator
MilliporeSigmaFor monitoring the effectiveness of steam sterilization at 121°C for 15 minutes Easy-to-read; media’s color changes with growth Rapid results; read after 24 hours Sterikon ® Plus indicators contain nutrient broth, sugar, a pH indicator and spores of apathogenic bacillus…
-
Vapor Line® Reusable Steam Sterilization Process Challenge Test
Propper ManufacturingThe Vapor Line® Reusable Steam Sterilization Process Challenge Test is a reusable process challenge device for use in prevacuum steam sterilization processes at 273°F/134°C. It consists of a metal capsule with a removable cap equipped with a plastic holder for the Propper…
-
Gas-Chex® Sterilization Indicators
Propper ManufacturingGas-Chex® Sterilization Indicator Strips have the easiest-to-remember color scheme: Red for Stop (pack was not yet processed or the process was inadequate), and Green for Go. Gas-Chex® Strips are suitable for monitoring gas concentration and exposure, and are especially suitable for…
-
3M™ Comply™ Bowie-Dick Test Packs are used to monitor the performance of vacuum-assisted 132ºC - 134ºC (270ºF - 273ºF) steam sterilizers; test packs will reproducibly detect residual air in the sterilizer chamber due to air leaks, air removal failures and inadequate…
-
OK® Sterilization Indicator Strips
Propper ManufacturingFor steam sterilization cycles of 250°F (121°C) and 273°F (134°C) OK® Strips are indicators that monitor all critical sterilization arameters: steam, time, and temperature. In sterilization cycles OK® Strips guard against incomplete steam penetration, presence of…
-
Strate-Line® Steam Sterilization Strips
Propper ManufacturingStrate-Line Sterilization Indicator Strips are an economical alternative to OK strips and are designed for monitoring steam sterilization cycles at 250°F (121°C) and 273°F (134°C). It uses the same reactive ink as the OK strip. The correct endpoint is indicated when the…
-
Crosstex manufactures Bacillus subtilis (Cell Line 6633) Spore Suspensions utilized in low temperature (<121°C) steam sterilization processes. The Spore Suspensions are pure suspensions of spores with known steam resistance characteristics and a variety of population levels standardized per…
-
Self-Seal Sterility Maintenance Covers
Propper ManufacturingPlastic dust covers protect the sterile pack during storage, handling, and transportation from dust, moisture, or airborne contaminants, and extend sterile shelf life when definite shelf life terms are used. Self-Seal Dust Covers satisfy current regulations for sterility maintenance covers.
-
Kimtech™ Kimguard™ KC600 Sterilization Wrap (68654) 54ö x 54ö 48/cs
Kimberly-Clark ProfessionalKimtech™ Kimguard™ Sterilization Wrap is a must-have tool for sterile processing environments, such as in pharmaceuticals and medical devices. The line comes in six grades of wrap fabric, from KC 100 to KC 600, so you can get precisely the right protection for your needs. The…
-
PASS/FAIL® Steam Challenge Pack
Propper ManufacturingA single-use test pack designed to provide a challenge to 250°F gravity displacement and 273°F prevacuum sterilizers in modern hospital practice. Equivalent in performance to a biological indicator in the AAMI approved linen pack. Propper PASS/FAIL® Steam Challenge Pack PASS…
-
Paper Heat-Seal Sterilization Pouches
Cardinal HealthCardinal Health™ Paper Sterilization Pouch combines a blue film and a medical grade paper to provide breathability, sterile barrier, and indication of processing. Each pouch includes an external process indicator for Steam and Ethylene Oxide (EO) Gas sterilization. To assist opening, a…
-
Steam-Dot® Indicators
Propper ManufacturingSelf-adhesive Steam-Dot® Indicators offer a fast, positive visual check on items that were sterilized by steam.
-
Record Keeping Envelopes
Propper ManufacturingSeparate color-coded envelopes for steam and EO gas sterilization: Each envelope is specifically designed for its sterilization process, and contains checklists for operators All essential data is in one place: Each envelope holds charts, indicators, Duo-Record cards and biological monitoring…
-
Twindicator® Sterilization Indicators
Propper ManufacturingTwindicator® is an indicator designed for monitoring all critical parameters of steam sterilization cycles at 250°F (121°C) and 273°F (134°C). Twindicator® adds extra flexibility in sterilization monitoring: each 8” strip is perforated to allow for two 4” strips.…
-
SporAmpule® Liquid Biological Indicators
Hardy DiagnosticsMonitoring your autoclave couldn’t be easier with the convenient SporAmpule. Easy to use! Process one or more SporAmpules, along with your normal load, then incubate at 55-60°C for 48 hours and observe for a color change. No activation, crushing, or additional culture media is…
-
Dry Heat Chemical Process Indicators (CPIs) are designed to signal, through a transition in color, when exposed to high temperatures such as dry heat and steam sterilization or depyrogenation processes. The CPIs will transition from the initial to the signal color depending on the temperature and…
-
Duo-Spore® Biological Indicator System
Propper ManufacturingFor monitoring the efficacy of steam, ethylene oxide gas, chemical vapor and dry heat sterilization processes used in healthcare facilities, body modification parlors and industry. Biological monitoring is recommended weekly, but preferably daily, and with every load containing implants.…