  • General Purpose Viscosity Standards

    Cannon Instrument

    Based on NIST value of 1.0016 centipoise for water at 20C; conforms to ASTM Standards D 445, D 88 and D 2161; traceable to NIST Approximate viscosities at varying temperatures in centistokes and centipoises are given in Table 1; each standard is furnished with actual viscosity and density…

  • Silicone Viscosity Standards

    Cannon Instrument

    For calibration of rotational viscometers Viscosity certified at 20, 23, 24, 25, 26 and 27°C Calibrated to a precision of ±0.2% NIST traceable Standards are based on the National Institute of Standards and Technology (NIST) value of 1.0016 mPa-s (centipoise) for…

  • General Purpose Low Temperature Viscosity Standards

    Cannon Instrument

    CANNON Low Temperature Viscosity Standards verify viscometer performance at sub-zero temperatures. These standards are applicable to SAE Specification J300 as well as a variety of ASTM Methods including: ASTM D2983, Low-Temperature Viscosity of Lubricants Measured by Brookfi eld…

  • Cold Cranking Simulator Viscosity Standards

    Cannon Instrument

    Conform to SAE specification J300 and ASTM D 5293 Viscosities based on NIST value of 1.0016 centipoise for water at 20°C Traceable to NIST Supplied in one pint bottles

  • Ink and Paint Viscosity Standards

    Cannon Instrument

    For ink and paint viscometers For use with Zahn, Shell and Ford viscometer cups. Based on NIST value of 1.0016 centipoise for water at 20°C. Traceable to NIST. Approximate kinematic viscosity and drain times for the various cups at 25°C are given in table. Actual values are furnished…

  • Cold-Cranking Simulator Standards

    Cannon Instrument

    CANNON CL Standards provide certified dynamic viscosity data (in cP or mPa·s) at temperatures from –5°C to –35°C. These standards are used to calibrate the CANNON Cold-Cranking Simulator (CCS) oil testing (see ASTM D 5293 and SAE Specification J300).

  • High Viscosity Standards

    Cannon Instrument

    For determining viscosities in asphalt and polymers (see ASTM D 2170 and D 2171) Traceable NIST For Kinematic Viscosity Values (cSt), please contact Thomas Scientific

  • Paint Viscosity Standards

    Cannon Instrument

    For Thomas®-Stormer® Viscometers Based on NIST value of 1.0016 centipoise for water at 20°C. Traceable to NIST. Approximate viscosity in centipoise and Krebs unit values at 25°C are given in table below. Actual value are furnished with each standard. Supplied in a one pint bottle.

  • High-Temperature Viscosity Standards

    Cannon Instrument

    For use with Cannon High Temperature/ High Shear Viscometers for measurements at 150°C and 10 -6 s -1 shear rate Based on NIST value of 1.0016 centipoise for water at 20°C; traceable to the NIST In accordance with ASTM Standard D 4624 9727U92 and U94 are non-Newtonian…

  • 2mL Empty Columns

    Eichrom

    The same columns used for our standard 2mL pre-packed columns, these polypropylene columns have an inner diameter of 0.8cm and a snap off tip. Use when a slightly different sized column is required for the analysis. The columns are supplied in packages of 100, with 100 caps, bottom frit inserted…

  • 20mL Empty Columns

    Eichrom

    These columns, nominally 20mL, have an inner diameter of 1.5 cm and a "packable" volume of 17mL. Use them when a large bed volume of one of Eichrom's extraction chromatography or ion exchange resins is required. Columns are supplied with bottom frit pre-inserted, in packages of 20,…

  • Gas Analyzer Standards And Accessories

    Agilent Technologies

    Gas Analyzer Standard Kits (2714T95 to T97) Calibration kits contain one box of 2 calibration mix cylinders, 2 regulators, 2 pieces of stainless steel 1/16 in. gas sampling tubing, and 1 carry case, all packaged separately. Gas Analyzer Standard Cylinders (2714T90 to T94) Cylinder…

  • Certified Viscosity “Check Oils” for SAE Target Viscosities

    Cannon Instrument

    CANNON Instrument Company has released a line of viscosity check oils specifically designed for verification of SAE target viscosities per ASTM D 445, D 5293, and D 4684. The CVCO (Certified Viscosity Check Oil) series includes formulated commercial engine oils with certified values for kinematic…

  • SPEC Disk SPE

    Agilent Technologies

    SPEC Disk SPE delivers superior flow characteristics and trouble free automation.

  • Viscosity Standard, -20 and -25°C for CMRV, 500 ml

    Cannon Instrument

    For preceding the borderline pumping temperature of engine oil in accordance of ASTM Standards D 3829 and D 4684 Viscosity of 30,000 centipoise at -20°C based on NIST value of 1.0016 centipoise for water at 20°C; traceable to NIST

  • Cartridge Vacuum Box

    Eichrom

    This 24 hole vacuum box has a high density polyethylene (HDPE) top for acid compatibility and a clear plastic bottom for visibility of collection tubes. Overall dimensions are 57 cm (long) x 14.5 cm (deep) x 18 cm (high.) The box comes complete with a screw in vacuum gauge, a rack insert which…

  • Bond Elut NEXUS

    Agilent Technologies

    Bond Elut NEXUS is an ultra-clean, large particle size polymeric SPE ideal for highly viscous samples, available in non-polar or weak cation exchange.

  • Bond Elut C18 OH

    Agilent Technologies

    Bond Elut C18 OH is excellent for balanced retention of polar analytes.

  • ICP-MS Standards

    Agilent Technologies

  • Sr Resin

    Eichrom

    The extractant system in Eichrom's Sr Resin is 1.0M 4,4'(5')-di-t-butylcyclohexano 18-crown-6 (crown ether) in 1-octanol.A 40% (w/w) loading of this organic solution is loaded onto an inert chromatographic support. The bed density of Sr Resin is approximately 0.35 g/mL.

  • UV-Vis Standards And Reagents

    Agilent Technologies

    In recent years, quality requirements as outlined by ISO 9000, GLP, GMP and NAMAS have assumed increasing importance. As a consequence, the recommendations of pharmacopoeias have become more influential in the pharmaceutical industry. Formal performance verification of UV-Visible spectrophotometers…

  • Bond Elut Sodium Sulfate Drying Cartridges

    Agilent Technologies

    Bond Elut Sodium Sulfate Drying Cartridges simplify drying processes with pre-packed devices.

  • Silicone Rotational Viscosity Standards

    Fungilab

    Fungilab's silicone rotational viscosity standards are essential for the calibration of rotational viscometers. Silicone standards are ISO 17025 / ISO Guide 34 certified and are ready to use in convenient 600mL packs, eliminating the need to transfer sample fluids to a test beaker. Fungilab's…

  • Agilent GC Column Test Standards

    Agilent Technologies

    Column Test Standards validate the performance of your Agilent columns by checking such components as polarity and inertness. These standards help ensure the quality of your chromatograms.

  • DGA Resin

    Eichrom

    Eichrom’s DGA Resins are extraction chromatographic materials in which the extractant system is either N,N,N’,N’-tetra-n-octyldiglycolamide (DGA Resin, Normal) or N,N,N’,N’-tetrakis-2-éthylhexyldiglycolamide (DGA Resin, Branched). The bed density of both DGA Resins is approximately 0.38 g/mL, with…

  • 20mL Cartridge Reservoirs

    Eichrom

  • LC and LC/MS Standards

    Agilent Technologies

  • Viscosity Standards

    Fungilab

    Viscosity standards are ideal for the calibration of dynamic and kinematic viscosity instrumentation. Standards are supplied at 500mL and must be used with a supplementary beaker. All viscosity standards are delivered with a certificate of analysis and are ISO 17025 / ISO Guide 34 certified.…

  • Bond Elut C18

    Agilent Technologies

    Bond Elut C18 is the most hydrophobic silica sorbent available in this range. It is the most popular SPE sorbent because of its extreme retentive nature for non-polar compounds.

  • Bond Elut C8

    Agilent Technologies

    Bond Elut C8 is very similar in property to C18, but is not as retentive for non-polar compounds due to its shorter hydrocarbon chain and therefore reduced carbon loading. C8 is an excellent replacement for C18 when analytes are too strongly-retained for effective elution. The potential for polar…

  • LC And GC/MS Standards And Reagents

    Agilent Technologies

    GPC-SEC Calibration Standards (2714X77 to X79) Three different polystyrene standard kits are available for organic GPC column calibration. Each kit contains individual monodisperse polymers that cover low, medium and high molecular weight ranges. Each standard lot is characterized using low-angle…

  • Bond Elut ENV

    Agilent Technologies

    Bond Elut ENV, a PS/DVB polymer, is designed for the extraction of polar organic residues. It contains 125 µm spherical particles with a high degree of cross linking, advantageous for high volume, fast flow-through applications.