  • ROSS® Sure-Flow® pH Electrodes

    Thermo Scientific Orion

    Ross® Sure-Flow Easy cleaning in waste-waters, food samples, colloids, soils and slurries Has optimum flow rate for high purity waters, drinking waters and buffers Produces fast, stable responses in samples that vary in temperature pH range is 0-14 over a temperature range of…

  • 3-in-1 Triode Probes

    Thermo Scientific Orion

    Orion Triode 3-in-1 Probe is a practical solution for field and plant use. The pH/Reference/ATC probes are all in one body. It's non-refillable, little or no maintenance required. You get portability and accuracy in one package.

  • Orion ROSS® 3-in-1 Triodes

    Thermo Scientific Orion

    pH and temperature measurement with one electrode Superior stability with high accuracy pH and temperature measurement Fast pH response even in samples at varying temperatures Compatible with Mettler-Toledo TM Five and Seven Series meters and others which accommodate NTC30 thermisters with…

  • Orion Ion Selective Electrodes (ISE)

    Thermo Scientific Orion

    Measurements using an ion selective electrode (ISE) are applicable in virtually every laboratory. ISEs can be used to measure ion concentrations in water, food, pharmaceuticals and biological samples. Ion selective electrodes can be used as endpoint indicators or to perform direct measurement and…

  • Ammonia Ion Electrode Accessories

    Thermo Scientific Orion

    Accessories: Ionic Strength Adjusting Solution (ISA) adjusts the pH of standards and samples used in ammonia measurements. Ammonia Standard Solutions; 0.1 M ammonium chloride or 1,000 ppm as N. Replacement Membranes or Membrane Caps; Loose membranes for probes with O-Ring membrane holder;…

  • Orion DuraProbe 4 Electrode Conductivity Cells

    Thermo Scientific Orion

    Wide conductivity range For lab and field applications Rugged epoxy/graphite MiniDIN connector DuraProbe 4-electrode cells provide the highest accuracy for demanding laboratory or field applications. The 4-electrode design compensates for electrode fouling, cable and connector…

  • ROSS® Ultra Premium pH Electrodes

    Thermo Scientific Orion

    The Orion ROSS® pH electrode, which is recognized as the best pH electrode in the world for difficult samples, is now even better. The Orion ROSS® Ultra has twice the warranty and greater stability than its predecessor. It uses a unique reference system developed by Thermo Scientific that offers…

  • High Performance Ammonia Electrode

    Thermo Scientific Orion

    Designed to meet the demanding needs of drinking water and wastewater applications Accurate results down to 0.01 ppm Linear electrode response down to low detection limits Response time of 1 minute in sample concentrations of 1 ppm and higher New wastewater applications developed using known…

  • Reference Electrodes For ISEs

    Thermo Scientific Orion

    4215F10 Mercury-free, Ag-AgCl type, with sleeve junction. Designed for use with Thermo Orion ion-selective electrodes as indicated in respective descriptions; usable also with glass electrodes for pH measurement. Range 10 to 100°C. Length 140 mm, diameter 13 mm. Diameter of mounting cap 16 mm. …

  • Fluoride Ion Electrode

    Thermo Scientific Orion

    4210F12 For determination of fluoride ion activity in concentrations from saturated to 10 -6 M (0.02 ppm) Method approved by ASTM for water, drinking water, wastewater and seawater brines and it is approved by EPA, Standard Methods and AOAC for feeds Range saturated to 0.02 ppm Requires…

  • Nitrate Ion Electrode

    Thermo Scientific Orion

    4210S12 Polymer membrane electrodes measure nitrate concentration in the range of 14,000 to 0.1 ppm in soils, plant materials, fertilizers, pickling baths and other aqueous solutions. Other uses listed in Standard Methods. EPA approved for NIPDWR compliance monitoring Optimal temperature range…

  • Standard Ag/AgCl pH electrodes

    Thermo Scientific Orion

    Ideal for all routine pH measurements. A large variety of quality electrodes for a wide range of applications. Includes specialty pH electrodes for unique or challenging pH measurements.

  • Orion Redox / ORP / Temp Electrodes

    Thermo Scientific Orion

    The Orion 9179BNMD and Orion 9180BNMD consist of a platinum redox sensor, a silver/silver chloride internal reference systems and a built-in thermistor for Automatic Temperature Compensation (ATC). Both models have the capability to measure ORP and Temperature simultaneously without a separate…

  • ROSS® Combination Electrodes

    Thermo Scientific Orion

    Superior stability pH range 0-14 Temperature of 0°-100°C 3 M KCl filling solution supplied with electrode

  • ROSS® Ultra Refillable Glass Triode

    Thermo Scientific Orion

    pH and temperature measurement with one electrode Versatile with chemically compatible glass body, refillable with ROSS 3M KCL solution or a fill solution compatible to your sample type Fast pH response even in samples at varying temperatures Compatible with Mettler-Toledo TM Five and…

  • pH Electrode Stand

    Thermo Scientific Orion

    Electrode holders and stands Electrode holders and stands permit one-handed operation of electrode movement Four-position holders allow simultaneous use of pH or ISE electrode and reference half cell Swing arm stand (0732H82) allows flexible movement of electrodes. Holder and stand (4153Y35)…

  • Micro-pH Combination Electrode, NMR, Thermo Orion 9826BN

    Thermo Scientific Orion

    Immersion depth is 2 mm, designed for NMR cells. pH range is 0-14. Temperature range is -5 to 100°C. Dimensions: 228 mm x 2.5 mm; tip diameter: 2.5 mm. Type reference: Ag/AgCl.

  • Economy pH Electrodes

    Thermo Scientific Orion

    Ideal for field, plant, or educational applications Connector type: BNC Waterproof

  • Sodium Ion Electrode

    Thermo Scientific Orion

    ROSS, Half Cell ISE For determination of Na+ ion activity in concentrations from saturated to 10 -6 M (saturated to 0.02 ppm) Model 4210E63 ROSS electrode requires Thomas number 4153Q87 or 0732K95 reference electrode. Uses Orion 900004 fill solution, order as 4153F22. Accessories: Sodium…

  • Orion™ pH Electrode Filling Solution

    Thermo Scientific Orion

    Use Thermo Scientific™ Orion™ pH Electrode Filling Solution with pH electrodes and reference electrodes. Packaged as five 2 oz. (5 x 60mL) bottles.

  • ORP Standard

    Thermo Scientific Orion

    Calibration solution (4153R53) does not contain hazardous chemicals, is stable for up to one year (unopened) and can be used directly from the bottle with no mixing or diluting.

  • AquaPro Professional pH Electrodes

    Thermo Scientific Orion

    The patented reference system and the double junction design keeps silver ions from contacting the sample. These electrodes are non-refillable, offering the benefits of ease of use and minimal preparation.

  • Orion Dissolved Oxygen Probes

    Thermo Scientific Orion

    Durable and accurate DO probe for the lab or field. Cable lengths 1.5 - 20m. Compatible with Star Series meter. Mini DiN connector.

  • Triode pH Combination Electrode

    Thermo Scientific Orion

    Combination pH and ATC in a single barrel pH range: 0-14 Temperature range: 0-90°C Recommended for general purpose use. Built-in thermistor for automatic temperature compensation. Useful for field pH measurements with Thermo Orion portable pH meters. BNC type connector. ATC…

  • ATC Probes

    Thermo Scientific Orion

    Orion Automatic Temperature Compensation (ATC) probes transmit a signal to the pH meter, which automatically corrects pH measurements for variation in electrode slope due to temperature change.

  • Electrode Holder

    Thermo Scientific Orion

    With 5 holes to take Thermo Orion ion-selective electrodes or gas sensing electrodes, as well as reference and pH electrodes and temperature compensating probes. Gas sensing electrodes are supported at 20° angle, to avoid entrapment of air bubbles in sensing tip. Fits support rods 5/16 or …

  • Nitrate Sensing Module

    Thermo Scientific Orion

    Replacement Module for Nitrate Half-Cell Electrode (9307BNWP).

  • Orion ROSS® Sure-Flow® Sodium Electrodes

    Thermo Scientific Orion

    The Orion 8411BN ROSS™ Sodium and Orion 8611BNWP ROSS Sodium Combination Electrodes allow sodium in aqueous solutions to be measured quickly, accurately, and economically. With its unique redox internal system, the ROSS electrode provides faster response, greater stability and accuracy than…

  • pH Electrode Accessories

    Thermo Scientific Orion

    Adapters and Cables 4153X20 adapts electrodes with US Standard Connector for use with meters which have BNC Jack 4153X30 adapts electrodes with BNC Jack for use with meters which have US Standard Cables for screw cap electrodes allow a Thermo Orion electrode to fit any pH meter Cables for…

  • Orion A Series Electrode Holder/Stand

    Thermo Scientific Orion

    Use the Thermo Scientific™ Orion™ Electrode Holder and Stand as a station for sample container and vertical adjustment of electrode. This holder is for use with Orion™ meters. Recommended for Orion A, A+, Thermo Scientific™ PerpHect™ and pHuture™ Series Meters

  • Orion Double Junction pH Electrodes

    Thermo Scientific Orion

    Low maintenance and refillable electrodes that features an isolated Ag/AgCl reference system, so silver does not make contact with the sample.

  • COMBINATION pH ELECTRODES AND ACCESSORIES

    Thermo Scientific Orion

    Conduct routine pH measurements with the Thermo Scientific™ Orion™ Economy Series pH Combination Electrode, a routine wick junction, gel-filled electrode. Its unbreakable epoxy body extends beyond the pH sensing glass bulb for rugged conditions. It provides durability for lab or field…