Restek Gas Chromatography Columns
-
low-polarity phase; Crossbond diphenyl dimethyl polysiloxane Rxi fused silica capillary GC columns were designed specifically to be the best columns available, for exceptional inertness, ultra-low bleed, and reproducible retention and selectivity. In addition to outstanding performance, this…
-
Stabilwax-MS columns ensure reproducible retention times from run to run, even with temperature cycling. When methods require trace analysis, this highly polar, low-bleed stationary phase produces excellent signal-to-noise levels! Ideal for food and flavor analysis (e.g., essential oils), fragrance…
-
D3606 Application Column Set
RestekConforms to the specifications established in the current ASTM method D3606 for the quantitation of benzene and toluene in spark ignition fuel containing ethanol. Complete resolution of benzene from ethanol—no compromising coelutions. Accurate quantification of benzene and toluene.…
-
low-polarity phase; Crossbond diphenyl dimethyl polysiloxane General purpose columns for drugs, solvent impurities, pesticides, hydrocarbons, PCB congeners (e.g., Aroclor mixes), essential oils, semivolatiles. Column specifically tested for low-bleed performance. Temperature range:…
-
Extend analytical column lifetime by preventing degradation from harsh “steam-cleaning” water injections. Tested with a comprehensive test mix, to ensure high inertness Maximum temperature: 325°C When transfer lines from purge-and-trap systems, air monitoring equipment,…
-
low- to midpolarity phase The unique polarity of "624" columns makes them ideal for analyses of volatile organic pollutants. Although the MXT-502.2 column is recommended in many methods, MXT-624 columns offer the best separation of the early-eluting gases. Application-specific…
-
Accurate quantification of toluene and benzene—including benzene in gasoline containing ethanol or butanol blends. Complete resolution of benzene from ethanol—no compromising coelutions. Enhanced formulation with improved support material and polymers—more robust and reproducible. Column sets…
-
Restek's R&D chemists have optimized the deactivation technology applied to our MXT-Alumina BOND/MAPD column for improved analysis of trace concentrations of polar hydrocarbons like acetylene, methyl acetylene, and propadiene in hydrocarbon streams containing higher levels of C1-C5…
-
2,3-di-O-ethyl-6-O-tert-butyl dimethylsilyl beta cyclodextrin added into 14% cyanopropylphenyl/86% dimethyl polysiloxane By adding β or γ cyclodextrin to our bonded Rtx-1701 stationary phase, we greatly enhance overall utility and column lifetime for our chiral columns, compared to…
-
low- to midpolarity phase General-purpose columns for residual solvents, alcohols, oxygenates, and volatile organic compounds. Temperature range: -20°C to 280°C. Equivalent to USP G43 phase. 4.5" standard coil diameter.
-
Restek GC Packing Material
RestekHayeSep® porous polymers are macroporous, spherical, ultrapure resins for performing unique separations in gas chromatography. Columns packed with HayeSep® polymers produce lower bleed and more reproducible characteristics than those packed with any competing polymeric product, and they require…
-
permethylated beta cyclodextrin added into 14% cyanopropylphenyl/86% dimethyl polysiloxane By adding β or γ cyclodextrin to our bonded Rtx-1701 stationary phase, we greatly enhance overall utility and column lifetime for our chiral columns, compared to columns that have pure…
-
proprietary Crossbond diphenyl/dimethyl polysiloxane phase An MXT-502.2 column will enable you to quantify all compounds listed in U.S. EPA Methods 502.2 or 524.2, whether you use a mass spectrometer or a PID in tandem with an ELCD. The diphenyl/dimethyl polysiloxane based MXT-502.2 stationary…
-
midpolarity Crossbond phase Rxi fused silica capillary GC columns were designed specifically to be the best columns available, for exceptional inertness, ultra-low bleed, and reproducible retention and selectivity. In addition to outstanding performance, this combination of column…
-
porous divinylbenzene homopolymer Porous polymers are unique, highly retentive stationary phases with a wide application range that are able to elute both polar and nonpolar compounds. They are very hydrophobic, so water has no impact on retention times and even elutes as a good chromatographic…
-
polar polyethylene glycol deactivation Tested with a comprehensive test mix to ensure high inertness Polyethylene glycol deactivation layer provides optimum wettability for polar compounds Minimize peak splitting when using polar solvents such as methanol or water Compatible with…
-
2,3-di-O-propyl-6-O-tert-butyl dimethylsilyl beta cyclodextrin added into 14% cyanopropylphenyl/86% dimethyl polysiloxane By adding β or γ cyclodextrin to our bonded Rtx-1701 stationary phase, we greatly enhance overall utility and column lifetime for our chiral columns, compared to…
-
Advantages of metal MXT PLOT columns include: Can be made in small coil diameters—perfect for tight spaces. Rugged material withstands rough handling and shock. Designed for robust performance in process GCs and field instruments. Available in 3.5"-coil diameter or…
-
polar phase; Crossbond polyethylene glycol The elution order of polyunsaturated FAMEs on FAMEWAX columns is comparable to that on other Carbowax columns, but baseline resolution is achieved in significantly less time. Application-specific columns for FAMEs, specially tested with a FAME…
-
proprietary Crossbond diphenyl/dimethyl polysiloxane phase Rtx-Volatiles columns were the first columns designed specifically for analyses of the 34 volatile organic pollutants listed in U.S. EPA methods 601, 602, and 624. With these columns, you can quantify all compounds listed in these…
-
low-polarity phase; Crossbond 1,4-bis(dimethylsiloxy)phenylene dimethyl polysiloxane Rxi fused silica capillary GC columns were designed specifically to be the best columns available, for exceptional inertness, ultra-low bleed, and reproducible retention and selectivity. In addition to…
-
Useful as guard columns, transfer lines, or long retention gaps Inertness-tested with the Grob test mix includes test chromatogram. 5-meter banded sections mounted in a Restek cage. Maximum temperature: 325°C Note: 30- and 60-meter lengths are banded in 5-meter sections. …
-
midpolarity phase; Crossbond trifluoropropylmethyl polysiloxane Rtx-200 columns have accomplished many difficult separations not possible on any other bonded stationary phase. Many analysts consider these the best, most inert midpolarity columns available. The trifluoropropylmethyl polysiloxane…
-
Rtx-1 Columns (fused silica)
Resteknonpolar phase; Crossbond dimethyl polysiloxane General-purpose columns for solvent impurities, PCB congeners (e.g., Aroclor mixes), simulated distillation, arson accelerants, gases, natural gas odorants, sulfur compounds, essential oils, hydrocarbons, semivolatiles, pesticides, oxygenates. …
-
100% divinylbenzene Porous polymers are unique, highly retentive stationary phases with a wide application range that are able to elute both polar and nonpolar compounds. They are very hydrophobic, so water has no impact on retention times and even elutes as a good chromatographic peak. The…
-
midpolarity Crossbond phase General-purpose columns for alcohols, oxygenates, PCB congeners (e.g., Aroclor mixes), and pesticides. Equivalent to USP G46 phase 4.5" standard coil diameter
-
polar phase; Crossbond base-deactivated Carbowax polyethylene glycol—for amines and basic compounds Stabilwax-DB columns reduce adsorption and improve responses for many basic compounds, without analyte derivatization or column priming. For different selectivity of basic compounds, or…
-
3x faster multiresidue pesticides analysis in foods. Factory-coupled, leak-free kit makes setting up LPGC as simple as a column change. Ideal for speeding up GC-MS and GC-MS/MS methods. Integrated transfer line reduces background and stabilization time.
-
polar phase; Crossbond cyanopropylmethyl phenylmethyl polysiloxane The cyanopropyl-containing Rtx-225 phase is slightly less polar than bonded polyethylene glycol (PEG) phases, but it can be used for many of the same applications. Improvements to the Rtx-225 polymer have increased thermal…
-
Restek Rt-Alumina BOND columns are highly selective for C1–C5 hydrocarbons and separate all saturated and unsaturated hydrocarbon isomers above ambient temperatures. The reactivity of the aluminum oxide stationary phase is minimized, by deactivation with inorganic salts like KCl or…
-
2,3-di-O-methyl-6-O-tert-butyl dimethylsilyl beta cyclodextrin added into 14% cyanopropylphenyl/86% dimethyl polysiloxane By adding β or γ cyclodextrin to our bonded Rtx-1701 stationary phase, we greatly enhance overall utility and column lifetime for our chiral columns, compared to…
-
midpolarity proprietary phase The Rxi-PAH GC columns were designed by Restek with a higher phenyl-content stationary phase that provides unique selectivity to separate important polycyclic aromatic hydrocarbons (PAH) for food safety that cannot be distinguished by mass spectrometry. Even…