Restek Chromatography Columns
-
2,3-di-O-propyl-6-O-tert-butyl dimethylsilyl beta cyclodextrin added into 14% cyanopropylphenyl/86% dimethyl polysiloxane By adding β or γ cyclodextrin to our bonded Rtx-1701 stationary phase, we greatly enhance overall utility and column lifetime for our chiral columns, compared to…
-
CarboBlack Columns
RestekGraphitized carbon black offers unique selectivity and very little adsorption for alcohol analyses. Two types of CarboBlack supports are available, CarboBlack B and CarboBlack C. CarboBlack B support, with its higher surface area, can hold up to a 10% loading of a nonsilicone liquid phase.…
-
Viva HPLC Columns: 3 or 5 µm particles; 300 Å pore size Excellent for separating peptides or proteins Rugged, spherical particles with 300 Å pore size High proportion of pore/surface area available to large molecules Viva columns are based on a wide pore material…
-
low- to midpolarity phase Many analysts feel the Rtx-1301 column has the best cyanosiloxane bonded stationary phase available, with no other column manufacturer providing lower bleed, longer lifetime, or better inertness. Our polymer is fully characterized to ensure long-term reproducibility,…
-
Roc HPLC columns are built to be the cornerstone for your LC lab. These solid, reliable columns are pressure rated for any 400 bar HPLC system and deliver the peak shape, reproducibility, ruggedness, and performance you demand for all of your conventional HPLC applications. An exceptional value,…
-
Column bleed, measured by ECD, is extremely low at temperatures up to 330°C, which is critical for baking-out the column to remove high-boiling compounds commonly found in pesticide/PCB extracts. An analysis time of less than 10 minutes improves throughput compared to other stationary phases. …
-
PLOT Column Particle Trap
RestekThe technology used to adhere particles in PLOT columns is excellent; however, it is still possible for particles to dislodge when extreme pressure shocks and gas flow changes occur. This sometimes happens when valve switching or backflushing is used. In those cases, using particle traps is…
-
Extend column lifetime. Excellent inertness—obtain lower detection limits for active compounds. Sharper chromatographic peaks by utilizing retention gap technology. Maximum temperature: 360°C
-
ShinCarbon ST Columns
RestekAnalyze oxygen, nitrogen, methane, carbon monoxide, and carbon dioxide with one column at room temperature. ShinCarbon ST material, a high surface area carbon molecular sieve (~1,500 m 2 /g), is the ideal medium for separating gases and highly volatile compounds by gas solid chromatography (GSC).…
-
Chemists using guard columns in the analyses of basic compounds frequently observe peak tailing and low recovery. This happens because conventionally deactivated tubing surfaces can be adsorptive to basic compounds. Restek offers base-deactivated guard columns, as well as base-deactivated inlet…
-
polar phase; Crossbond polyethylene glycol The elution order of polyunsaturated FAMEs on FAMEWAX columns is comparable to that on other Carbowax columns, but baseline resolution is achieved in significantly less time. Application-specific columns for FAMEs, specially tested with a FAME…
-
Easy scale-up from Restek analytical columns Popular bonded phases Restek makes it easy to scale up your separations. We offer a wide range of semipreparative and preparative-scale columns packed with many of our popular Ultra, Allure, Pinnacle DB, and Viva bonded phases on a 5 μm…
-
midpolarity phase; Crossbond 35% diphenyl/65% dimethyl polysiloxane Active basic compounds that otherwise require derivatization, or an alternative analytical technique, can be analyzed on an Rtx-35 Amine column. The tubing surface is chemically altered to reduce tailing of basic compounds,…
-
Ultra C4 Columns (USP L26)
RestekUltra HPLC Columns The Ultra line represents Restek’s broadest selection of stationary phases on a single silica support. Made of high-purity, type-B silica that minimizes activity and creates high-density bonding, these columns are designed for selective and reliable HPLC applications. …
-
Resprep Diol SPE Cartridge
RestekHigh-quality, silica-based adsorbents. Used for common sample matrices such as food and water. Stable over the pH range (2 – 8).
-
polar polyethylene glycol deactivation Tested with a comprehensive test mix to ensure high inertness Polyethylene glycol deactivation layer provides optimum wettability for polar compounds Minimize peak splitting when using polar solvents such as methanol or water Compatible with…
-
nonpolar phase; Crossbond 100% dimethyl polysiloxane—for simulated distillation The Rtx-2887 column's stationary phase, column dimensions, and film thickness have been optimized to exceed the resolution and skewing factor requirements specified in ASTM Method D2887. Each column is…
-
Restek Rt-Alumina BOND columns are highly selective for C1–C5 hydrocarbons and separate all saturated and unsaturated hydrocarbon isomers above ambient temperatures. The reactivity of the aluminum oxide stationary phase is minimized, by deactivation with inorganic salts like KCl or…
-
nonpolar phase Accurate boiling point determination for medium and heavy fractions using GC simulated distillation requires columns and phase polymers that are robust enough to withstand high temperatures without significant degradation. Lowest bleed for longest column lifetime. …
-
Molecular Sieve Columns
RestekMolecular sieve packed columns easily separate permanent gases at above-ambient temperatures. Restek’s R&D chemists have developed a process for preparing molecular sieve packings, which results in excellent batch-to-batch reproducibility. In addition, our molecular sieves are…
-
Ultra C18 Columns (USP L1)
RestekUltra HPLC Columns The Ultra line represents Restek’s broadest selection of stationary phases on a single silica support. Made of high-purity, type-B silica that minimizes activity and creates high-density bonding, these columns are designed for selective and reliable HPLC applications. …
-
Restek GC Packing Material
RestekHayeSep® porous polymers are macroporous, spherical, ultrapure resins for performing unique separations in gas chromatography. Columns packed with HayeSep® polymers produce lower bleed and more reproducible characteristics than those packed with any competing polymeric product, and they require…
-
Easy scale-up from Restek analytical columns Popular bonded phases Restek makes it easy to scale up your separations. We offer a wide range of semipreparative and preparative-scale columns packed with many of our popular Ultra, Allure, Pinnacle DB, and Viva bonded phases on a 5 μm…
-
Restek Rt-Alumina BOND columns are highly selective for C1–C5 hydrocarbons and separate all saturated and unsaturated hydrocarbon isomers above ambient temperatures. The reactivity of the aluminum oxide stationary phase is minimized, by deactivation with inorganic salts like KCl or…
-
Developed specifically for challenging analyses of polycyclic aromatic hydrocarbons (PAHs). The Pinnacle II PAH stationary phase incorporates a proprietary C18 bonding that enables unique shape selectivity to baseline-resolve all 16 PAHs listed in U.S. EPA Method 610 plus two other routinely…
-
proprietary Crossbond phase These columns separate to baseline all blood alcohol compounds in blood, breath, or urine, in less than 3 minutes, under isothermal conditions. Isothermal analysis increases productivity by eliminating the need for oven cycling. Confirmation is easily achieved with…
-
nonpolar phase; Crossbond 100% dimethyl polysiloxane—for simulated distillation MXT-2887 columns' stationary phase, column dimensions, and film thicknesses have been optimized to exceed the resolution and skewing factor requirements specified in ASTM Method D2887. Each column is…
-
Useful for a wide range of applications Compatible with most common solvents Maximum temperature: 325°C
-
low-polarity phase; Crossbond diphenyl dimethyl polysiloxane General purpose columns for drugs, solvent impurities, pesticides, hydrocarbons, PCB congeners (e.g., Aroclor mixes), essential oils, semivolatiles. Column specifically tested for low-bleed performance. Temperature range:…
-
Ultra Carbamate Columns
RestekRestek chemists developed the Ultra Carbamate column specifically for carbamates analysis. The unique packing separates 10 target carbamates in just 5 minutes with an 8 minute total cycle time. The column is compatible with fluorescence or LC-MS detection.* An Ultra Carbamate column can process as…