  • DB-5ms

    Agilent Technologies

    Phenyl Arylene polymer virtually equivalent to a (5%-Phenyl)-methylpolysiloxane Non-polar Very low bleed, suitable for GC/MS Exhibits inertness to active compounds Temperature limits are -60° to 325°/350°C Improved signal-to-noise ration for increased sensitivity and mass…

  • ZORBAX Eclipse XDB Columns

    Agilent Technologies

    Agilent ZORBAX Eclipse XDB columns – C18, C8, Phenyl and CN – provide four bonded phase choices for method development optimization. These columns provide good peak shape over a wide pH range (2-9) for additional method development flexibility with one family of columns. Eclipse XDB…

  • SampliQ QuEChERS Kits

    Agilent Technologies

    Extraction salts are pre-measured and provided in anhydrous packets, so you can conveniently add them after the acetonitrile and improve results Kits available with ceramic homogenizers to facilitate sample homogenization and to break up salt agglomerates more efficiently than shaking by hand;…

  • Capillary Column Ferrules

    Agilent Technologies

    Capillary ferrules are packaged in dial packs which deliver one ferrule at a time, keeping the others clean and ready for use. The dial packaging has been tested to ensure no out gassing of contaminants, including phthalates. *These ferrules are recommended for use with Agilent GC/MS…

  • Press-Fit Capillary Column Connectors

    Agilent Technologies

    In the past it was necessary to use Press-fit connectors with specific dimensions to connect columns of those dimensions. Modern Press-fit connectors are “laser-milled” to provide highly reproducible taper angles throughout the length of the Press-fit insuring an excellent seal. Now the…

  • DB-624

    Agilent Technologies

    Specifically designed for the analysis of volatile priority pollutants No cryogenics needed for U.S. EPA Method 502.2 Excellent for U.S. EPA Methods: 501.3, 502.2, 503.1, 524.2, 601, 602, 8010, 8015, 8020, 8240 and 8260 Exhibits inertness to active compounds Bonded and cross-linked Solvent…

  • HP-1

    Agilent Technologies

    100% Dimethylpolysiloxane Industry standard general purpose column Non-polar Wide range of applications Superior performance of low molecular weight alcohols High temperature limit Bonded and cross-linked Solvent rinsable Wide range of column dimensions …

  • ZORBAX NH2 Columns

    Agilent Technologies

    Amino-propyl silane phase bonded to ZORBAX SIL Used for normal phase and weak anion-exchange, and reversed-phase  HPLC of polar compounds Vitamins A and D are separated in the normal-phase mode Carbohydrates and sugars are separated in the reversed-phase mode …

  • DB-5

    Agilent Technologies

    (5%-Phenyl)-methylpolysiloxane Non-polar General purpose column Wide range of applications Low bleed High temperature limit: -60° to 325/350°C* Bonded and cross-linked Solvent rinsable Wide range of column dimensions available Equivalent to USP…

  • ZORBAX Rapid Resolution High Definition Columns

    Agilent Technologies

    For use up to 1200 bar ZORBAX Rapid Resolution High Definition (RRHD) columns are an expansion of the ZORBAX 1.8 µm particle column line. The new RRHD columns use improved packing processes to achieve stability up to 1200 bar for use with the Agilent 1290 Infinity LC. The RRHD 1.8 µm columns are…

  • ZORBAX 80 Extend-C18

    Agilent Technologies

    High efficiency and long life at high pH — up to pH 11.5 Unique bidentate bonding and double endcapping provides high pH stability More efficiency and better peak shape than polymer-based columns Improve retention, resolution and peak shape of basic compounds High sensitivity for GC/MS…

  • ZORBAX Capillary and Nano Columns

    Agilent Technologies

    Highest sensitivity for your smallest sample sizes Compatible with all LC/MS interfaces Internal diameters of 0.5, 0.3, 0.1, and 0.075 mm Packings/phases for both small and large molecules (80Å and 300Å pore sizes, respectively) Ideal for 1-D and 2-D (proteomics)…

  • Prep LC Columns

    Agilent Technologies

    High loadability for maximum sample purification Easy scalability from 4.6 mm ID up to 50 mm ID for rapid method development High throughput 21.2 mm ID cartridges for fast purification Exceptional column stability and loadability up to pH 10 Agilent Prep LC columns are…

  • SampliQ Silica C18 ODS SPE Cartridges

    Agilent Technologies

    Reversed Phase (Non-Polar) 24% carbon loading Silica-based particles reduce pressure drop and increase flow reproducibility Average particle size of 45 µm and pore diameter of 60Å to reduce pressure drop and increase flow reproducibility Agilent’s trifunctional…

  • ZORBAX Rapid Resolution 3.5 m Eclipse Columns

    Agilent Technologies

    Reduce analysis time and solvent usage and increase sample throughput High efficiency in short and ultra-short column lengths Available in analytical (4.6 mm) and narrow-bore (2.1 mm) ID Comparable lifetime to 5 µm columns Agilent ZORBAX Rapid Resolution columns, with a 3.5 µm particle size,…

  • ZORBAX Eclipse Plus

    Agilent Technologies

    ZORBAX Eclipse Plus HPLC columns are the ideal first choice for method development of all samples. Available in C18, C8, Phenyl Hexyl and PAH.

  • Deactivated Fused Silica Tubing

    Agilent Technologies

    Deactivated tubing can be used as retention gaps, guard columns, or transfer lines. Our standard deactivation process is a phenyl methyl deactivation — the preferred choice for most applications due to its inertness and robustness.

  • Chiradex Chiral Columns

    Agilent Technologies

    For routine separation of enantiomers Available as ChiraDex cartridge columns Novel manufacturing process bonds ß-cyclodextrin to spherical 5 µm silica gel by means of a chemical spacer Enantiomeric separations have been achieved with ChiraDex using simple nonchiral solvent…

  • ZORBAX MicroBore (1.0 mm ID) StableBond

    Agilent Technologies

    High sensitivity for small sample sizes Compatible with LC/MS interfaces Wide variety of bonded phases MicroBore (1 mm ID) columns are often a good choice when sample sizes are limited. They can improve detection limits 5 times over 2.1 mm ID columns when the same sample mass is used. This…

  • ZORBAX Eclipse XDB-CN Columns

    Agilent Technologies

    Made from highly pure Rx-SIL Excellent choice for normal phase applications with basic compounds Equilibrates more rapidly than ZORBAX Rx-SIL and is used for many of the same normalphase applications *These columns ship containing reversed phase solvents. Flush with isopropanol…

  • DB-ALC1 And DB-ALC2

    Agilent Technologies

    Meets EN14110 standard Reliable blood alcohol analysis Optimized primary and confirmation column pair for U.S. blood alcohol analysis Faster GC run times Improved resolution of key ethanol/acetone peaks Available in 0.32 and 0.53 mm ID Bonded and cross-linked …

  • Column Nuts

    Agilent Technologies

    Agilent MS interface column nuts (or transfer line nuts) are manufactured from a softer metal than the transfer line interface. This is to prevent stripping of the transfer line threads and costly repairs. Add a few MS interface column nuts to your next order and keep spares on hand.

  • ZORBAX 80 Stablebond

    Agilent Technologies

    RR: Rapid Resolution 3.5 µm RRHT: Rapid Resolution HT 1.8 µm

  • SampliQ Polymer OPT SPE Cartridges

    Agilent Technologies

    Most versatile SPE option Reversed phase retention mechanism simplifies method development and compatibility for both GC and LC separations Unlike silica-based phases, OPT cartridges yield the same exacting results if they inadvertently dry out during the conditioning stage …

  • SampliQ Polymer WCX SPE Cartridges

    Agilent Technologies

    Weak Cation Exchange Exhibits both cation exchange and reversed phase behavior Wide pH range: can be ionized or neutral depending on pH of buffer solution WCX resin retains basic/cationic, neutral and strong bases Agilent SampliQ WCX is designed to retain and release strong…

  • SampliQ Florisil PR SPE Cartridges

    Agilent Technologies

    Generally used to retain polar analytes Solvent retention generally decreases as solvent becomes more polar A great option when more generally-used sorbents, such as C18, don’t perform specifically enough for your particular application SampliQ* Florisil PR is a selective…

  • DB-502.2

    Agilent Technologies

    Available in 105 meters for volatiles analyses Excellent peak shape Bonded and cross-linked Solvent rinsable Similar Phases: Rtx-502.2, VOCOL, HP-VOC

  • ZORBAX Solvent Saver Columns 80 Eclipse XDB

    Agilent Technologies

    Provide 60% reduction in mobile phase usage and waste generation compared to a 4.6 mm ID column Provide 2- to 3-fold signal-to-noise (S/N ratio) improvement Deliver optimal LC/MS performance at intermediate flow rates Can be used with most conventional LC instrument configurations…

  • Nucleosil Reversed-Phase Columns

    Agilent Technologies

    Nucleosil is a spherical porous “sil-gel” type silica packing material from Machery/Nagel. Agilent packs Nucleosil columns using tight ISO-regulated production control procedures to guarantee consistent quality. Nucleosil 100-5, C18 is used for non-polar to moderately polar compounds in…

  • ZORBAX 300 Stablebond

    Agilent Technologies

    RR: Rapid Resolution 3.5 µm

  • ZORBAX Rapid Resolution 3.5 m StableBond Columns

    Agilent Technologies

    RR: Rapid Resolution 3.5 m

  • DB-23

    Agilent Technologies

    50%-Cyanopropyl)-methylpolysiloxane High polarity Designed for separation of fatty acid methyl esters (FAMEs) Excellent resolution for cis- and trans-isomers Bonded and cross-linked Solvent rinsable Replaces HP-23 Close equivalent to USP Phase G5 Similar…