Columns

Compare Tool

Select up to 3 products

1 - 32 of 241
Sort
View
Show
  • Capillary Column Ferrules

    Agilent Technologies

    Capillary ferrules are packaged in dial packs which deliver one ferrule at a time, keeping the others clean and ready for use. The dial packaging has been tested to ensure no out gassing of contaminants, including phthalates. *These ferrules are recommended for use with Agilent GC/MS…

  • SampliQ QuEChERS Kits

    Agilent Technologies

    Extraction salts are pre-measured and provided in anhydrous packets, so you can conveniently add them after the acetonitrile and improve results Kits available with ceramic homogenizers to facilitate sample homogenization and to break up salt agglomerates more efficiently than shaking by hand;…

  • DB-5ms

    Agilent Technologies

    Phenyl Arylene polymer virtually equivalent to a (5%-Phenyl)-methylpolysiloxane Non-polar Very low bleed, suitable for GC/MS Exhibits inertness to active compounds Temperature limits are -60° to 325°/350°C Improved signal-to-noise ration for increased sensitivity and mass…

  • DB-624

    Agilent Technologies

    Specifically designed for the analysis of volatile priority pollutants No cryogenics needed for U.S. EPA Method 502.2 Excellent for U.S. EPA Methods: 501.3, 502.2, 503.1, 524.2, 601, 602, 8010, 8015, 8020, 8240 and 8260 Exhibits inertness to active compounds Bonded and cross-linked Solvent…

  • HP-5ms

    Agilent Technologies

    Meets EN14331 Standards (5%-Phenyl)-methylpolysiloxane Non-polar Very low bleed, suitable for GC/MS Exhibits inertness to active compounds Temperature limits are -60° to 325°/350°C Improved signal-to-noise ration for increased sensitivity and mass spectral integrity Bonded and cross-linked…

  • ZORBAX Eclipse XDB Columns

    Agilent Technologies

    Agilent ZORBAX Eclipse XDB columns – C18, C8, Phenyl and CN – provide four bonded phase choices for method development optimization. These columns provide good peak shape over a wide pH range (2-9) for additional method development flexibility with one family of columns. Eclipse XDB…

  • Column Nuts

    Agilent Technologies

    Agilent MS interface column nuts (or transfer line nuts) are manufactured from a softer metal than the transfer line interface. This is to prevent stripping of the transfer line threads and costly repairs. Add a few MS interface column nuts to your next order and keep spares on hand.

  • Nucleosil Reversed-Phase Columns

    Agilent Technologies

    Nucleosil is a spherical porous “sil-gel” type silica packing material from Machery/Nagel. Agilent packs Nucleosil columns using tight ISO-regulated production control procedures to guarantee consistent quality. Nucleosil 100-5, C18 is used for non-polar to moderately polar compounds in…

  • DX-1 And DX-4

    Agilent Technologies

    DX-1: 90% Dimethylpolysiloxane - 10% Polyethylene Glycol DX-4: 15% Dimethylpolysiloxane - 85% Polyethylene Glycol Because DX series GC columns are not bonded and cross-linked, we do not recommend solvent rinsing.

  • Lichrospher Reversed-Phase Cartridge Columns

    Agilent Technologies

    LiChrospher silica columns are made with spherical “sil-gel” type porous silica particles LiChrospher 60 RP-select B starts with 60Å pore size silica optimized for symmetrical peak shapes of basic compounds. LiChrospher 100Å is offered in both C8 and C18, as well as an…

  • ZORBAX Rx-C8

    Agilent Technologies

    Rx-C8 is the same product as SB-C8 *RR: Rapid Resolution 3.5 µm

  • DB-Wax

    Agilent Technologies

    GC capillary columns are typically wound on 7 inch cages that fit into standard-sized GCs like the 6890. The 6850 GC has a smaller oven which requires the use of columns wound on a smaller cage diameter. Polyethylene glycol (PEG) Close equivalent to USP Phase G16 High polarity …

  • HP-5

    Agilent Technologies

    (5%-Phenyl)-methylpolysiloxane Non-polar Wide range of applications High temperature limits: -60° to 325°C isothermally, -60° to 350°C programmed. -60° to 300°C isothermally, -60° to 320°C programmed for 0.53 mm columns -60° to 260°/280°C for =2.0 µm films Bonded and cross-linked Solvent…

  • Amino Acid Standards

    Agilent Technologies

    *Consider shelf-life and buy limited quantities, 2714H95 ships as 1 g vials

  • DB-17

    Agilent Technologies

    (50%-Phenyl)-methylpolysiloxane Midpolarity slightly more polar than HP-50+ Suitable for confirmational analyses Bonded and cross-linked Solvent rinsable Temperature limits are 40° to 260/280°C or 40° to 280/300°C Equivalent to USP Phase G3 HP-50+, Rtx-50, CP-Sil 24 CB, 007-17(MPS-50),…

  • ZORBAX 80 Stablebond

    Agilent Technologies

    RR: Rapid Resolution 3.5 µm RRHT: Rapid Resolution HT 1.8 µm

  • Bio Ion Exchange (IEX) HPLC Columns 

    Agilent Technologies

    Bio IEX: High-res, charge-based analytical separations Agilent Bio Ion Exchange HPLC columns are packed with polymeric, nonporous, ion exchange particles. Bio Ion Exchange Columns are designed for high resolution, high recovery and highly efficient separations of peptides, oligonucleotides and…

  • ZORBAX Ion Exchange Columns - Sax And Scx

    Agilent Technologies

    ZORBAX SAX and 300SCX columns are based on rugged Zorbax silica Stable from pH 2-7 Provides high efficiency, rapid separations Compatible with organic mobile phase modifiers ZORBAX Bio-SCX Series II for 2-D separations Zorbax strong ion-exchange columns are available as both Strong Anion…

  • ZORBAX Capillary and Nano Columns

    Agilent Technologies

    Highest sensitivity for your smallest sample sizes Compatible with all LC/MS interfaces Internal diameters of 0.5, 0.3, 0.1, and 0.075 mm Packings/phases for both small and large molecules (80Å and 300Å pore sizes, respectively) Ideal for 1-D and 2-D (proteomics)…

  • DB-5 And DB-5ms

    Agilent Technologies

    GC capillary columns are typically wound on 7 inch cages that fit into standard-sized GCs like the 6890. The 6850 GC has a smaller oven which requires the use of columns wound on a smaller cage diameter. DB-5 (2713R99, T86, T94 and V89) (5%-Phenyl)-methylpolysiloxane Non-polar …

  • ZORBAX Rapid Resolution High Definition Columns

    Agilent Technologies

    For use up to 1200 bar ZORBAX Rapid Resolution High Definition (RRHD) columns are an expansion of the ZORBAX 1.8 µm particle column line. The new RRHD columns use improved packing processes to achieve stability up to 1200 bar for use with the Agilent 1290 Infinity LC. The RRHD 1.8 µm columns are…

  • HP-5ms Ultra Inert

    Agilent Technologies

    Agilent J&W HP-5ms Ultra Inert is specifically tested for inertness for active compounds, including acidic and basic compounds, to meet the worldwide drive for lower detection levels. With very low bleed characteristics, bonded and cross-linked HP-5ms Ultra Inert is solvent rinsable and ideal…

  • Pursuit XRs HPLC Columns

    Agilent Technologies

    For performance in analytical R&D, QC and preparative applications. Combining high ligand density with a 100Å pore size, high surface area silica, Pursuit XRs columns are designed to increase productivity, as they offer maximum loadability, excellent stability and easy scalability while…

  • FID and NPD Jets

    Agilent Technologies

  • ZORBAX Rx-Sil Columns

    Agilent Technologies

    Made from highly pure (>99.995%) porous silica microspheres (pore size is the space between the solid silica microparticles) Stronger than other silica types Less acidic than ZORBAX-SIL, lower metal content Low acidity and low metal content make ZORBAX Rx-SIL ideal for…

  • DB-VRX

    Agilent Technologies

    Unique selectivity engineered for optimum resolution of volatiles analysis: U.S. EPA Methods 502.2, 524.2 and 8260 0.45 mm ID columns provide more plates per meter compared to 0.53 mm ID columns for the fewest coelutions for GC method (an industry first)** No subambient cooling required to…

  • Straight Ferrules

    Agilent Technologies

  • SampliQ Silica SPE Cartridges

    Agilent Technologies

    Normal Phase (Polar) Average particle size of 45 µm and pore diameter of 60Å to reduce pressure drop and increase flow reproducibility Agilent’s trifunctional bonding process provides more stability over monomeric bonding Manufactured to Agilent’s rigorous quality standards…

  • ZORBAX Eclipse Plus

    Agilent Technologies

    ZORBAX Eclipse Plus HPLC columns are the ideal first choice for method development of all samples. Available in C18, C8, Phenyl Hexyl and PAH.

  • DB-1701p

    Agilent Technologies

    Low/midpolarity Exact replacement of HP-PAS1701 Specifically designed and processed for the analysis of organochlorine pesticides ECD tested to assure minimal pesticide breakdown and low ECD bleed Bonded and cross-linked Solvent rinsable Similar Phases: SPB-1701,…

  • Carbowax 20m And HP-20m

    Agilent Technologies

    Polyethylene glycol, MW 20,000 Equivalent to USP Phase G16 Similar Phases: DB-WAX, HP-INNOWax, DB-WAXetr Because the Carbowax 20M and the HP-20M are not bonded or cross-linked, we do not recommend solvent rinsing. DB-WAX is the recommended bonded alternate for the HP-20M.

  • ZORBAX NH2 Columns

    Agilent Technologies

    Amino-propyl silane phase bonded to ZORBAX SIL Used for normal phase and weak anion-exchange, and reversed-phase  HPLC of polar compounds Vitamins A and D are separated in the normal-phase mode Carbohydrates and sugars are separated in the reversed-phase mode …

Compare Tool

Select up to 3 products

Please Log In

Don't have an Account? Create one now.