Agilent Technologies

Columns, Agilent Technologies

Compare Tool

Select up to 3 products

1 - 32 of 244
Sort
View
Show
  • ZORBAX Eclipse XDB Columns

    Agilent Technologies

    Agilent ZORBAX Eclipse XDB columns – C18, C8, Phenyl and CN – provide four bonded phase choices for method development optimization. These columns provide good peak shape over a wide pH range (2-9) for additional method development flexibility with one family of columns. Eclipse XDB…

  • DB-1701

    Agilent Technologies

    (14%-Cyanopropyl-phenyl)-methylpolysiloxane Low/midpolarity Bonded and cross-linked Solvent rinsable Exact replacement for HP-1701 Similar Phases: DB-1701: SPB-1701, CP-Sil 19 CB, Rtx-1701, BP-10, OV-1701, 007-1701, ZB-170

  • Capillary Column Ferrules

    Agilent Technologies

    Capillary ferrules are packaged in dial packs which deliver one ferrule at a time, keeping the others clean and ready for use. The dial packaging has been tested to ensure no out gassing of contaminants, including phthalates. *These ferrules are recommended for use with Agilent GC/MS…

  • HP-Plot Q

    Agilent Technologies

    Bonded polystyrene-divinylbenzene based column A PLOT column with polarity between Porapak-Q and Porapak-N Column for C1 to C3 isomers and Alkanes to C12, CO2 , methane, air/CO, oxygenated compounds, sulfur compounds and solvents A PLOT column to replace packed…

  • HP-Innowax

    Agilent Technologies

    Meets EN1410 and EN14331 Standards Polyethylene glycol (PEG) Close equivalent to USP Phase G16 High polarity Highest upper temperature limits of bonded PEG phases (260°/270°C) Column-to-column repeatability Bonded and cross-linked Solvent rinsable …

  • DB-ALC1 And DB-ALC2

    Agilent Technologies

    Meets EN14110 standard Reliable blood alcohol analysis Optimized primary and confirmation column pair for U.S. blood alcohol analysis Faster GC run times Improved resolution of key ethanol/acetone peaks Available in 0.32 and 0.53 mm ID Bonded and cross-linked …

  • GS-Gaspro

    Agilent Technologies

    Bonded PLOT column technology Suitable for light hydrocarbons and sulfur gas Retention stability not affected by water Separates CO and CO2 on a single column Ideal PLOT column for CG/MS - no particles Temperature limits: -80° to 260°/300°C …

  • SampliQ QuEChERS Kits

    Agilent Technologies

    Extraction salts are pre-measured and provided in anhydrous packets, so you can conveniently add them after the acetonitrile and improve results Kits available with ceramic homogenizers to facilitate sample homogenization and to break up salt agglomerates more efficiently than shaking by hand;…

  • DB-PS1 15m, 0.53mm, 0.15um

    Agilent Technologies

    Excellent inertness Virtually unbreakable Available in a wide variety of stationary phases Bonded and cross-linked Ideal for high temperature analysis and process applications Our asy to handle DB-ProSteel metal columns are deactivated with a new formula (this is not glass lined steel)…

  • GS-Alumina

    Agilent Technologies

    Most “polar” Alumina phase Aluminum oxide with proprietary deactivation Excellent general use column for light hydrocarbon analysis: C1 to C8 hydrocarbon isomers Separates C1-C4 saturated and unsaturated hydrocarbons Best for resolving cyclopropane from propylene …

  • DB-210

    Agilent Technologies

    (50%-Trifluoropropyl)-methylpolysiloxane High polarity Excellent for U.S. EPA Methods 8140 and 609 Bonded and cross-linked Solvent rinsable Exact replacement of HP-210 Close equivalent to USP Phase G6 Similar Phases: SP-2401

  • DB-225ms

    Agilent Technologies

    Virtually equivalent to (50%-Cyanopropylphenyl)-methylpolysiloxane Mid/high polarity Excellent for separations of cis- and trans-fatty acid methyl esters (FAMEs) Low bleed Bonded and cross-linked Solvent rinsable Close equivalent to USP Phase G7 Similar Phases:…

  • DB-1

    Agilent Technologies

    GC capillary columns are typically wound on 7 inch cages that fit into standard-sized GCs like the 6890. The 6850 GC has a smaller oven which requires the use of columns wound on a smaller cage diameter. 100% Dimethylpolysiloxane Non-polar Excellent general purpose column …

  • DB-5

    Agilent Technologies

    (5%-Phenyl)-methylpolysiloxane Non-polar General purpose column Wide range of applications Low bleed High temperature limit: -60° to 325/350°C* Bonded and cross-linked Solvent rinsable Wide range of column dimensions available Equivalent to USP…

  • DB-Wax

    Agilent Technologies

    GC capillary columns are typically wound on 7 inch cages that fit into standard-sized GCs like the 6890. The 6850 GC has a smaller oven which requires the use of columns wound on a smaller cage diameter. Polyethylene glycol (PEG) Close equivalent to USP Phase G16 High polarity …

  • DB-624

    Agilent Technologies

    Specifically designed for the analysis of volatile priority pollutants No cryogenics needed for U.S. EPA Method 502.2 Excellent for U.S. EPA Methods: 501.3, 502.2, 503.1, 524.2, 601, 602, 8010, 8015, 8020, 8240 and 8260 Exhibits inertness to active compounds Bonded and cross-linked Solvent…

  • Ultra 2

    Agilent Technologies

    GC capillary columns are typically wound on 7 inch cages that fit into standard-sized GCs like the 6890. The 6850 GC has a smaller oven which requires the use of columns wound on a smaller cage diameter. Non-polar (5%-Phenyl)-methylpolysiloxane Equivalent to HP-5 with tighter…

  • Polaris Columns

    Agilent Technologies

    In areas like drug discovery where target compounds are increasingly polar, it is critical to have a reversed-phase column that performs well under aqueous conditions. Retention is critical, but cannot come with troublesome secondary interactions. From the collapse-resistant pore structure of…

  • ZORBAX PSM GPC-Sec Columns

    Agilent Technologies

    Agilent ZORBAX PSM Size Exclusion Columns can be used for molecular size separations on most synthetic and natural polymers. The ZORBAX PSM columns are packed with small (5 µm) porous silica microspheres (PSM) and are available in two versions. The deactivated version has been silanized for…

  • ZORBAX 80 Stablebond

    Agilent Technologies

    RR: Rapid Resolution 3.5 µm RRHT: Rapid Resolution HT 1.8 µm

  • HP-5

    Agilent Technologies

    (5%-Phenyl)-methylpolysiloxane Non-polar Wide range of applications High temperature limits: -60° to 325°C isothermally, -60° to 350°C programmed. -60° to 300°C isothermally, -60° to 320°C programmed for 0.53 mm columns -60° to 260°/280°C for =2.0 µm films Bonded and cross-linked Solvent…

  • Eclipse Plus C18 4.6X150mm 5um

    Agilent Technologies

  • PoraPLOT Q

    Agilent Technologies

    PoraPLOT Q is a popular porous polymer PLOT stationary phase recommended for applications that analyze polar and apolar volatile compounds.

  • DB-Wax

    Agilent Technologies

    Polyethylene glycol (PEG) Close equivalent to USP Phase G16 High polarity Lower temperature limit of 20°C is lowest of any bonded PEG phase; improves resolution of low boiling point analytes Column-to-column repeatability Bonded and cross-linked Solvent rinsable …

  • ZORBAX Rapid Resolution High Throughput 1.8 M Columns

    Agilent Technologies

    High pressure (600 bar) columns for ultra high speed or maximum resolution analyses with Rapid Resolution HT columns packed with totally porous, 1.8 µm packings Carefully engineered particles deliver maximum resolution at 25% less pressure than other sub 2-micron materials Reduce…

  • ZORBAX Rapid Resolution High Definition Columns

    Agilent Technologies

    For use up to 1200 bar ZORBAX Rapid Resolution High Definition (RRHD) columns are an expansion of the ZORBAX 1.8 µm particle column line. The new RRHD columns use improved packing processes to achieve stability up to 1200 bar for use with the Agilent 1290 Infinity LC. The RRHD 1.8 µm columns are…

  • ZORBAX Eclipse Amino Acid Analysis (AAA) Columns

    Agilent Technologies

    High resolution and rapid analysis of 24 amino acids Use tested for amino acid analysis Uses well known OPA and FMOC precolumn derivatization chemistry Easily automated using a detailed online, derivatization protocol available for use with Agilent 1100/1200 Autosampler The…

  • HP-Ms

    Agilent Technologies

    GC capillary columns are typically wound on 7 inch cages that fit into standard-sized GCs like the 6890. The 6850 GC has a smaller oven which requires the use of columns wound on a smaller cage diameter. (5%-Phenyl)-methylpolysiloxane Identical selectivity to HP-5 Non-polar …

  • Column Nuts

    Agilent Technologies

    Agilent MS interface column nuts (or transfer line nuts) are manufactured from a softer metal than the transfer line interface. This is to prevent stripping of the transfer line threads and costly repairs. Add a few MS interface column nuts to your next order and keep spares on hand.

  • J&W DB-1ms Ultra Inert Capillary GC Columns

    Agilent Technologies

    DB-1ms is an excellent general-purpose GC column and ideal for GC/MS of active analytes commonly found in drug screening and environmental analyses. The Ultra Inert 1ms GC columns set the new industry standards for consistent column inertness and exceptionally low column bleed. These columns…

  • HP-5ms

    Agilent Technologies

    Meets EN14331 Standards (5%-Phenyl)-methylpolysiloxane Non-polar Very low bleed, suitable for GC/MS Exhibits inertness to active compounds Temperature limits are -60° to 325°/350°C Improved signal-to-noise ration for increased sensitivity and mass spectral integrity Bonded and cross-linked…

  • CP-Wax 52 CB Capillary Columns

    Agilent Technologies

    Agilent J&W CP-Wax 52 CB has a lower minimum temperature and a higher maximum temperature than non-bonded polyethylene glycol (PEG) columns due to extensive cross linking, delivering higher resolution of low-boiling-point analytes. With guaranteed reproducibility and excellent temperature…

Compare Tool

Select up to 3 products

Please Log In

Don't have an Account? Create one now.