Agilent Technologies

Columns, Agilent Technologies

Compare Tool

Select up to 3 products

1 - 32 of 244
Sort
View
Show
  • ZORBAX Eclipse XDB Columns

    Agilent Technologies

    Agilent ZORBAX Eclipse XDB columns – C18, C8, Phenyl and CN – provide four bonded phase choices for method development optimization. These columns provide good peak shape over a wide pH range (2-9) for additional method development flexibility with one family of columns. Eclipse XDB…

  • Capillary Column Ferrules

    Agilent Technologies

    Capillary ferrules are packaged in dial packs which deliver one ferrule at a time, keeping the others clean and ready for use. The dial packaging has been tested to ensure no out gassing of contaminants, including phthalates. *These ferrules are recommended for use with Agilent GC/MS…

  • ZORBAX NH2 Columns

    Agilent Technologies

    Amino-propyl silane phase bonded to ZORBAX SIL Used for normal phase and weak anion-exchange, and reversed-phase  HPLC of polar compounds Vitamins A and D are separated in the normal-phase mode Carbohydrates and sugars are separated in the reversed-phase mode …

  • Column Nuts

    Agilent Technologies

    Agilent MS interface column nuts (or transfer line nuts) are manufactured from a softer metal than the transfer line interface. This is to prevent stripping of the transfer line threads and costly repairs. Add a few MS interface column nuts to your next order and keep spares on hand.

  • DB-1701

    Agilent Technologies

    (14%-Cyanopropyl-phenyl)-methylpolysiloxane Low/midpolarity Bonded and cross-linked Solvent rinsable Exact replacement for HP-1701 Similar Phases: DB-1701: SPB-1701, CP-Sil 19 CB, Rtx-1701, BP-10, OV-1701, 007-1701, ZB-170

  • DB-Wax

    Agilent Technologies

    Polyethylene glycol (PEG) Close equivalent to USP Phase G16 High polarity Lower temperature limit of 20°C is lowest of any bonded PEG phase; improves resolution of low boiling point analytes Column-to-column repeatability Bonded and cross-linked Solvent rinsable …

  • ZORBAX Rx-C8

    Agilent Technologies

    Rx-C8 is the same product as SB-C8 *RR: Rapid Resolution 3.5 µm

  • HP-Innowax

    Agilent Technologies

    Meets EN1410 and EN14331 Standards Polyethylene glycol (PEG) Close equivalent to USP Phase G16 High polarity Highest upper temperature limits of bonded PEG phases (260°/270°C) Column-to-column repeatability Bonded and cross-linked Solvent rinsable …

  • ZORBAX Eclipse Plus

    Agilent Technologies

    ZORBAX Eclipse Plus HPLC columns are the ideal first choice for method development of all samples. Available in C18, C8, Phenyl Hexyl and PAH.

  • DB-Petro 100m, .25mm, 0.5um, 5"Cage

    Agilent Technologies

    GC capillary columns are typically wound on 7 inch cages that fit into standard-sized GCs like the 6890. The 6850 GC has a smaller oven which requires the use of columns wound on a smaller cage diameter. 100% Dimethylpolysiloxane Configured for the analysis of petroleum process…

  • HP-Plot Q

    Agilent Technologies

    Bonded polystyrene-divinylbenzene based column A PLOT column with polarity between Porapak-Q and Porapak-N Column for C1 to C3 isomers and Alkanes to C12, CO2 , methane, air/CO, oxygenated compounds, sulfur compounds and solvents A PLOT column to replace packed…

  • DB-Wax

    Agilent Technologies

    GC capillary columns are typically wound on 7 inch cages that fit into standard-sized GCs like the 6890. The 6850 GC has a smaller oven which requires the use of columns wound on a smaller cage diameter. Polyethylene glycol (PEG) Close equivalent to USP Phase G16 High polarity …

  • HP-1ms

    Agilent Technologies

    100% Dimethylpolysiloxane Identical selectivity to HP-1 Non-polar Low bleed characteristics General purpose column Improved signal-to-noise ratio for better sensitivity and mass spectral integrity Bonded and cross-linked Solvent rinsable Temperature range:…

  • CP-Wax 52 CB Capillary Columns

    Agilent Technologies

    Agilent J&W CP-Wax 52 CB has a lower minimum temperature and a higher maximum temperature than non-bonded polyethylene glycol (PEG) columns due to extensive cross linking, delivering higher resolution of low-boiling-point analytes. With guaranteed reproducibility and excellent temperature…

  • ZORBAX 80 Stablebond

    Agilent Technologies

    RR: Rapid Resolution 3.5 µm RRHT: Rapid Resolution HT 1.8 µm

  • HP-101

    Agilent Technologies

    100% Dimethylpolysiloxane Temperature limits: -60 to 280°C Similar Phases: OV-101, SP 200, DB-1, HP-1 Because HP-101 columns are not bonded or cross-linked, we do not recommend solvent rinsing.

  • DB-5

    Agilent Technologies

    (5%-Phenyl)-methylpolysiloxane Non-polar General purpose column Wide range of applications Low bleed High temperature limit: -60° to 325/350°C* Bonded and cross-linked Solvent rinsable Wide range of column dimensions available Equivalent to USP…

  • HP-5

    Agilent Technologies

    GC capillary columns are typically wound on 7 inch cages that fit into standard-sized GCs like the 6890. The 6850 GC has a smaller oven which requires the use of columns wound on a smaller cage diameter. (5%-Phenyl)-methylpolysiloxane Non-polar Excellent general purpose column …

  • SampliQ Silica C8/Si-SCX Mixed Mode SPE Cartridges

    Agilent Technologies

    Generally used to retain polar analytes Solvent retention generally decreases as solvent becomes more polar A great option when more generally-used sorbents, such as C18, don’t perform specifically enough for your particular application The SampliQ Mixed-Mode Reversed-Phase SPE…

  • ZORBAX Rapid Resolution 3.5 m Eclipse Columns

    Agilent Technologies

    Reduce analysis time and solvent usage and increase sample throughput High efficiency in short and ultra-short column lengths Available in analytical (4.6 mm) and narrow-bore (2.1 mm) ID Comparable lifetime to 5 µm columns Agilent ZORBAX Rapid Resolution columns, with a 3.5 µm particle size,…

  • ZORBAX PrepHT Columns

    Agilent Technologies

    Easy scale-up from analytical to preparative scale with ZORBAX phases Fast preparative separations, up to 2000 mg 5 to 7 µm particles for high efficiency and high yield Easy to install; finger tight connections seal up to 5000 psi/350 bar High purity, high recovery and high throughput can be…

  • Eclipse Plus Phenyl-Hexyl, 4.6X150mm, 5um

    Agilent Technologies

  • DB-1

    Agilent Technologies

    GC capillary columns are typically wound on 7 inch cages that fit into standard-sized GCs like the 6890. The 6850 GC has a smaller oven which requires the use of columns wound on a smaller cage diameter. 100% Dimethylpolysiloxane Non-polar Excellent general purpose column …

  • SampliQ QuEChERS Kits

    Agilent Technologies

    Extraction salts are pre-measured and provided in anhydrous packets, so you can conveniently add them after the acetonitrile and improve results Kits available with ceramic homogenizers to facilitate sample homogenization and to break up salt agglomerates more efficiently than shaking by hand;…

  • J&W DB-1ms Ultra Inert Capillary GC Columns

    Agilent Technologies

    DB-1ms is an excellent general-purpose GC column and ideal for GC/MS of active analytes commonly found in drug screening and environmental analyses. The Ultra Inert 1ms GC columns set the new industry standards for consistent column inertness and exceptionally low column bleed. These columns…

  • Dbht-Simd 5m, 0.53mm, 0.15um

    Agilent Technologies

    100% Dimethylpolysiloxane “Boiling point” phase for high temperature simulated distillation Durable stainless steel tubing 430°C upper temperature limit Distillation range of C6 to C110 Low bleed - even at 430°C Bonded and cross-linked Solvent…

  • DB-FFAP 30m, .32mm, .25um, 5" Cage

    Agilent Technologies

    GC capillary columns are typically wound on 7 inch cages that fit into standard-sized GCs like the 6890. The 6850 GC has a smaller oven which requires the use of columns wound on a smaller cage diameter. Nitroterephthalic acid modified polyethylene glycol High polarity Temperature…

  • HP-Fast GC Residual Solvent, 5" Cage

    Agilent Technologies

    GC capillary columns are typically wound on 7 inch cages that fit into standard-sized GCs like the 6890. The 6850 GC has a smaller oven which requires the use of columns wound on a smaller cage diameter. Equivalent to USP Phase G43 Thinner film reduces run time by 2.5 times and…

  • HP-Pona

    Agilent Technologies

    GC capillary columns are typically wound on 7 inch cages that fit into standard-sized GCs like the 6890. The 6850 GC has a smaller oven which requires the use of columns wound on a smaller cage diameter. 100% Dimethylpolysiloxane Configured for the analysis of petroleum process…

  • DB-2887 10m, 0.53mm, 3.00um

    Agilent Technologies

    100% Dimethylpolysiloxane Specifically designed for simulated distillation using ASTM Method D2887 Rapid conditioning, fast run time and low bleed when compared to packed columns Bonded and cross-linked Solvent rinsable Similar Phases: HP-1, Petrocol EX2887, MXT-2887, MXT-1

  • ZORBAX Rapid Resolution High Definition Columns

    Agilent Technologies

    For use up to 1200 bar ZORBAX Rapid Resolution High Definition (RRHD) columns are an expansion of the ZORBAX 1.8 µm particle column line. The new RRHD columns use improved packing processes to achieve stability up to 1200 bar for use with the Agilent 1290 Infinity LC. The RRHD 1.8 µm columns are…

  • DB-1ms

    Agilent Technologies

    100% Dimethylpolysiloxane Identical selectivity to DB-1 Non-polar Very low bleed characteristics, ideal for GC/MS Improved acid performance compared to standard 100% Dimethylpolysiloxane columns Improved signal-to-noise ratio for better sensitivity and mass spectral integrity …

Compare Tool

Select up to 3 products

Please Log In

Don't have an Account? Create one now.