Agilent Technologies

Columns, Agilent Technologies

Compare Tool

Select up to 3 products

1 - 32 of 244
Sort
View
Show
  • Capillary Column Ferrules

    Agilent Technologies

    Capillary ferrules are packaged in dial packs which deliver one ferrule at a time, keeping the others clean and ready for use. The dial packaging has been tested to ensure no out gassing of contaminants, including phthalates. *These ferrules are recommended for use with Agilent GC/MS…

  • SampliQ QuEChERS Kits

    Agilent Technologies

    Extraction salts are pre-measured and provided in anhydrous packets, so you can conveniently add them after the acetonitrile and improve results Kits available with ceramic homogenizers to facilitate sample homogenization and to break up salt agglomerates more efficiently than shaking by hand;…

  • ZORBAX Rx-Sil Columns

    Agilent Technologies

    Made from highly pure (>99.995%) porous silica microspheres (pore size is the space between the solid silica microparticles) Stronger than other silica types Less acidic than ZORBAX-SIL, lower metal content Low acidity and low metal content make ZORBAX Rx-SIL ideal for…

  • Column Nuts

    Agilent Technologies

    Agilent MS interface column nuts (or transfer line nuts) are manufactured from a softer metal than the transfer line interface. This is to prevent stripping of the transfer line threads and costly repairs. Add a few MS interface column nuts to your next order and keep spares on hand.

  • ZORBAX Eclipse XDB Columns

    Agilent Technologies

    Agilent ZORBAX Eclipse XDB columns – C18, C8, Phenyl and CN – provide four bonded phase choices for method development optimization. These columns provide good peak shape over a wide pH range (2-9) for additional method development flexibility with one family of columns. Eclipse XDB…

  • UltiMetal Plus Flexible Metal Ferrules

    Agilent Technologies

    Put an end to frustration about GC capillary column connections! With the novel design of our proprietary UltiMetal Plus Flexible Metal ferrule, you can confidently make leak free column unions to capillary flow technology (CFT) devices. These new metal ferrules fix the problems of column breakage…

  • HP-1

    Agilent Technologies

    100% Dimethylpolysiloxane Industry standard general purpose column Non-polar Wide range of applications Superior performance of low molecular weight alcohols High temperature limit Bonded and cross-linked Solvent rinsable Wide range of column dimensions …

  • DB-5ms

    Agilent Technologies

    Phenyl Arylene polymer virtually equivalent to a (5%-Phenyl)-methylpolysiloxane Non-polar Very low bleed, suitable for GC/MS Exhibits inertness to active compounds Temperature limits are -60° to 325°/350°C Improved signal-to-noise ration for increased sensitivity and mass…

  • HP-5

    Agilent Technologies

    GC capillary columns are typically wound on 7 inch cages that fit into standard-sized GCs like the 6890. The 6850 GC has a smaller oven which requires the use of columns wound on a smaller cage diameter. (5%-Phenyl)-methylpolysiloxane Non-polar Excellent general purpose column …

  • HP-Innowax

    Agilent Technologies

    Meets EN1410 and EN14331 Standards Polyethylene glycol (PEG) Close equivalent to USP Phase G16 High polarity Highest upper temperature limits of bonded PEG phases (260°/270°C) Column-to-column repeatability Bonded and cross-linked Solvent rinsable …

  • DB-Wax

    Agilent Technologies

    Polyethylene glycol (PEG) Close equivalent to USP Phase G16 High polarity Lower temperature limit of 20°C is lowest of any bonded PEG phase; improves resolution of low boiling point analytes Column-to-column repeatability Bonded and cross-linked Solvent rinsable …

  • ZORBAX Rx-C18

    Agilent Technologies

    Rx-C18 is recommended for alternate selectivity at low pH relative to Eclipse XDB-C18 and StableBond SB-C18; for higher temperature applications, StableBond is recommended. This column has a higher carbon load than SB-C18 columns (12% vs. 10%) Rx-C18 offers high stability and good peak shape…

  • HP-5

    Agilent Technologies

    (5%-Phenyl)-methylpolysiloxane Non-polar Wide range of applications High temperature limits: -60° to 325°C isothermally, -60° to 350°C programmed. -60° to 300°C isothermally, -60° to 320°C programmed for 0.53 mm columns -60° to 260°/280°C for =2.0 µm films Bonded and cross-linked Solvent…

  • ZORBAX 80 Extend-C18

    Agilent Technologies

    High efficiency and long life at high pH — up to pH 11.5 Unique bidentate bonding and double endcapping provides high pH stability More efficiency and better peak shape than polymer-based columns Improve retention, resolution and peak shape of basic compounds High sensitivity for GC/MS…

  • ZORBAX NH2 Columns

    Agilent Technologies

    Amino-propyl silane phase bonded to ZORBAX SIL Used for normal phase and weak anion-exchange, and reversed-phase  HPLC of polar compounds Vitamins A and D are separated in the normal-phase mode Carbohydrates and sugars are separated in the reversed-phase mode …

  • DB-Wax

    Agilent Technologies

    GC capillary columns are typically wound on 7 inch cages that fit into standard-sized GCs like the 6890. The 6850 GC has a smaller oven which requires the use of columns wound on a smaller cage diameter. Polyethylene glycol (PEG) Close equivalent to USP Phase G16 High polarity …

  • DB-225

    Agilent Technologies

    (50%-Cyanopropylphenyl)-dimethylpolysiloxane Mid/high polarity Excellent for separations of cis- and trans-fatty acid methyl esters (FAMEs) Bonded and cross-linked Solvent rinsable Exact replacement of HP-225 Close equivalent to USP Phase G7 Similar Phases:…

  • HP-1

    Agilent Technologies

    GC capillary columns are typically wound on 7 inch cages that fit into standard-sized GCs like the 6890. The 6850 GC has a smaller oven which requires the use of columns wound on a smaller cage diameter. 100% Dimethylpolysiloxane Non-polar Excellent general purpose column -…

  • DB-624

    Agilent Technologies

    Specifically designed for the analysis of volatile priority pollutants No cryogenics needed for U.S. EPA Method 502.2 Excellent for U.S. EPA Methods: 501.3, 502.2, 503.1, 524.2, 601, 602, 8010, 8015, 8020, 8240 and 8260 Exhibits inertness to active compounds Bonded and cross-linked Solvent…

  • DB-624

    Agilent Technologies

    GC capillary columns are typically wound on 7 inch cages that fit into standard-sized GCs like the 6890. The 6850 GC has a smaller oven which requires the use of columns wound on a smaller cage diameter. Specifically designed for the analysis of volatile priority pollutants No…

  • ZORBAX Gf-250 and Gf-450gel Filtration Columns

    Agilent Technologies

    High efficiency and reproducibility with short analysis time Hydrophilic diol bonded phase for good protein recovery Compatible with organic modifiers and denaturants Wide usable pH range (pH 3-8) ZORBAX GF-250 and GF-450 size exclusion (gel filtration) columns are ideal…

  • HP-Ms

    Agilent Technologies

    GC capillary columns are typically wound on 7 inch cages that fit into standard-sized GCs like the 6890. The 6850 GC has a smaller oven which requires the use of columns wound on a smaller cage diameter. (5%-Phenyl)-methylpolysiloxane Identical selectivity to HP-5 Non-polar …

  • Ultron Chiral Columns

    Agilent Technologies

    Direct racemic separations without derivatization Use Ultron ES-OVM to separate enantiomers of pharmaceuticals, such as hexobarbital, ibuprofen, and profenamine Ultron ES-Pepsin Chiral columns are best suited to separate basic compounds that are difficult to separate by other columns …

  • Amino Acid Standards

    Agilent Technologies

    *Consider shelf-life and buy limited quantities, 2714H95 ships as 1 g vials

  • SampliQ Polymer WAX SPE Cartridges

    Agilent Technologies

    Weak Anion Exchange Exhibits both anion exchange and reversed phase behavior Wide pH range: can be ionized or neutral depending on pH of buffer solution WAX resin retains acidic/anionic; neutral and strong acids Agilent SampliQ WAX is designed to retain and release strong…

  • ZORBAX Rx-C8

    Agilent Technologies

    Rx-C8 is the same product as SB-C8 *RR: Rapid Resolution 3.5 µm

  • Purospher Reversed-Phase Columns

    Agilent Technologies

    An ultrapure spherical silica support, deactivated by an efficient bonding process, makes Purospher an excellent packing for basic compounds. Multistep bonding and deactivating processes provide high surface coverage, blocking residual silanol groups and reducing peak tailing.

  • SampliQ Silica Amino (NH2) SPE Cartridges

    Agilent Technologies

    Normal Phase (Polar) Average particle size of 45 µm and pore diameter of 60Å to reduce pressure drop and increase flow reproducibility Agilent’s trifunctional bonding process provides more stability over monomeric bonding Manufactured to Agilent’s rigorous quality standards…

  • ZORBAX Rapid Resolution 3.5 m Eclipse Columns

    Agilent Technologies

    Reduce analysis time and solvent usage and increase sample throughput High efficiency in short and ultra-short column lengths Available in analytical (4.6 mm) and narrow-bore (2.1 mm) ID Comparable lifetime to 5 µm columns Agilent ZORBAX Rapid Resolution columns, with a 3.5 µm particle size,…

  • Columns Capillary HP-88 100m, 0.25mm id, 0.2um

    Agilent Technologies

    (88%-cyanopropyl) aryl-polysiloxane 250/320°C upper temperature limits High Polarity Designed for separation of cis/trans fatty acid methyl esters Even better separation than DB-23 of cis-trans isomers Similar Phases: CP-Sil 88, SP-2560, SP-2340, SP-2330, BPX-70, BPX-90

  • ZORBAX Carbohydrate Analysis Columns

    Agilent Technologies

    Reproducible - each lot of this application specific aminopropyl column packing material is use-tested for specific monosaccharide and disaccharide separations Efficient - uses ZORBAX porous silica microsphere technology. Silica manufacturing, bonding and packing are all performed in Agilent's…

  • ZORBAX Rapid Resolution High Throughput 1.8 M Columns

    Agilent Technologies

    High pressure (600 bar) columns for ultra high speed or maximum resolution analyses with Rapid Resolution HT columns packed with totally porous, 1.8 µm packings Carefully engineered particles deliver maximum resolution at 25% less pressure than other sub 2-micron materials Reduce…

Compare Tool

Select up to 3 products

Please Log In