Columns

Gas Chromatography Columns, Columns, Restek

Compare Tool

Select up to 3 products

All Products

Restek Columns Gas Chromatography Columns

1 - 32 of 144
Sort
View
Show
  • Rtx-1 Columns (fused silica)

    Restek

    nonpolar phase; Crossbond dimethyl polysiloxane General-purpose columns for solvent impurities, PCB congeners (e.g., Aroclor mixes), simulated distillation, arson accelerants, gases, natural gas odorants, sulfur compounds, essential oils, hydrocarbons, semivolatiles, pesticides, oxygenates. …

  • Rxi-XLB Columns (fused silica)

    Restek

    low-polarity proprietary phase Rxi fused silica capillary GC columns were designed specifically to be the best columns available, for exceptional inertness, ultra-low bleed, and reproducible retention and selectivity. In addition to outstanding performance, this combination of column…

  • Porapak Packing Materials

    Restek

  • Rtx-5MS—Low-Bleed GC-MS Columns (fused silica)

    Restek

    low-polarity phase; Crossbond diphenyl dimethyl polysiloxane General purpose columns for drugs, solvent impurities, pesticides, hydrocarbons, PCB congeners (e.g., Aroclor mixes), essential oils, semivolatiles. Column specifically tested for low-bleed performance. Temperature range:…

  • MXT-1 Columns (Siltek-treated stainless steel)

    Restek

    nonpolar phase; Crossbond dimethyl polysiloxane MXT-1 columns exhibit long lifetime and very low bleed at high operating temperatures. A proprietary synthesis process eliminates residual catalysts that could cause degradation and increase bleed. General-purpose columns for solvent…

  • Hydroguard Water-Resistant Guard/Retention Gap Columns/Transfer Lines (fused…

    Restek

    Extend analytical column lifetime by preventing degradation from harsh “steam-cleaning” water injections. Tested with a comprehensive test mix, to ensure high inertness Maximum temperature: 325°C When transfer lines from purge-and-trap systems, air monitoring equipment,…

  • Rt-XLSulfur Columns

    Restek

    Sulfur analyses are traditionally performed using PTFE tubing to improve column inertness. Unfortunately, PTFE tubing is gas permeable, difficult to pack with high efficiency, prone to shrinkage, and has poor thermal stability. The Rt-XLSulfur packed or micropacked column eliminates these problems.…

  • Rtx-1301 (G43) Columns (fused silica)

    Restek

    low- to midpolarity phase Many analysts feel the Rtx-1301 column has the best cyanosiloxane bonded stationary phase available, with no other column manufacturer providing lower bleed, longer lifetime, or better inertness. Our polymer is fully characterized to ensure long-term reproducibility,…

  • Stabilwax-DB Columns (fused silica)

    Restek

    polar phase; Crossbond base-deactivated Carbowax polyethylene glycol—for amines and basic compounds Stabilwax-DB columns reduce adsorption and improve responses for many basic compounds, without analyte derivatization or column priming. For different selectivity of basic compounds, or…

  • Rxi-35Sil MS Columns (fused silica)

    Restek

    midpolarity Crossbond phase Rxi fused silica capillary GC columns were designed specifically to be the best columns available, for exceptional inertness, ultra-low bleed, and reproducible retention and selectivity. In addition to outstanding performance, this combination of column…

  • Rtx-50 Columns (fused silica)

    Restek

    midpolarity phase; Crossbond phenyl methyl polysiloxane The high thermal stability of Rtx-50 columns makes dual-column analysis possible with common phases such as Rtx-1 or Rtx-5MS. General-purpose columns for pesticides, herbicides, rosin acids, phthalate esters, sterols Equivalent to…

  • Rtx-BAC Plus 2 Columns (fused silica)

    Restek

    These application-specific columns for blood alcohol analysis baseline separate all critical compounds—including ethanol, methanol, acetone, tert-butanol, acetaldehyde, isopropanol, and n-propanol—in less than 2 minutes. Every Rtx-BAC Plus 1 and Rtx-BAC Plus 2 column is qualified with a…

  • Intermediate-Polarity Deactivated MXT Guard/Retention Gap Columns/Transfer Lines…

    Restek

    Useful for a wide range of applications Compatible with most common solvents Maximum temperature: 325°C

  • Rtx-5 (G27) Columns (fused silica)

    Restek

    low-polarity phase; Crossbond diphenyl dimethyl polysiloxane The diphenyl dimethyl polysiloxane stationary phase is the most popular GC stationary phase and is used in a wide variety of applications. All residual catalysts and low molecular weight fragments are removed from the Rtx-5 polymer,…

  • Rtx-200 Columns (fused silica)

    Restek

    midpolarity phase; Crossbond trifluoropropylmethyl polysiloxane Rtx-200 columns have accomplished many difficult separations not possible on any other bonded stationary phase. Many analysts consider these the best, most inert midpolarity columns available. The trifluoropropylmethyl polysiloxane…

  • Rtx-PCB Columns (fused silica)

    Restek

    proprietary Crossbond phase Unique polymer for PCBs analysis by GC-ECD or GC-MS. Good results for other semivolatiles. Low polarity; inert to active compounds. Stable to 340°C

  • MXT-Volatiles Columns (Siltek-treated stainless steel)

    Restek

    proprietary Crossbond diphenyl/dimethyl polysiloxane phase MXT-Volatiles columns were the first columns designed specifically for analyses of the 34 volatile organic pollutants listed in U.S. EPA Methods 601, 602, and 624. With these columns, you can quantify all compounds listed in these…

  • Rtx-CLPesticides Columns (fused silica)

    Restek

    Column bleed, measured by ECD, is extremely low at temperatures up to 330°C, which is critical for baking-out the column to remove high-boiling compounds commonly found in pesticide/PCB extracts. An analysis time of less than 10 minutes improves throughput compared to other stationary phases. …

  • CarboBlack Packing Materials

    Restek

    CarboBlack B supports up to 10% loading of a nonsilicone liquid phase CarboBlack C supports up to 1% loading of a nonsilicone liquid phase Graphitized carbon black offers unique selectivity and very little adsorption for alcohol analyses. Two types of CarboBlack supports are available,…

  • Stabilwax Columns (fused silica)

    Restek

    polar phase; Crossbond polyethylene glycol Restek’s polar-deactivated surface tightly binds the Carbowax polymer and increases thermal stability, relative to competitive columns. Because of the increased stability produced by the bonding process, Stabilwax columns exhibit long column…

  • Rtx-502.2 Columns (fused silica)

    Restek

    proprietary Crossbond diphenyl/dimethyl polysiloxane phase An Rtx-502.2 column will enable you to quantify all compounds listed in U.S. EPA methods 502.2 or 524.2, whether you use a mass spectrometer or a PID in tandem with an ELCD. The diphenyl/dimethyl polysiloxane based Rtx-502.2 stationary…

  • Rtx-CLPesticides2 Columns (fused silica)

    Restek

    proprietary Crossbond phase Improved resolution and faster analyses, compared to 1701 or phenyl phases, make these the pesticide columns of choice. Rtx-CLPesticides columns are specially designed to overcome the coelutions and analyte breakdown typically encountered in chlorinated pesticide…

  • Rxi-17Sil MS Columns (fused silica)

    Restek

    midpolarity Crossbond phase Rxi fused silica capillary GC columns were designed specifically to be the best columns available, for exceptional inertness, ultra-low bleed, and reproducible retention and selectivity. In addition to outstanding performance, this combination of column…

  • Siltek-Deactivated Guard/Retention Gap Columns/Transfer Lines (fused silica)

    Restek

    Tested with a comprehensive test mix, to ensure high inertness Revolutionary deactivation process for superior inertness Analyze active samples accurately; ideal for chlorinated pesticide analysis (reduces endrin breakdown to less than 1%) Maximum temperature: 380°C

  • Rxi-5ms Columns (fused silica)

    Restek

    low-polarity phase; Crossbond diphenyl dimethyl polysiloxane Rxi fused silica capillary GC columns were designed specifically to be the best columns available, for exceptional inertness, ultra-low bleed, and reproducible retention and selectivity. In addition to outstanding performance, this…

  • OPN on Res-Sil C Column (packed)

    Restek

    This column separates the light hydrocarbons, and baseline resolves cis-2-butene from 1,3-butadiene. Special Columns for Unsaturated Light Hydrocarbons Faster separations of C1 to C4 hydrocarbons. Res-Sil packing replaces Porasil materials.

  • Rxi-5Sil MS Columns (fused silica)

    Restek

    low-polarity phase; Crossbond 1,4-bis(dimethylsiloxy)phenylene dimethyl polysiloxane Rxi fused silica capillary GC columns were designed specifically to be the best columns available, for exceptional inertness, ultra-low bleed, and reproducible retention and selectivity. In addition to…

  • MXT-50 Columns (Siltek-treated stainless steel)

    Restek

    midpolarity phase; Crossbond phenyl methyl polysiloxane General-purpose columns for pesticides, herbicides, rosin acids, phthalate esters, and sterols. Temperature range: 0°C to 300°C. Equivalent to USP G3 phase. 4.5" standard coil diameter.

  • MXT-5 Columns (Siltek-treated stainless steel)

    Restek

    low-polarity phase; Crossbond diphenyl dimethyl polysiloxane The diphenyl dimethyl polysiloxane stationary phase is the most popular GC stationary phase and is used in a wide variety of applications. All residual catalysts and low molecular weight fragments are removed from the MXT-5 polymer,…

  • Rt-Q-BOND Columns (fused silica PLOT)

    Restek

    100% divinylbenzene Porous polymers are unique, highly retentive stationary phases with a wide application range that are able to elute both polar and nonpolar compounds. They are very hydrophobic, so water has no impact on retention times and even elutes as a good chromatographic peak. The…

  • Rxi-1301Sil MS Columns (fused silica)

    Restek

    midpolarity Crossbond phase Cyano-based 1301 columns are general use GC columns that are well suited for the analysis of solvents across a range of volatilities. The cyano stationary phase provides more retention of polar compounds than a 5-type column; however, cyano-based stationary phases…

  • Rtx-65 Columns (fused silica)

    Restek

    mid- to high-polarity phase; Crossbond diphenyl dimethyl polysiloxane The Rtx-65 phase contains the highest phenyl content of any bonded stationary phase available to improve separation of aromatic compounds through increased phase-analyte interaction. A unique polarity makes these columns…

Compare Tool

Select up to 3 products

Please Log In

Don't have an Account? Create one now.