  • Rtx-1301 (G43) Columns (fused silica)

    Restek

    low- to midpolarity phase Many analysts feel the Rtx-1301 column has the best cyanosiloxane bonded stationary phase available, with no other column manufacturer providing lower bleed, longer lifetime, or better inertness. Our polymer is fully characterized to ensure long-term reproducibility,…

  • Stabilwax Columns (fused silica)

    Restek

    polar phase; Crossbond polyethylene glycol Restek’s polar-deactivated surface tightly binds the Carbowax polymer and increases thermal stability, relative to competitive columns. Because of the increased stability produced by the bonding process, Stabilwax columns exhibit long column…

  • Rtx-5 (G27) Columns (fused silica)

    Restek

    low-polarity phase; Crossbond diphenyl dimethyl polysiloxane The diphenyl dimethyl polysiloxane stationary phase is the most popular GC stationary phase and is used in a wide variety of applications. All residual catalysts and low molecular weight fragments are removed from the Rtx-5 polymer,…

  • Rtx-200 Columns (fused silica)

    Restek

    midpolarity phase; Crossbond trifluoropropylmethyl polysiloxane Rtx-200 columns have accomplished many difficult separations not possible on any other bonded stationary phase. Many analysts consider these the best, most inert midpolarity columns available. The trifluoropropylmethyl polysiloxane…

  • MXT-1 Columns (Siltek-treated stainless steel)

    Restek

    nonpolar phase; Crossbond dimethyl polysiloxane MXT-1 columns exhibit long lifetime and very low bleed at high operating temperatures. A proprietary synthesis process eliminates residual catalysts that could cause degradation and increase bleed. General-purpose columns for solvent…

  • Rtx-OPPesticides2 Columns (fused silica)

    Restek

    proprietary Crossbond phase Using sophisticated computer modeling software, we created two stationary phases for separating the 53 organophosphorus pesticides (OPP) listed in EPA Method 8141. Separation is improved and analysis time is significantly reduced, compared to other columns. The…

  • Rxi-624Sil MS Columns (fused silica)

    Restek

    midpolarity Crossbond phase Rxi fused silica capillary GC columns were designed specifically to be the best columns available, for exceptional inertness, ultra-low bleed, and reproducible retention and selectivity. In addition to outstanding performance, this combination of column…

  • ShinCarbon ST Columns

    Restek

    Analyze oxygen, nitrogen, methane, carbon monoxide, and carbon dioxide with one column at room temperature. ShinCarbon ST material, a high surface area carbon molecular sieve (~1,500 m 2 /g), is the ideal medium for separating gases and highly volatile compounds by gas solid chromatography (GSC).…

  • Stabilwax-DB Columns (fused silica)

    Restek

    polar phase; Crossbond base-deactivated Carbowax polyethylene glycol—for amines and basic compounds Stabilwax-DB columns reduce adsorption and improve responses for many basic compounds, without analyte derivatization or column priming. For different selectivity of basic compounds, or…

  • Rtx-1 Columns (fused silica)

    Restek

    nonpolar phase; Crossbond dimethyl polysiloxane General-purpose columns for solvent impurities, PCB congeners (e.g., Aroclor mixes), simulated distillation, arson accelerants, gases, natural gas odorants, sulfur compounds, essential oils, hydrocarbons, semivolatiles, pesticides, oxygenates. …

  • Rxi-5ms Columns (fused silica)

    Restek

    low-polarity phase; Crossbond diphenyl dimethyl polysiloxane Rxi fused silica capillary GC columns were designed specifically to be the best columns available, for exceptional inertness, ultra-low bleed, and reproducible retention and selectivity. In addition to outstanding performance, this…

  • Rxi-1ms Columns (fused silica)

    Restek

    nonpolar phase; Crossbond dimethyl polysiloxane Rxi fused silica capillary GC columns were designed specifically to be the best columns available, for exceptional inertness, ultra-low bleed, and reproducible retention and selectivity. In addition to outstanding performance, this combination of…

  • Rtx-1701 Columns (fused silica)

    Restek

    midpolarity Crossbond phase Rtx-1701 is one of the more popular stationary phases used in capillary GC. The mix of cyano and phenyl functional groups increases the polarity and offers a different elution order relative to less polar Rtx-1 or Rtx-5 columns. An Rtx-1701 column is ideal for…

  • Rtx-BAC1 Columns (fused silica)

    Restek

    proprietary Crossbond phase These columns separate to baseline all blood alcohol compounds in blood, breath, or urine, in less than 3 minutes, under isothermal conditions. Isothermal analysis increases productivity by eliminating the need for oven cycling. Confirmation is easily achieved with…

  • Rtx-BAC2 Columns (fused silica)

    Restek

    proprietary Crossbond phase These columns separate to baseline all blood alcohol compounds in blood, breath, or urine, in less than 3 minutes, under isothermal conditions. Isothermal analysis increases productivity by eliminating the need for oven cycling. Confirmation is easily achieved with…

  • Siltek-Deactivated Guard/Retention Gap Columns/Transfer Lines (fused silica)

    Restek

    Tested with a comprehensive test mix, to ensure high inertness Revolutionary deactivation process for superior inertness Analyze active samples accurately; ideal for chlorinated pesticide analysis (reduces endrin breakdown to less than 1%) Maximum temperature: 380°C

  • MXT-5 Columns (Siltek-treated stainless steel)

    Restek

    low-polarity phase; Crossbond diphenyl dimethyl polysiloxane The diphenyl dimethyl polysiloxane stationary phase is the most popular GC stationary phase and is used in a wide variety of applications. All residual catalysts and low molecular weight fragments are removed from the MXT-5 polymer,…

  • CarboBlack Packing Materials

    Restek

    CarboBlack B supports up to 10% loading of a nonsilicone liquid phase CarboBlack C supports up to 1% loading of a nonsilicone liquid phase Graphitized carbon black offers unique selectivity and very little adsorption for alcohol analyses. Two types of CarboBlack supports are available,…

  • Rtx-65 Columns (fused silica)

    Restek

    mid- to high-polarity phase; Crossbond diphenyl dimethyl polysiloxane The Rtx-65 phase contains the highest phenyl content of any bonded stationary phase available to improve separation of aromatic compounds through increased phase-analyte interaction. A unique polarity makes these columns…

  • Stabilwax-DA Columns (fused silica)

    Restek

    polar phase; Crossbond acid-deactivated Carbowax polyethylene glycol—for acidic compounds Stabilwax-DA bonded polyethylene glycol has an acidic functionality incorporated into the polymer structure. This permits analysis of acidic compounds without derivatization, significantly reduces…

  • Rxi-17 Columns (fused silica)

    Restek

    midpolarity phase; Crossbond diphenyl dimethyl polysiloxane Rxi fused silica capillary GC columns were designed specifically to be the best columns available, for exceptional inertness, ultra-low bleed, and reproducible retention and selectivity. In addition to outstanding performance, this…

  • Res-Sil Packing Materials

    Restek

    Unique separation of saturated and unsaturated hydrocarbons. Innovative bonding chemistry for batch-to-batch reproducibility, excellent thermal stability, and long life. Wide range of bonded phases available. Equivalent to Durapak and Porasil packings. Bonded silica packings with…

  • Rtx-5 Amine Columns (fused silica)

    Restek

    low-polarity phase; Crossbond 5% diphenyl/95% dimethyl polysiloxane Active basic compounds that otherwise require derivatization, or an alternative analytical technique, can be analyzed on an Rtx-5 Amine column. The tubing surface is chemically altered to reduce tailing of basic compounds,…

  • Rtx-225 Columns (fused silica)

    Restek

    polar phase; Crossbond cyanopropylmethyl phenylmethyl polysiloxane The cyanopropyl-containing Rtx-225 phase is slightly less polar than bonded polyethylene glycol (PEG) phases, but it can be used for many of the same applications. Improvements to the Rtx-225 polymer have increased thermal…

  • Rxi Guard/Retention Gap Columns (fused silica)

    Restek

    Extend column lifetime. Excellent inertness—obtain lower detection limits for active compounds. Sharper chromatographic peaks by utilizing retention gap technology. Maximum temperature: 360°C

  • Rtx-CLPesticides Columns (fused silica)

    Restek

    Column bleed, measured by ECD, is extremely low at temperatures up to 330°C, which is critical for baking-out the column to remove high-boiling compounds commonly found in pesticide/PCB extracts. An analysis time of less than 10 minutes improves throughput compared to other stationary phases. …

  • FAMEWAX Columns (USP G16) (fused silica)

    Restek

    polar phase; Crossbond polyethylene glycol The elution order of polyunsaturated FAMEs on FAMEWAX columns is comparable to that on other Carbowax columns, but baseline resolution is achieved in significantly less time. Application-specific columns for FAMEs, specially tested with a FAME…

  • Rtx-VRX Columns (fused silica)

    Restek

    proprietary Crossbond phase The Rtx-VRX stationary phase and optimized column dimensions provide low bleed, excellent resolution, and fast analysis times for volatile compounds. Application-specific columns for volatile organic pollutants. Excellent for U.S. EPA Method 8021 compounds. …

  • Porous Polymer Columns

    Restek

    Restek offers a full range of porous polymers, including HayeSep and Porapak polymer packings for analyses of volatile compounds and light solvents.

  • Rxi-17Sil MS Columns (fused silica)

    Restek

    midpolarity Crossbond phase Rxi fused silica capillary GC columns were designed specifically to be the best columns available, for exceptional inertness, ultra-low bleed, and reproducible retention and selectivity. In addition to outstanding performance, this combination of column…

  • Intermediate-Polarity Deactivated Guard/Retention Gap Columns/Transfer Lines …

    Restek

    Tested with a comprehensive test mix to ensure high inertness. Useful for a wide range of applications. Use with most common solvents. Maximum temperature: 325°C. *30- and 60-meter lengths are banded in 5-meter sections. †Recommendation: Cut 60 m guard columns into shorter…

  • Rtx-200 Secondary Columns for GCxGC (fused silica)

    Restek

    midpolarity phase; Crossbond trifluoropropylmethyl polysiloxane Rtx-200 columns have accomplished many difficult separations not possible on any other bonded stationary phase. Many analysts consider these the best, most inert midpolarity columns available. The trifluoropropyl stationary phase…