Show
  • DB-5ms

    Agilent Technologies

    Phenyl Arylene polymer virtually equivalent to a (5%-Phenyl)-methylpolysiloxane Non-polar Very low bleed, suitable for GC/MS Exhibits inertness to active compounds Temperature limits are -60° to 325°/350°C Improved signal-to-noise ration for increased sensitivity and mass…

  • DB-624

    Agilent Technologies

    Specifically designed for the analysis of volatile priority pollutants No cryogenics needed for U.S. EPA Method 502.2 Excellent for U.S. EPA Methods: 501.3, 502.2, 503.1, 524.2, 601, 602, 8010, 8015, 8020, 8240 and 8260 Exhibits inertness to active compounds Bonded and cross-linked Solvent…

  • Capillary Column Ferrules

    Agilent Technologies

    Capillary ferrules are packaged in dial packs which deliver one ferrule at a time, keeping the others clean and ready for use. The dial packaging has been tested to ensure no out gassing of contaminants, including phthalates. *These ferrules are recommended for use with Agilent GC/MS…

  • HP-5ms

    Agilent Technologies

    Meets EN14331 Standards (5%-Phenyl)-methylpolysiloxane Non-polar Very low bleed, suitable for GC/MS Exhibits inertness to active compounds Temperature limits are -60° to 325°/350°C Improved signal-to-noise ration for increased sensitivity and mass spectral integrity Bonded and cross-linked…

  • HP-1

    Agilent Technologies

    100% Dimethylpolysiloxane Industry standard general purpose column Non-polar Wide range of applications Superior performance of low molecular weight alcohols High temperature limit Bonded and cross-linked Solvent rinsable Wide range of column dimensions …

  • DB-624

    Agilent Technologies

    GC capillary columns are typically wound on 7 inch cages that fit into standard-sized GCs like the 6890. The 6850 GC has a smaller oven which requires the use of columns wound on a smaller cage diameter. Specifically designed for the analysis of volatile priority pollutants No…

  • HP-5

    Agilent Technologies

    (5%-Phenyl)-methylpolysiloxane Non-polar Wide range of applications High temperature limits: -60° to 325°C isothermally, -60° to 350°C programmed. -60° to 300°C isothermally, -60° to 320°C programmed for 0.53 mm columns -60° to 260°/280°C for =2.0 µm films Bonded and cross-linked Solvent…

  • DB-FFAP

    Agilent Technologies

    Nitroterephthalic acid modified polyethylene glycol High polarity Designed for the analysis of volatile fatty acids and phenols Bonded and cross-linked Solvent rinsable Close equivalent to USP Phase G35 Temperature limits: 40° to 250°C NOTE: Agilent does…

  • DB-608

    Agilent Technologies

    Specifically designed for the analysis of chlorinated pesticides and PCBs U.S. EPA Methods: 608, 508, 8080 Excellent inertness and recoveries without pesticide breakdown Bonded and cross-linked Solvent rinsable Exact replacement of HP-608 Similar Phases: SPB-608,…

  • DB-Wax

    Agilent Technologies

    Polyethylene glycol (PEG) Close equivalent to USP Phase G16 High polarity Lower temperature limit of 20°C is lowest of any bonded PEG phase; improves resolution of low boiling point analytes Column-to-column repeatability Bonded and cross-linked Solvent rinsable …

  • DB-VRX 60m, .25mm, 1.4um, 5"Cage

    Agilent Technologies

    GC capillary columns are typically wound on 7 inch cages that fit into standard-sized GCs like the 6890. The 6850 GC has a smaller oven which requires the use of columns wound on a smaller cage diameter. Unique selectivity engineered for optimum resolution of volatiles analysis: U.S. EPA…

  • DB-Petro

    Agilent Technologies

    100% Dimethylpolysiloxane Configured for the analysis of petroleum process products PONA, PIANO High resolution Bonded and cross-linked Solvent rinsable Similar Phases: Petrocol DH, HP-PONA, SPB-1, 007-1, Rtx-1, MXT-1 100 psi regulator required to reach optimum…

  • DB-5.625

    Agilent Technologies

    Equivalent to a (5%-Phenyl)-methylpolysiloxan Non-polar Specially processed to exhibit excellent inertness for EPA Semivolatiles Methods 625, 1625, 8270 and CLP protocols* Surpasses EPA performance criteria for semivolatiles Inert for base, neutral and acidic compounds High…

  • Reducing Ferrules

    Agilent Technologies

  • Column GC Cap High Efficiency HP-1ms 20m, 0.18mm, 0.18um

    Agilent Technologies

    100% Dimethylpolysiloxane Non-polar Low bleed characteristics Improved signal-to-noise ratio for better sensitivity and mass spectral integrity Bonded and cross-linked and solvent rinsable

  • Column GC Cap High Efficiency DB-35ms 20m, 0.18mm, 0.18um

    Agilent Technologies

    Virtually equivalent to a (35%-Phenyl)-methylpolysiloxane Midpolarity Very low bleed characteristics Extended temperature limit of 340/360°C Excellent inertness for active compounds Ideal for conformational analyses Bonded, cross-linked and solvent rinsable

  • GS-Carbonplot

    Agilent Technologies

    Agilent J&W GS-CarbonPLOT uses a high stability, carbon-layer stationary phase to deliver unique selectivity for inorganic and organic gases. The column features an extended temperature limit to 360 °C. The retention stability of GS-CarbonPLOT is not affected by water, and the column is…

  • HP-Voc

    Agilent Technologies

    • New Bullet • New Bullet • New Bullet • New Bullet • New Bullet • New Text

  • Hp Blood Alcohol Analysis, 5" Cage

    Agilent Technologies

    GC capillary columns are typically wound on 7 inch cages that fit into standard-sized GCs like the 6890. The 6850 GC has a smaller oven which requires the use of columns wound on a smaller cage diameter. Reliable blood alcohol analysis Excellent confirmation column with DB-ALC2 for…

  • Undeactivated Fused Silica Tubing

    Agilent Technologies

    Undeactivated tubing or bare fused silica is commonly used for capillary electrophoresis. It can also be used for transfer lines and other applications where inertness is not critical.

  • DB-1

    Agilent Technologies

    GC capillary columns are typically wound on 7 inch cages that fit into standard-sized GCs like the 6890. The 6850 GC has a smaller oven which requires the use of columns wound on a smaller cage diameter. 100% Dimethylpolysiloxane Non-polar Excellent general purpose column …

  • DB-200

    Agilent Technologies

    (35% Trifluoropropyl)-methylpolysiloxane 300/320°C temperature limit Midpolarity (more polar than DB-1701 or DB-17) Ideal for difficult to separate positional isomers Unique interactions with compounds containing nitro, halogen and carbonyl groups Low ECD bleed …

  • DB-17ms

    Agilent Technologies

    Virtually equivalent to (50%-Phenyl)-methylpolysiloxane 320°/340°C upper temperature limit Very low bleed midpolarity, suitable for GC/MS Exhibits inertness to active compounds Enhanced mass spectral integrity Bonded and cross-linked Solvent rinsable Best…

  • CAM

    Agilent Technologies

    Base deactivated polyethylene glycol Specifically designed for amine analysis Excellent peak shape for primary amines Replaces HP-Basicwax Similar Phases: Stabilwax-DB, Carbowax Amine Because the CAM is not bonded or cross-linked, we do not recommend solvent rinsing.

  • HP-PAS-5 25m, 0.32mm, 0.52um

    Agilent Technologies

    Non-polar Specifically designed and processed for the analysis of organochlorine pesticides ECD tested to assure minimal pesticide breakdown and low ECD bleed Bonded and cross-linked Solvent rinsable Similar Phases: DB-5, Ultra-2, SPB-5, CP-Sil 8CB, RSL-200, Rtx-5, BP-5,…

  • HP-Pona

    Agilent Technologies

    100% Dimethylpolysiloxane Configured for the analysis of petroleum process products Tested to ensure the resolution of m-xylene from p-xylene and of cyclopentane from 2,3-dimethylbutane PONA, PIANO High resolution Bonded and cross-linked Solvent rinsable Similar…

  • DB-225ms

    Agilent Technologies

    Virtually equivalent to (50%-Cyanopropylphenyl)-methylpolysiloxane Mid/high polarity Excellent for separations of cis- and trans-fatty acid methyl esters (FAMEs) Low bleed Bonded and cross-linked Solvent rinsable Close equivalent to USP Phase G7 Similar Phases:…

  • HP-Innowax

    Agilent Technologies

    Meets EN1410 and EN14331 Standards Polyethylene glycol (PEG) Close equivalent to USP Phase G16 High polarity Highest upper temperature limits of bonded PEG phases (260°/270°C) Column-to-column repeatability Bonded and cross-linked Solvent rinsable …

  • DB-Waxetr

    Agilent Technologies

    Polyethylene glycol (PEG) Extended Temperature Range (etr) High polarity Excellent column-to-column repeatability Bonded and cross-linked Solvent rinsable Close equivalent to USP Phase G16 Similar Phases: HP-20M, SUPELCOWAX 10, CP-WAX 52 CB, SUPEROX II, CB-WAX,…

  • Column GC Cap High Efficiency DB-1701 20m, 0.18mm, 0.18um

    Agilent Technologies

    (14%-Cyanopropyl-phenyl)-methylpolysiloxane Low/midpolarity Bonded and cross-linked Solvent rinsable Available with DuraGuard

  • Column GC Cap High Efficiency DB-Innowax 20m, 0.18mm, 0.18um

    Agilent Technologies

    Polyethylene glycol (PEG) High polarity Highest upper temperature limits of bonded PEG phases Column-to-column repeatability Bonded and cross-linked Solvent rinsable

  • DB-MTBE

    Agilent Technologies

    Low polarity stationary phase Resolves MTBE from 2-methylpentane and 3-methylpentane for better quantitation Engineered for purge and trap injection without the need for cryofocusing Bonded and cross-linked Solvent rinsable

Compare Tool