Qualitative GC and GC/MS Instrument Evaluation Standards
Thomas No.
Mfr. No.
Item
Description
Price
2715B59
85004789
Capillary Inlet Evaluation Sample (Split Mode)
Solution of 1.0% (w/w) C9, C16 in C14. Three 0.5 ml ampoules.
$46.04
2713Y06
1871060170
FID and TCD Sample
This sample is used for the HP 5880, 5890 and 6890 with a FID or TCD. Solution of 0.033% C14, C15, and C16 normal alkanes in hexane. Three 0.5 ml ampoules.
$48.60
2713Y21
1878960060
Nitrogen-Phosphorus Detector Sample
This sample is used for the HP 5880, 5890 and 6890 with a NPD. Solution of 0.65 ppm azobenzene, 1,000 ppm octadecane, and 1.00 ppm malathion in isooctane (w/v). Three 0.5 ml ampoules.
$46.04
2713Y07
1871160060
Thermal Conductivity Detector Sample
Solution of 0.33% C14, C15, and C16 normal alkanes in hexane (w/w). Three 0.5 ml ampoules.
$51.18
2713Y08
1871360040
Electron Capture Detector Sample
This sample is used for the HP 5880, 5890 and 6890 with an ECD. Solution of 33 pg/mL (0.033 ppm) (w/v) each of lindane and aldrin in isooctane. Three 0.5 ml ampoules.
$51.18
2714R75
51830379
ECD Test Sample
Lindane, 0.033 ppm in iso-octane, 3 ampoules
$83.93
1233L81
51885953
Flame Photometric Detector (FPD) Check Out Sample
3 x 1 ml ampoules, Methyl Parathion in Isooctane 2.5 mg/L
$46.78
2714D61
1930560580
Flame Photometric Detector (FPD) Sample
This sample is used for the HP 5880, 5890 and 6890 with an FPD. Solution of 20 ng/µl (20 ppm) dodecanethiol and tributylphosphate in isooctane. Three 0.5 ml ampoules.
Test mixture containing approximately 1% each of ethanol, isopropanol, n-propanol, sec-butanol, isobutyl alcohol, tert-amyl alcohol, and n-butanol; 2% each of methanol and tert-butyl alcohol; and 3% MTBE in gasoline. Three sealed 0.5 ml ampoules.
$122.00
2714L62
50808756
Natural Gas Sample
Approximate concentrations % volume/volume: 69% methane, 6% nitrogen, 1% carbon dioxide, 0.5% oxygen, 9% ethane, 1% npentane, 6% propane, 3% isobutane, 3% n-butane, 1% iso-pentane and 0.5% hexanes. One pressurized aerosol-type container (370 ml at 25 psig
$138.00
2714L63
50808759
Transformer Gas Sample
Approximate composition: 0.1% each of carbon dioxide, propylene, hydrogen, carbon monoxide, propane, ethane, methane, ethylene, acetylene, butene-1, and 99% nitrogen. One pressurized aerosol-type container (16 oz/473 mL at 120 psig).
Multiple component mixture of hydrocarbons from petroleum fractions. Used for performance verification of the Agilent simulated distillation analyzer, Option 840. The analyzer performs analysis of petroleum fractions according to ASTM Method D 2887. Three
$108.00