Thomas Nos. 1215Y44/1215Y45
Air Velocity/Air Flow meter with telescoping probe designed to fit into HVAC ducts and other small openings
- Telescoping probe extends up to 7.05ft (215cm) maximum length with cable
- Adjustable data sampling rate
- Stores 99 readings manually and 20M readings via 2G SD card
- Type K/J Thermocouple input for high temperature measurements
- Large (9999 count) LCD displays Air Velocity or Air Flow and Temperature simultaneously
- Record/Recall MIN, MAX, Data Hold and Auto power off
- Built-in PC interface
- Complete with 6 x AA batteries, SD card, telescoping probe with cable, and hard carrying case
Thomas Nos. 1215Y46/1215Y47
Relative Humidity, Temperature, Dew Point, and Wet Bulb measurement
- Adjustable data sampling rate
- Stores 99 readings manually and 20M readings via 2G SD card
- Type K/J Thermocouple input for high temperature measurements
- Large backlit dual LCD display
- Record/Recall MIN, MAX, Data Hold and Auto power off
- Built-in PC interface
- Complete with 6 x AA batteries, SD card, carrying case and Humidity/Temperature probe
Thomas No. 1215Y49
23.7" (600mm) Heavy Duty Stainless Steel Probe with Replaceable Probe Head with inner filter
- Measures Moisture Content, Air Temperature, Dew Point and Temperature
- Moisture content measurement from 10 to 95%
- Datalogger date/time stamps and stores readings on an SD card in Excel® format for easy transfer to a PC
- Adjustable data sampling rate: 1 to 3600 seconds
- Stores 99 readings manually and 20M readings via 2G SD card
- Type K/J Thermocouple input for high temperature measurements
- Large backlit dual LCD display simultaneously displays Moisture Content and Temperature
- Record/Recall MIN, MAX, Data Hold, Auto Power Off
- Built-in PC interface
- Complete with Moisture Content Probe with 4.9ft (1.5m) cable, sensor cap, SD card, 9V battery and soft carrying case
Thomas Nos. 1215Y50/1215Y51
High accuracy ±1.4dB meets ANSI and IEC 61672-1 Type 2 standards
- 30 to 130dB measurement range
- Auto or Manual ranging
- AC analog output for connection to an analyzer or recorder
- Large backlit LCD display
- Stores 99 readings manually and 20M readings via 2G SD card
- Datalogger date/time stamps and stores readings on an SD card in Excel® format for easy transfer to a PC
- User programmable sampling rate: 1 to 3600 seconds
- Min/Max, Data Hold, Auto Power Off
- Built-in PC interface
- Complete with 6 AA batteries, SD Card, wind screen, and hard carrying case
Thomas Nos. 1215Y52/1215Y53
Accepts interchangeable transducers with ranges of 30, 150, 300psi (transducers sold separately)
- Meter automatically senses plug-in transducer's range and calibration
- Displays 10 types of pressure units
- Offset adjustment used for zero function to make relative measurements
- Adjustable data sampling rate: 1 second to 8hrs:59min:59sec
- Stores 99 readings manually and 20M readings via 2G SD card
- Large backlit dual LCD display
- Record/Recall MIN, MAX, Data Hold, Auto Power Off
- Built-in PC interface
- Complete with 6 x AA batteries, SD card, and hard carrying case (transducers sold separately)
Thomas No. 1215Y54
Remote vibration sensor with magnetic adapter on 47.2"(1.2m) cable
- Wide frequency range of 10Hz to 1kHz
- Basic accuracy of ±(5% + 2 digits); Meets ISO2954
- RMS, Peak Value or Max Hold measurement modes
- Adjustable data sampling rate
- Offset adjustment used for zero function to make relative measurements
- Large backlit LCD
- Stores 99 readings manually and 20M readings via 2G SD card
- Record/Recall MIN, MAX, Data Hold and Auto power off
- Built-in PC interface
- Complete with remote sensor, magnetic mount, 6 x AA batteries, SD card, and hard carrying case
Thomas No.. 1215Y44/1215Y45
Specifications | Range | Resolution | Basic Accuracy |
Fc Range | 200, 2000, 10kFc | 0.1Fc | ±4%rdg |
Lux Range | 2000, 20k, 100kLux | 1Lux | ±4%rdg |
Type K Temperature | -148 to 2372°F (-100 to 1300°C) | 0.1° | ±(0.4% + 1.8°F/1°C) |
Type J Temperature | -148 to 2192°F (-100 to 1200°C) | 0.1° | ±(0.4% + 1.8°F/1°C) |
Memory | 20M data records using 2G SD card |
Dimensions | 7.2 x 2.9 x 1.9" (182 x 73 x 47.5mm) |
Weight | 16.2oz (475g) |
Thomas No.. 1215Y46/1215Y47
Specifications | Range | Resolution | Basic Accuracy |
Humidity | 5% to 95% | 0.1% | ±3% |
Temperature | 32 to 122°F (0 to 50°C) | 0.1° | ±1.8°F (±1°C) |
Dew Point | -13.5 to 120.1°F (-25.3 to 48.9°C) | 0.1° | calculated |
Wet Bulb | -6.9 to 122°F (-21.6 to 50°C) | 0.1° | calculated |
Type K Temperature | -148 to 2372°F (-100 to 1300°C) | 0.1° | ±(0.4% + 1.8°F/1°C) |
Type J Temperature | -148 to 2192°F (-100 to 1200°C) | 0.1° | ±(0.4% + 1.8°F/1°C) |
Memory | 20,000K data records using 2G SD card |
Dimensions | 7.2 x 2.9 x 1.9" (182 x 73 x 47.5mm) |
Weight | 23.1oz (655g) |
Thomas No.. 1215Y49
Specifications | Range | Resolution | Basic Accuracy |
Moisture Content | 10 to 95% | 0.1% | 3% of reading |
Air Temperature | 32 to 122°F (0 to 50°C) | 0.1° | 1.8°F/1°C |
Dew Point | -13 to 120°F (-25 to 50°C) | 0.1° | calculated |
Type K Temperature | -148 to 2372°F (-100 to 1300°C) | 0.1° | (0.2% + 1.8°F/1°C) |
Type J Temperature | -148 to 2192°F (-100 to 1200°C) | 0.1° | (0.2% + 1.8°F/1°C) |
Memory | 20M data records using 2G SD card |
Dimensions | Meter: 7.2 x 2.9 x 1.9" (182 x 73 x 47.5mm); Probe: 23.8" (605mm) x 0.9" (22mm) dia |
Weight | Meter: 8.6oz (245g); Probe: 19.8oz (560g) |
Thomas No.. 1215Y50/1215Y51
Specifications |
Range | 30 to 130dB (3 ranges) |
Basic accuracy | ±1.4dB |
Frequency Range | 31.5 to 8000Hz |
Weighting | A and C |
Response Time | Fast (125ms) / Slow (1s) |
Datalogging | 20M data records using a 2G SD card |
Analog Output | AC |
PC Interface | USB |
Dimensions | 9.8 x 2.9 x 1.9" (250 x 73 x 48mm) |
Weight | 18.3oz (520g) |
Thomas No.. 1215Y52/1215Y53
Sensor Type | 30psi Ranges | 150psi Ranges | 300psi Ranges |
bar | 0.002 to 2 | 0.01 to 10 | 0.02 to 20 |
psi | 0.02 to 29 | 0.2 to 145 | 0.2 to 290 |
kg/cm2 | 0.002 to 2.040 | 0.01 to 10.19 | 0.02 to 20.40 |
mmHg | 2 to 1500 | 10 to 7500 | 20 to 15000 |
inHg | 0.05 to 59.05 | 0.2 to 295.2 | 0.5 to 590.5 |
mH2O | 0.02 to 20.40 | 0.1 to 101.9 | 0.2 to 204.0 |
inH2O | 1 to 802 | 5 to 4010 | 10 to 8020 |
atm | 0.002 to 1.974 | 0.01 to 9.87 | 0.02 to 19.74 |
hPA | 2 to 2000 | 10 to 10000 | 20 to 20000 |
kPA | 0.2 to 200.0 | 1 to 1000 | 2 to 2000 |
Memory | 20M data records using 2G SD card |
Dimensions | 7.2 x 2.9 x 1.9" (182 x 73 x 48mm) |
Weight | 17.3oz (490g) |
Thomas No.1215Y54
Specifications |
Acceleration Velocity | 656ft/s2, 200m/s2, 20.39g 7.87in/s, 200mm/s, 19.99cm/s |
Displacement | 0.078in, 2mm (peak-to-peak) |
Resolution | 1ft/s2, 0.1m/s2, 0.01g; 0.01in/s, 0.1mm/s, 0.01cm/s; 0.001in, 0.001mm |
Basic accuracy | ±(5%+2 digits) |
Memory | 20,000K data records using 2G SD card |
Dimensions | 7.2 x 2.9 x 1.9" (182 x 73 x 47.5mm) |
Weight | 21.1oz (599g) |