EMD Logo
Material Safety Data Sheet
Section 1. Product and Company Identification
Product Name EM QUANT ® Calcium Test Product Code 10083
Manufacturer
EMD Chemicals Inc.
P.O. Box 70
480 Democrat Road
Gibbstown, NJ 08027
Prior to January 1, 2003 EMD Chemicals Inc. was EM Industries, Inc. or EM Science, Division of EM Industries, Inc.
Effective Date
9/16/2004
For More Information Call In Case of Emergency Call
856-423-6300 Technical Service
Monday-Friday: 8:00 AM - 5:00 PM
800-424-9300 CHEMTREC (USA)
613-996-6666 CANUTEC (Canada)
24 Hours/Day: 7 Days/Week
Synonym
EM QUANT ® Calcium Test Reagent No. 1 of two reagents.
EM QUANT ® Calcium Test Reagent No. 2 of two reagents
Material Uses
EM QUANT ® Calcium Test Analytical reagent.
EM QUANT ® Calcium Test Analytical reagent.
Chemical Family
EM QUANT ® Calcium Test Peroxide.
EM QUANT ® Calcium Test Solution.


Section 2. Composition and Information on Ingredients
Product name / Reagent. Component ; CAS # ; % by Weight
EM QUANT ® Calcium Test Hydrogen Peroxide Urea; 124-43-6; 100%
EM QUANT ® Calcium Test SODIUM HYDROXIDE; 1310-73-2; 32%
WATER; 7732-18-5; 68%


Section 3. Hazards Identification
Physical State and Appearance
EM QUANT ® Calcium Test Solid. (Powder.)
EM QUANT ® Calcium Test Liquid.
Emergency Overview
EM QUANT ® Calcium Test WARNING!
OXIDIZER.
CONTACT WITH OTHER MATERIAL MAY CAUSE FIRE.
CAUSES EYE AND SKIN BURNS.
CAUSES RESPIRATORY TRACT IRRITATION.
CONTAINS MATERIAL WHICH CAUSES DAMAGE TO THE FOLLOWING ORGANS: LUNGS, RESPIRATORY TRACT, SKIN, EYE, LENS OR CORNEA.
MAY BE HARMFUL IF SWALLOWED.
EM QUANT ® Calcium Test DANGER!
POISON!
CAUSES SEVERE RESPIRATORY TRACT, EYE AND SKIN BURNS.
HARMFUL IF INHALED, ABSORBED THROUGH SKIN OR SWALLOWED.
CONTAINS MATERIAL WHICH CAUSES DAMAGE TO THE FOLLOWING ORGANS:LUNGS, RESPIRATORY TRACT, SKIN, EYE, LENS OR CORNEA.
Routes of Entry
EM QUANT ® Calcium Test Inhalation. Ingestion.
EM QUANT ® Calcium Test Inhalation. Ingestion.
Potential Acute Health Effects
Eyes
EM QUANT ® Calcium Test Hazardous in case of eye contact (corrosive). Causes eye burns.
EM QUANT ® Calcium Test Extremely hazardous in case of eye contact (corrosive). Causes severe eye burns.
Skin
EM QUANT ® Calcium Test Hazardous in case of skin contact (corrosive). Skin contact produces burns.
EM QUANT ® Calcium Test Extremely hazardous in case of skin contact (corrosive). Skin contact produces severe burns. Hazardous in case of skin contact (permeator).
Inhalation
EM QUANT ® Calcium Test Hazardous in case of inhalation (lung irritant).
EM QUANT ® Calcium Test Extremely hazardous in case of inhalation (lung corrosive). Hazardous in case of inhalation.
Ingestion
EM QUANT ® Calcium Test May be hazardous in case of ingestion.
EM QUANT ® Calcium Test Hazardous in case of ingestion.
Potential Chronic Health Effects
Carcinogenic Effects
EM QUANT ® Calcium Test This material is not known to cause cancer in animals or humans.
EM QUANT ® Calcium Test This material is not known to cause cancer in animals or humans.
Additional information See Toxicological Information (section 11)
Medical Conditions Aggravated by Overexposure:
EM QUANT ® Calcium Test Repeated exposure of the eyes to a low level of dust can produce eye irritation. Repeated skin exposure can produce local skin destruction, or dermatitis. Repeated inhalation of dust can produce varying degree of respiratory irritation or lung damage.
EM QUANT ® Calcium Test Repeated or prolonged contact with spray mist may produce chronic eye irritation and severe skin irritation. Repeated or prolonged exposure to spray mist may produce respiratory tract irritation leading to frequent attacks of bronchial infection. Repeated exposure to a highly toxic material may produce general deterioration of health by an accumulation in one or many human organs.


Section 4. First Aid Measures
Eye Contact
EM QUANT ® Calcium Test Check for and remove any contact lenses. In case of contact, immediately flush eyes with plenty of water for at least 15 minutes. Get medical attention immediately.
EM QUANT ® Calcium Test Check for and remove any contact lenses. In case of contact, immediately flush eyes with plenty of water for at least 15 minutes. Cold water may be used. Get medical attention immediately.
Skin Contact
EM QUANT ® Calcium Test In case of contact, immediately flush skin with plenty of water for at least 15 minutes while removing contaminated clothing and shoes. Wash clothing before reuse. Thoroughly clean shoes before reuse. Get medical attention immediately.
EM QUANT ® Calcium Test In case of contact, immediately flush skin with plenty of water for at least 15 minutes while removing contaminated clothing and shoes. Cold water may be used. Wash clothing before reuse. Thoroughly clean shoes before reuse. Get medical attention immediately.
Inhalation
EM QUANT ® Calcium Test If inhaled, remove to fresh air. If not breathing, give artificial respiration. If breathing is difficult, give oxygen. Get medical attention immediately.
EM QUANT ® Calcium Test If inhaled, remove to fresh air. If not breathing, give artificial respiration. If breathing is difficult, give oxygen. Get medical attention immediately.
Ingestion
EM QUANT ® Calcium Test Do NOT induce vomiting unless directed to do so by medical personnel. Never give anything by mouth to an unconscious person. If large quantities of this material are swallowed, call a physician immediately. Loosen tight clothing such as a collar, tie, belt or waistband.
EM QUANT ® Calcium Test If swallowed, do not induce vomiting unless directed to do so by medical personnel. Never give anything by mouth to an unconscious person. Loosen tight clothing such as a collar, tie, belt or waistband. Get medical attention immediately.


Section 5. Fire Fighting Measures
Flammability of the Product
EM QUANT ® Calcium Test May be combustible at high temperature.
EM QUANT ® Calcium Test May be combustible at high temperature.
Auto-ignition Temperature
EM QUANT ® Calcium Test 359.9°C (679.8°F)
EM QUANT ® Calcium Test Not available.
Flash Points
EM QUANT ® Calcium Test Not available.
EM QUANT ® Calcium Test Not available.
Flammable Limits
EM QUANT ® Calcium Test Not available.
EM QUANT ® Calcium Test Not available.
Products of Combustion
EM QUANT ® Calcium Test These products are carbon oxides (CO, CO2), nitrogen oxides (NO, NO2...).
EM QUANT ® Calcium Test Some metallic oxides.
Fire Hazards in Presence of Various Substances
EM QUANT ® Calcium Test Not available.
EM QUANT ® Calcium Test Not available.
Explosion Hazards in Presence of Various Substances
EM QUANT ® Calcium Test Risks of explosion of the product in presence of static discharge: No.

Risks of explosion of the product in presence of mechanical impact: No.
EM QUANT ® Calcium Test Risks of explosion of the product in presence of static discharge: No.

Risks of explosion of the product in presence of mechanical impact: No.
Fire Fighting Media
and Instructions
EM QUANT ® Calcium Test Do not use water jet. Use flooding quantities of water. Avoid contact with organic materials.
EM QUANT ® Calcium Test SMALL FIRE: Use DRY chemical powder.
LARGE FIRE: Use water spray, fog or foam. Do not use water jet.
Protective Clothing (Fire)
EM QUANT ® Calcium Test Be sure to use an approved/certified respirator or equivalent.
EM QUANT ® Calcium Test Be sure to use an approved/certified respirator or equivalent.
Special Remarks on Fire Hazards
EM QUANT ® Calcium Test CONTACT WITH OTHER MATERIAL MAY CAUSE FIRE.
EM QUANT ® Calcium Test Not available.
Special Remarks on Explosion Hazards
EM QUANT ® Calcium Test Not available.
EM QUANT ® Calcium Test Not available.


Section 6. Accidental Release Measures
Small Spill and Leak
EM QUANT ® Calcium Test Use appropriate tools to put the spilled solid in a convenient waste disposal container.
EM QUANT ® Calcium Test Dilute with water and mop up, or absorb with an inert dry material and place in an appropriate waste disposal container.
Large Spill and Leak
EM QUANT ® Calcium Test Stop leak if without risk. Do not get water inside container. Avoid contact with a combustible material (wood, paper, oil, clothing...). Keep substance damp using water spray. Do not touch spilled material. Use water spray to reduce vapors. Prevent entry into sewers, basements or confined areas; dike if needed. Eliminate all ignition sources. Call for assistance on disposal. Finish cleaning by spreading water on the contaminated surface and allow to evacuate through the sanitary system.
EM QUANT ® Calcium Test Stop leak if without risk. Absorb with DRY earth, sand or other non-combustible material. Do not get water inside container. Do not touch spilled material. Use water spray curtain to divert vapor drift. Use water spray to reduce vapors. Prevent entry into sewers, basements or confined areas; dike if needed. Eliminate all ignition sources. Call for assistance on disposal. Be careful that the product is not present at a concentration level above TLV. Check TLV on the MSDS and with local authorities.
Spill Kit Information Reagent No. 1
No specific spill kit required for this product.
Reagent No. 2
The following EMD Chemicals Inc. SpillSolv ® absorbent is recommended for this product: SX1320 Caustic Treatment Kit


Section 7. Handling and Storage
Handling
EM QUANT ® Calcium Test Store in tightly closed container.
Do not get on skin or clothing.
Do not breathe dust.
Do not ingest.
EM QUANT ® Calcium Test Avoid contact with eyes, skin and clothing. Do not ingest. Do not breathe vapor or mist. Keep container closed. Use only with adequate ventilation. Wash thoroughly after handling.
Storage
EM QUANT ® Calcium Test Keep container in a cool, well-ventilated area. Separate from acids, alkalies, reducing agents and combustibles.
EM QUANT ® Calcium Test Keep container in a cool, well-ventilated area.


Section 8. Exposure Controls/Personal Protection
Engineering Controls
EM QUANT ® Calcium Test Use process enclosures, local exhaust ventilation, or other engineering controls to keep airborne levels below recommended exposure limits. If user operations generate dust, fume or mist, use ventilation to keep exposure to airborne contaminants below the exposure limit.
EM QUANT ® Calcium Test Provide exhaust ventilation or other engineering controls to keep the airborne concentrations of vapors below their respective occupational exposure limits. Ensure that eyewash stations and safety showers are proximal to the work-station location.
Personal Protection
Eyes
EM QUANT ® Calcium Test Splash goggles.
EM QUANT ® Calcium Test Face shield.
Body
EM QUANT ® Calcium Test Synthetic apron.
EM QUANT ® Calcium Test Full suit.
Respiratory
EM QUANT ® Calcium Test Dust respirator. Be sure to use an approved/certified respirator or equivalent. Wear appropriate respirator when ventilation is inadequate.
EM QUANT ® Calcium Test Vapor respirator. Be sure to use an approved/certified respirator or equivalent. Wear appropriate respirator when ventilation is inadequate.
Hands
EM QUANT ® Calcium Test Gloves.
EM QUANT ® Calcium Test Gloves.
Feet
EM QUANT ® Calcium Test Not applicable.
EM QUANT ® Calcium Test Boots.
Protective Clothing (Pictograms)
Face shield Full suit Vapor Respirator Gloves Boots
Personal Protection in Case of a Large Spill
EM QUANT ® Calcium Test Splash goggles. Full suit. Dust respirator. Boots. Gloves. A self-contained breathing apparatus should be used to avoid inhalation of the product. Suggested protective clothing might not be sufficient; consult a specialist BEFORE handling this product.
EM QUANT ® Calcium Test Splash goggles. Full suit. Vapor respirator. Boots. Gloves. A self-contained breathing apparatus should be used to avoid inhalation of the product. Suggested protective clothing might not be sufficient; consult a specialist BEFORE handling this product.
Product Name Exposure Limits
Hydrogen Peroxide Urea Not available.
Sodium Hydroxide ACGIH (United States).
CEIL: 2 mg/m3
OSHA (United States).
CEIL: 2 mg/m3
AUVA (Austria, 1995).
Spitzenbegrenzung: 4 mg/m3 8 times per shift, 5 minute(s).
TWA: 2 mg/m3 8 hour(s).
Belgium Minister of Labour (Belgium, 1998).
CEIL: 2 mg/m3
VL: 2 mg/m3 8 hour(s).
BAUA (Germany, 1997).
Spitzenbegrenzung: 2 mg/m3
TWA: 2 mg/m3 8 hour(s).
DK-Arbejdstylsinet (Denmark, 1996).
Loftværdi: 2 mg/m3
GV: 2 mg/m3 8 hour(s).
Tyterveyslaitos (Finland, 1998).
TWA: 2 mg/m3 8 hour(s).
INRS (France, 1996).
VME: 2 mg/m3 8 hour(s).
National Authority for Occupational Safety/Health (Ireland, 1999).
STEL: 2 mg/m3 15 minute(s).
Arbeidsinspectie (Netherlands, 1999).
MAC-C: 2 mg/m3
TGG 8 uur: 2 mg/m3 8 hour(s).
N-Arbeidstylsinet (Norway, 1996).
AN: 2 mg/m3 8 hour(s).
AFS (Sweden, 1996).
KTV: 2 mg/m3 15 minute(s).
EH40-OES (United Kingdom (UK), 1997).
STEL: 2 mg/m3 15 minute(s).
NIOSH REL (United States, 1994).
CEIL: 2 mg/m3
OSHA Final Rule (United States, 1989).
CEIL: 2 mg/m3
Water Not available.


Section 9. Physical and Chemical Properties
Odor
EM QUANT ® Calcium Test Not available.
EM QUANT ® Calcium Test Not available.
Color
EM QUANT ® Calcium Test Colorless.
EM QUANT ® Calcium Test Not available.
Physical State and Appearance
EM QUANT ® Calcium Test Solid. (Powder.)
EM QUANT ® Calcium Test Liquid.
Molecular Weight
EM QUANT ® Calcium Test 94.09 g/mole
EM QUANT ® Calcium Test Not applicable.
Molecular Formula
EM QUANT ® Calcium Test CH4N2OH2O2
EM QUANT ® Calcium Test Not applicable.
pH
EM QUANT ® Calcium Test Not available.
EM QUANT ® Calcium Test Not available.
Boiling/Condensation Point
EM QUANT ® Calcium Test Not available.
EM QUANT ® Calcium Test The lowest known value is 99.9°C (211.8°F) (Water).
Melting/Freezing Point
EM QUANT ® Calcium Test 90.06 to 93.06°C (194.1 to 199.5°F)
EM QUANT ® Calcium Test May start to solidify at -0.1°C (31.8°F) based on data for: Water.
Critical Temperature
EM QUANT ® Calcium Test Not available.
EM QUANT ® Calcium Test Not available.
Specific Gravity
EM QUANT ® Calcium Test 0.8 (Water = 1)
EM QUANT ® Calcium Test The only known value is 2.13 (Water = 1) (Sodium Hydroxide).
Vapor Pressure
EM QUANT ® Calcium Test Not available.
EM QUANT ® Calcium Test Not available.
Vapor Density
EM QUANT ® Calcium Test Not available.
EM QUANT ® Calcium Test Not available.
Volatility
EM QUANT ® Calcium Test Not available.
EM QUANT ® Calcium Test Not available.
Odor Threshold
EM QUANT ® Calcium Test Not available.
EM QUANT ® Calcium Test Not available.
Evaporation Rate
EM QUANT ® Calcium Test Not available.
EM QUANT ® Calcium Test 0.36 (Water) compared to (n-BUTYL ACETATE=1)
VOC
EM QUANT ® Calcium Test Not available.
EM QUANT ® Calcium Test Not available.
Viscosity
EM QUANT ® Calcium Test Not available.
EM QUANT ® Calcium Test Not available.
LogKow
EM QUANT ® Calcium Test Not available.
EM QUANT ® Calcium Test Not available.
Ionicity (in Water)
EM QUANT ® Calcium Test Not available.
EM QUANT ® Calcium Test Not available.
Solubility
EM QUANT ® Calcium Test Not available.
EM QUANT ® Calcium Test Soluble in water.
Physical Chemical Comments
EM QUANT ® Calcium Test Not available.
EM QUANT ® Calcium Test Not available.


Section 10. Stability and Reactivity
Stability and Reactivity
EM QUANT ® Calcium Test The product is stable.
EM QUANT ® Calcium Test The product is stable.
Conditions of Instability
EM QUANT ® Calcium Test Not available.
EM QUANT ® Calcium Test Not available.
Incompatibility with Various Substances
EM QUANT ® Calcium Test Reactive with combustible materials, organic materials, metals, moisture.
EM QUANT ® Calcium Test Reactive with organic materials, metals, acids.
Rem/Incompatibility
EM QUANT ® Calcium Test Not available.
EM QUANT ® Calcium Test Not available.
Hazardous Decomposition Products
EM QUANT ® Calcium Test Not available.
EM QUANT ® Calcium Test Not available.
Hazardous Polymerization
EM QUANT ® Calcium Test Will not occur.
EM QUANT ® Calcium Test Will not occur.


Section 11. Toxicological Information
RTECS Number:
EM QUANT ® Calcium Test Not available.
Sodium Hydroxide WB4900000
Water ZC0110000
Toxicity
EM QUANT ® Calcium Test LD50: Not available.
LC50: Not available.
EM QUANT ® Calcium Test LD50: Not available.
LC50: Not available.
Chronic Effects on Humans Not available.
Acute Effects on Humans
EM QUANT ® Calcium Test Hazardous in case of eye contact (corrosive). Causes eye burns. Hazardous in case of skin contact (corrosive). Skin contact produces burns. Hazardous in case of inhalation (lung irritant). May be hazardous in case of ingestion.
EM QUANT ® Calcium Test Extremely hazardous in case of eye contact (corrosive). Causes severe eye burns. Extremely hazardous in case of skin contact (corrosive). Skin contact produces severe burns. Hazardous in case of skin contact (permeator). Extremely hazardous in case of inhalation (lung corrosive). Hazardous in case of inhalation. Hazardous in case of ingestion.
Special Remarks on Toxicity
EM QUANT ® Calcium Test Not available.
EM QUANT ® Calcium Test Not available.
Special Remarks on Chronic Effects on Humans
EM QUANT ® Calcium Test Not available.
EM QUANT ® Calcium Test Not available.
Special Remarks on Other Toxic Effects on Humans
EM QUANT ® Calcium Test Not available.
EM QUANT ® Calcium Test Not available.
Synergetic Products (Toxicologically)
EM QUANT ® Calcium Test Not available.
EM QUANT ® Calcium Test Not available.
Irritancy
EM QUANT ® Calcium Test Draize Test: Not available.
EM QUANT ® Calcium Test Draize Test: Not available.
Sensitization
EM QUANT ® Calcium Test Not available.
EM QUANT ® Calcium Test Slightly hazardous in case of inhalation (lung sensitizer).
Carcinogenic Effects
EM QUANT ® Calcium Test This material is not known to cause cancer in animals or humans.
EM QUANT ® Calcium Test This material is not known to cause cancer in animals or humans.
Toxicity to Reproductive System
EM QUANT ® Calcium Test Not available.
EM QUANT ® Calcium Test Not available.
Teratogenic Effects
EM QUANT ® Calcium Test Not available.
EM QUANT ® Calcium Test Not available.
Mutagenic Effects
EM QUANT ® Calcium Test Not available.
EM QUANT ® Calcium Test Not available.


Section 12. Ecological Information
Ecotoxicity
EM QUANT ® Calcium Test Not available.
EM QUANT ® Calcium Test Not available.
BOD5 and COD
EM QUANT ® Calcium Test Not available.
EM QUANT ® Calcium Test Not available.
Biodegradable/OECD
EM QUANT ® Calcium Test Not available.
EM QUANT ® Calcium Test Not available.
Mobility
EM QUANT ® Calcium Test Not available.
EM QUANT ® Calcium Test Not available.
EM QUANT ® Calcium Test Possibly hazardous short term degradation products are not likely. However, long term degradation products may arise.
EM QUANT ® Calcium Test Possibly hazardous short term degradation products are not likely. However, long term degradation products may arise.
Toxicity of the Products of Biodegradation
EM QUANT ® Calcium Test The products of degradation are less toxic than the product itself.
EM QUANT ® Calcium Test The products of degradation are less toxic than the product itself.
Special Remarks on the Products of Biodegradation
EM QUANT ® Calcium Test Not available.
EM QUANT ® Calcium Test Not available.


Section 13. Disposal Considerations
EPA Waste Number
EM QUANT ® Calcium Test Not available.
EM QUANT ® Calcium Test D002
Treatment
EM QUANT ® Calcium Test Material does not have an EPA Waste Number and is not a listed waste, however consultation with a permitted waste disposal site (TSD) should be accomplished. Always contact a permitted waste disposal (TSD) to assure compliance with all current local, state, and Federal Regulations.
EM QUANT ® Calcium Test Specified Technology - Neutralize to pH 6-9. Contact your local permitted waste disposal site (TSD) for permissible treatment sites. Always contact a permitted waste disposal (TSD) to assure compliance with all current local, state, and Federal Regulations.


Section 14. Transport Information
DOT Classification Proper Shipping Name: CHEMICAL KIT
Hazard Class: 9
UN number: UN3316
Packing Group: II
RQ: Not applicable.
TDG Classification Not available.
IMO/IMDG Classification Proper Shipping Name: CHEMICAL KIT
Hazard Class: 9
UN number: UN3316
Packing Group: II
RQ: Not applicable.
ICAO/IATA Classification Proper Shipping Name: CHEMICAL KIT
Hazard Class: 9
UN number: UN3316
Packing Group: II
RQ: Not applicable.


Section 15. Regulatory Information
U.S. Federal Regulations
EM QUANT ® Calcium Test TSCA 8(b) inventory: Hydrogen Peroxide Urea
EM QUANT ® Calcium Test TSCA 8(b) inventory: Sodium Hydroxide; Water
EM QUANT ® Calcium Test SARA 302/304/311/312 extremely hazardous substances: No products were found.
SARA 302/304 emergency planning and notification: No products were found.
SARA 302/304/311/312 hazardous chemicals: Hydrogen Peroxide Urea
SARA 311/312 MSDS distribution - chemical inventory - hazard identification: Hydrogen Peroxide Urea: Fire Hazard, reactive, Immediate (Acute) Health Hazard
EM QUANT ® Calcium Test SARA 302/304/311/312 extremely hazardous substances: No products were found.
SARA 302/304 emergency planning and notification: No products were found.
SARA 302/304/311/312 hazardous chemicals: Sodium Hydroxide
SARA 311/312 MSDS distribution - chemical inventory - hazard identification: Sodium Hydroxide: Immediate (Acute) Health Hazard
EM QUANT ® Calcium Test SARA 313 toxic chemical notification and release reporting: No products were found.
EM QUANT ® Calcium Test SARA 313 toxic chemical notification and release reporting: No products were found.
EM QUANT ® Calcium Test Clean Water Act (CWA) 307: No products were found.
EM QUANT ® Calcium Test Clean Water Act (CWA) 307: No products were found.
EM QUANT ® Calcium Test Clean Water Act (CWA) 311: No products were found.
EM QUANT ® Calcium Test Clean Water Act (CWA) 311: Sodium Hydroxide
EM QUANT ® Calcium Test Clean air act (CAA) 112 accidental release prevention: No products were found.
EM QUANT ® Calcium Test Clean air act (CAA) 112 accidental release prevention: No products were found.
EM QUANT ® Calcium Test Clean air act (CAA) 112 regulated flammable substances: No products were found.
EM QUANT ® Calcium Test Clean air act (CAA) 112 regulated flammable substances: No products were found.
EM QUANT ® Calcium Test Clean air act (CAA) 112 regulated toxic substances: No products were found.
EM QUANT ® Calcium Test Clean air act (CAA) 112 regulated toxic substances: No products were found.
WHMIS (Canada)
EM QUANT ® Calcium Test CLASS C: Oxidizing material.
CLASS E: Corrosive solid.
EM QUANT ® Calcium Test Class D-1B: Material causing immediate and serious toxic effects (TOXIC).
Class D-2A: Material causing other toxic effects (VERY TOXIC).
CLASS E: Corrosive liquid.
EM QUANT ® Calcium Test CEPA NDSL: Hydrogen Peroxide Urea
EM QUANT ® Calcium Test CEPA DSL: Sodium Hydroxide; Water
This product has been classifed in accordance with the hazard criteria of the Controlled Product Regulations and the MSDS contains all required information.
International Regulations
EINECS Hydrogen Peroxide Urea 204-701-4
SODIUM HYDROXIDE 215-185-5
WATER 231-791-2
DSCL (EEC)
EM QUANT ® Calcium Test R34- Causes burns.
EM QUANT ® Calcium Test R35- Causes severe burns.
International Lists
EM QUANT ® Calcium Test Australia (NICNAS): Hydrogen Peroxide Urea

Korea (TCCL): Hydrogen Peroxide Urea

Philippines (RA6969): Hydrogen Peroxide Urea
EM QUANT ® Calcium Test Australia (NICNAS): Sodium Hydroxide; Water

Japan (MITI): Sodium Hydroxide; Water

Korea (TCCL): Sodium Hydroxide; Water

Philippines (RA6969): Sodium Hydroxide; Water
China: No products were found.
State Regulations
EM QUANT ® Calcium Test New Jersey: Hydrogen Peroxide Urea
EM QUANT ® Calcium Test Pennsylvania RTK: Sodium Hydroxide: (environmental hazard, generic environmental hazard)
Massachusetts RTK: Sodium Hydroxide
New Jersey: Sodium Hydroxide
EM QUANT ® Calcium Test California prop. 65: No products were found.
EM QUANT ® Calcium Test California prop. 65: No products were found.


Section 16. Other Information
National Fire Protection Association (U.S.A.)
1

Health
2
1
OXY
Fire Hazard

Reactivity

Specific Hazard
Other Special Considerations
EM QUANT ® Calcium Test Not available.
EM QUANT ® Calcium Test Not available.
Changed Since Last Revision +
Notice to Reader
The statements contained herein are based upon technical data that EMD Chemicals Inc. believes to be reliable, are offered for information purposes only and as a guide to the appropriate precautionary and emergency handling of the material by a properly trained person having the necessary technical skills. Users should consider these data only as a supplement to other information gathered by them and must make independent determinations of suitability and completeness of information from all sources to assure proper use, storage and disposal of these materials and the safety and health of employees and customers and the protection of the environment. EMD CHEMICALS INC. MAKES NO REPRESENTATION OR WARRANTY OF ANY KIND, EXPRESS OR IMPLIED, INCLUDING MERCHANTABILITY OR FITNESS FOR A PARTICULAR USE, WITH RESPECT TO THE INFORMATION HEREIN OR THE PRODUCT TO WHICH THE INFORMATION REFERS.