  • Image of Asphalt Institute Vacuum, Cannon Aivc Series Viscometers

    Asphalt Institute Vacuum, Cannon Aivc Series Viscometers

    Calibrated viscometers For measuring viscosity of highly viscous materials such as asphalt cement at 60°C (140°F) Meets ASTM D 2171 Applicable to materials with viscosity range of 42 to 5,800,000 poises With graduated capillary to extend viscosity range of viscometer Minimum sample size: 3 mL....
  • Image of BS/IP/MSL Miniature Suspended Level Viscometers

    BS/IP/MSL Miniature Suspended Level Viscometers

    Calibrated viscometers For measuring kinematic viscosity of transparent Newtonian liquids Meets ASTM D 445 and ISO 3104 Specifications conform to ASTM D 446 and ISO 3105. Precision:±0.2%. Minimum sample volume:4 mL. Requires liquid bath of 305 mm (12”). Includes certificate of calibration and...
  • Image of BS/IP/RF U-Tube Reversed Flow Viscometers

    BS/IP/RF U-Tube Reversed Flow Viscometers

    Calibrated viscometers For measuring kinematic viscosity of opaque Newtonian liquids Meets ASTM D 445 and ISO 3104 Specifications conform to ASTM D 446 and ISO 3105. Precision: ±0.3%. Minimum sample volume: 7 mL. Requires liquid bath depth of 280 mm (11"). Includes certificate of calibration...
  • Image of BS/IP/SL Suspended Level Viscometer

    BS/IP/SL Suspended Level Viscometer

    Calibrated viscometers For measuring kinematic viscosity of transparent Newtonian liquids Meets ASTM D 445 and ISO 3104 Specifications conform to ASTM D 446 and ISO 3105 Precision: ±0.2% Minimum sample volume: 11 mL. Requires liquid bath depth of 250 mm (10”). Includes certificate of...
  • Image of BS/IP/SL(S) Viscometers

    BS/IP/SL(S) Viscometers

    Calibrated viscometers For measuring kinematic viscosity of transparent Newtonian liquids Meets ASTM D 445 and ISO 3104 Specifications conform to ASTM D 446 and ISO 3105. Precision: ±0.2%. Minimum sample volume:10 mL. Requires liquid bath depth of 230 mm (9”). Includes certificate of...
  • Image of BS/U/M Miniature U-Tube

    BS/U/M Miniature U-Tube

    Calibrated viscometers For measuring kinematic viscosity of transparent Newtonian liquids Meets ASTM D 445 and ISO 3104 Precision: ±0.2% Specifications conform to ASTM D 446 and ISO 3105. Minimum sample volume: 2 mL. Requires liquid bath depth of 230 mm (9"). Includes certificate of...
  • Image of BS/U Tube Viscometers

    BS/U Tube Viscometers

    Calibrated viscometers For measuring kinematic viscosity of transparent Newtonian liquids Meets ASTM D 445 and ISO 3104 Specifications conform to ASTM D 446 and ISO 3105. Precision: ±0.2%. Minimum sample volume: 7 mL in sizes A to C; 12 mL in sizes D to F ; 23 mL in sizes G and H. Requires liquid...
  • Image of Cannon-Fenske Series Viscometers

    Cannon-Fenske Series Viscometers

    Cannon Fenske Routine, CFRU (Uncalibrated) & CFRC (Calibrated) Viscometers For measurement of kinematic viscosity of transparent Newtonian liquids, particularly petroleum products or lubricants Meets ASTM D 445 and ISO 3104 requirements Specifications conform to ASTM D 446 and ISO 3105...
  • Image of Cannon Four Bulb Shear Dilution Viscometers

    Cannon Four Bulb Shear Dilution Viscometers

    Four Bulb Shear Dilution- Five-fold Dilution Type, Cannon CUSDC-11 Series For measurement of intrinsic viscosities extrapolated to zero shear rate Provides five-fold range of shear rates Design gives extra mechanical strength Negligible kinetic energy correction Precision: ±0.2% Provided...
  • Image of Cannon-Manning Semi-Micro, Cannon CMSMC Series Viscometers

    Cannon-Manning Semi-Micro, Cannon CMSMC Series Viscometers

    Calibrated Viscometers For measurement of kinematic viscosity of small samples of transparent Newtonian liquids, particularly petroleum products or lubricants Meets ASTM D 445 requirements Precision: ±0.2% Specifications conform with ASTM Standard D 446. Minimum sample volume: 1.0 mL. Sizes...
  • Image of Cannon-Manning Vacuum, Cannon CMVC Series Viscometers

    Cannon-Manning Vacuum, Cannon CMVC Series Viscometers

    Calibrated viscometers For measurement of viscosity of highly viscous materials such as asphalt cement at 140°F Meets ASTM Standard D 2171 Applicable to materials with viscosity range of 0.036 to 80,000 poise. Vacuum of 300 mm Hg is applied to small arm with timing bulbs; two bulbs are...
  • Image of Cannon-Ubbelohde, CUU And CUC Series Viscometers

    Cannon-Ubbelohde, CUU And CUC Series Viscometers

    Uncalibrated and Calibrated Viscometers Suspended level viscometer for measurement of kinematic viscosity of transparent Newtonian liquids Also used for evaluating jet fuels and hydraulic fluids Meets ASTM D 445 and D 446, as well as ISO 3104 and 3105 requirements Suitable for use at temperatures...
  • Image of Cannon-Ubbelohde UBU And UBC Series

    Cannon-Ubbelohde UBU And UBC Series

    Uncalibrated and Calibrated Viscometers Measure kinematic viscosity of transparent Newtonian liquids by suspended level principle Meets ASTM D 445 and D 446 and ISO 3104 and 3105 requirements. Precision: ±0.2% Similar to Cannon-Ubbelohde but less rugged in design. Includes instruction sheet....
  • Image of Modified Koppers Vacuum, Cannon Mkvc Series Viscometers

    Modified Koppers Vacuum, Cannon Mkvc Series Viscometers

    Calibrated viscometers For measuring viscosity of asphalt at 60°C (140°F) Meets ASTM Standard D 2171 Applicable to materials with viscosity range of 42 to 200,000 poises. Two-piece design, with sample reservoir and calibrated capillary Vacuum of 300 mm Hg must be applied to top of capillary tube....
  • Image of Semi-Micro, Cannon CUSMC Series Viscometer

    Semi-Micro, Cannon CUSMC Series Viscometer

    Calibrated For measurement of kinematic viscosity of small samples of transparent Newtonian liquids Meets ASTM Standard D 445; specifications conform with ASTM Standard D 446 Viscometer constant is same at all temperatures Initial sample can be diluted to as much as 20 mL for intrinsic viscosity...
  • Image of Viscometer Ostwald Oil

    Viscometer Ostwald Oil

    Item #: 9724X80
    Made with borosilicate glass Without stopcock Time of outflow for water at room temperature: 60 to 100 seconds Minimum sample: 5 mL