Key features of GC columns include their use of molecular sieve columns, which offer high efficiency in separating small molecules like gases and volatile organic compounds. Integrating fused silica in these columns improves their thermal stability and reduces reactivity, ensuring accurate and consistent results. The columns' design maximizes the interaction between the stationary phase and the analyzed compounds, leading to more precise identification and quantification.
In practical terms, users benefit from the columns' reliability in various applications, including environmental testing, forensic analysis, and quality control in manufacturing. Their design and material composition makes them a valuable asset in any laboratory focused on gas chromatography.
-
low-polarity phase; Crossbond 1,4-bis(dimethylsiloxy)phenylene dimethyl polysiloxane Rxi fused silica capillary GC columns were designed specifically to be the best columns available, for exceptional inertness, ultra-low bleed, and reproducible retention and selectivity. In addition to…
-
low-polarity phase; Crossbond diphenyl dimethyl polysiloxane General purpose columns for drugs, solvent impurities, pesticides, hydrocarbons, PCB congeners (e.g., Aroclor mixes), essential oils, semivolatiles. Column specifically tested for low-bleed performance. Temperature range:…
-
Equivalent to USP G43 phase Temperature range -60°C to 330/350°C
-
low-polarity phase; Crossbond 5% diphenyl/95% dimethyl polysiloxane Active basic compounds that otherwise require derivatization, or an alternative analytical technique, can be analyzed on an Rtx-5 Amine column. The tubing surface is chemically altered to reduce tailing of basic compounds,…
-
low-polarity phase; Crossbond diphenyl dimethyl polysiloxane Rxi fused silica capillary GC columns were designed specifically to be the best columns available, for exceptional inertness, ultra-low bleed, and reproducible retention and selectivity. In addition to outstanding performance, this…
-
Glass Empty Column, 2mm i.d., 1/4in o.d., 3 ft for AutoSystem GC (on column)
-
Extend column lifetime. Excellent inertness—obtain lower detection limits for active compounds. Sharper chromatographic peaks by utilizing retention gap technology. Maximum temperature: 360°C
-
Elite-1 capillary column, 15m x 0.53mm, 3.00µm
PerkinElmerEquivalent to USP G1, G2 and G38 phases Temperature range -60°C to 350/400°C
-
2,3-di-acetoxy-6-O-tert-butyl dimethylsilyl beta cyclodextrin added into 14% cyanopropylphenyl/86% dimethyl polysiloxane By adding β or γ cyclodextrin to our bonded Rtx-1701 stationary phase, we greatly enhance overall utility and column lifetime for our chiral columns, compared to…
-
permethylated beta cyclodextrin added into 14% cyanopropylphenyl/86% dimethyl polysiloxane By adding β or γ cyclodextrin to our bonded Rtx-1701 stationary phase, we greatly enhance overall utility and column lifetime for our chiral columns, compared to columns that have pure…
-
Undeactivated Fused Silica Tubing
Agilent TechnologiesUndeactivated tubing or bare fused silica is commonly used for capillary electrophoresis. It can also be used for transfer lines and other applications where inertness is not critical. Agilent Technologies products are intended for sale/shipment within the US only. International customers…
-
polar phase; Crossbond cyanopropylmethyl phenylmethyl polysiloxane The cyanopropyl-containing Rtx-225 phase is slightly less polar than bonded polyethylene glycol (PEG) phases, but it can be used for many of the same applications. Improvements to the Rtx-225 polymer have increased thermal…
-
General purpose column has a PTFE stopcock and a top outer joint. Glass wool (not supplied) is used to support column packing. Column is constructed using MEDIUM WALL TUBING. Can be used as a gravity eluted column or a flash column (as described by W.C. Still, M. Kahn and A. Mitra of Columbia…
-
DB-35ms Ultra Inert Columns
Agilent TechnologiesAgilent J&W DB-35ms Ultra Inert is a mid-polar column, for applications where different selectivity is needed for enhanced separations, including pesticide analysis and drugs of abuse testing. DB-35ms Ultra Inert quantifies components at a lower level, with broader linearity and optimized…
-
DB-624
Agilent TechnologiesGC capillary columns are typically wound on 7 inch cages that fit into standard-sized GCs like the 6890. The 6850 GC has a smaller oven which requires the use of columns wound on a smaller cage diameter. Specifically designed for the analysis of volatile priority pollutants No…
-
5% Phenyl Polysilphenylene-siloxane High temperature General Purpose GC column - suitable for over 80% of all routine analyses performed by gas chromatography Very Low Bleed - ideal for trace analysis Non-Polar Extremely inert Ideal for GC-MS Application Areas: …
-
CarboBlack Columns
RestekGraphitized carbon black offers unique selectivity and very little adsorption for alcohol analyses. Two types of CarboBlack supports are available, CarboBlack B and CarboBlack C. CarboBlack B support, with its higher surface area, can hold up to a 10% loading of a nonsilicone liquid phase.…
-
Temperature range 40°C to 360°C Equivalent to USP G3
-
Elite 624 capillary column 30m x 0.32mm, 1.80µm
PerkinElmerTemperature range -20°C to 240°C Equivalent to USP G43 phase
-
OPTIMA® 1 Capillary Columns
MACHEREY-NAGELOPTIMA® 1 Capillary columns for GC Features 100 % dimethylpolysiloxane · USP G1 / G2 / G38 Nonpolar phase Separation of components according to boiling points Thick film columns ≥ 3 µm film are expecially recommended for solvent analysis. Low bleed…
-
HP-5
Agilent Technologies(5%-Phenyl)-methylpolysiloxane Non-polar Wide range of applications High temperature limits: -60° to 325°C isothermally, -60° to 350°C programmed. -60° to 300°C isothermally, -60° to 320°C programmed for 0.53 mm columns -60° to 260°/280°C…
-
midpolarity Crossbond phase Rtx-1701 is one of the more popular stationary phases used in capillary GC. The mix of cyano and phenyl functional groups increases the polarity and offers a different elution order relative to less polar Rtx-1 or Rtx-5 columns. An Rtx-1701 column is ideal for…
-
low- to midpolarity phase The unique polarity of "624" columns makes them ideal for analyses of volatile organic pollutants. Although the MXT-502.2 column is recommended in many methods, MXT-624 columns offer the best separation of the early-eluting gases. Application-specific…
-
high-polarity phase; Crossbond diphenyl dimethyl polysiloxane The Rtx-65TG phase resolves triglycerides by degree of unsaturation as well as by carbon number. Because of the chemistry required to achieve 370°C thermal stability, an Rtx-65TG column should not be used for the analyses of…
-
-
Elite 624 capillary column 60m x 0.25mm, 1.40µm
PerkinElmerTemperature range -20°C to 240°C Equivalent to USP G43 phase
-
Temperature range -60oC to 200 oC
-
Elite-WAX capillary column 15m x 0.45mm, 0.42µm
PerkinElmerTemperature range 20oC to 250 oC, Equivalent to USP G14, G15, G16, G20, G39.
-
Se-30 And Se-54
Agilent TechnologiesSE-30: 100% Dimethylpolysiloxane SE-54: (5%-Phenyl)(1%-Vinyl)-methylpolysiloxane Because SE series GC columns are not bonded or cross-linked, we do not recommend solvent rinsing. Agilent Technologies products are intended for sale/shipment within the US only. International customers…
-
General purpose column having a PTFE stopcock and a top Rodaviss® outer joint. Can be used as a gravity eluted column or a flash column (as described by W.C. Still, M. Kahn and A. Mitra of Columbia University in JOURNAL OF ORGANIC CHEMISTRY 43, 2923 [1978], and covered in U.S. Patent Number…
-
DB-Wax
Agilent TechnologiesPolyethylene glycol (PEG) Close equivalent to USP Phase G16 High polarity Lower temperature limit of 20°C is lowest of any bonded PEG phase; improves resolution of low boiling point analytes Column-to-column repeatability Bonded and cross-linked Solvent rinsable …
-
Proprietary cyclodextrin material added into 14% cyanopropylphenyl/86% dimethyl polysiloxane By adding β or γ cyclodextrin to our bonded Rtx-1701 stationary phase, we greatly enhance overall utility and column lifetime for our chiral columns, compared to columns that have pure…